Naglaa G. Fahmy, Hanaa Gamal Mohammed, L.M. Abd el-Hafez, Alaa Y. Abouelezz
{"title":"使用 ANSYS V.19 研究开口尺寸和位置对平板抗冲剪性能的影响","authors":"Naglaa G. Fahmy, Hanaa Gamal Mohammed, L.M. Abd el-Hafez, Alaa Y. Abouelezz","doi":"10.4028/p-IT6Xm6","DOIUrl":null,"url":null,"abstract":"To validate the accuracy of ANSYS V.19, an experimental model based on a previous study was used to determine the typical values of crack pattern, ultimate load, and deflection. The model was a flat slab with an internal column with dimensions of 1000 × 1000 × 100 mm³. Four groups used a slab with an edge column in parametric research. The first group studied the opening size relative to the column face. The second group of specimens studied opening sizes close to column corners. The third group consisted of four specimens: two had openings in front of the column face and two in front of the column corner to study how opening distance affected flat slab behaviour. The fourth group examined the optimum opening arrangement in slabs with two openings around the column. The findings showed that flat slab openings at the column corner had higher ultimate load capacity than those at the column face; however, increasing opening dimensions beyond the column dimension decreases punching shear capacity. If the column needs two openings, place them on opposite faces or near the corners; this minimizes ultimate load reduction.","PeriodicalId":45925,"journal":{"name":"International Journal of Engineering Research in Africa","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Studying the Effects of Opening Size and Location on Punching Shear Resistance of Flat Slabs Using ANSYS V.19\",\"authors\":\"Naglaa G. Fahmy, Hanaa Gamal Mohammed, L.M. Abd el-Hafez, Alaa Y. Abouelezz\",\"doi\":\"10.4028/p-IT6Xm6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To validate the accuracy of ANSYS V.19, an experimental model based on a previous study was used to determine the typical values of crack pattern, ultimate load, and deflection. The model was a flat slab with an internal column with dimensions of 1000 × 1000 × 100 mm³. Four groups used a slab with an edge column in parametric research. The first group studied the opening size relative to the column face. The second group of specimens studied opening sizes close to column corners. The third group consisted of four specimens: two had openings in front of the column face and two in front of the column corner to study how opening distance affected flat slab behaviour. The fourth group examined the optimum opening arrangement in slabs with two openings around the column. The findings showed that flat slab openings at the column corner had higher ultimate load capacity than those at the column face; however, increasing opening dimensions beyond the column dimension decreases punching shear capacity. If the column needs two openings, place them on opposite faces or near the corners; this minimizes ultimate load reduction.\",\"PeriodicalId\":45925,\"journal\":{\"name\":\"International Journal of Engineering Research in Africa\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2023-12-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Engineering Research in Africa\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/p-IT6Xm6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Engineering Research in Africa","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-IT6Xm6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Studying the Effects of Opening Size and Location on Punching Shear Resistance of Flat Slabs Using ANSYS V.19
To validate the accuracy of ANSYS V.19, an experimental model based on a previous study was used to determine the typical values of crack pattern, ultimate load, and deflection. The model was a flat slab with an internal column with dimensions of 1000 × 1000 × 100 mm³. Four groups used a slab with an edge column in parametric research. The first group studied the opening size relative to the column face. The second group of specimens studied opening sizes close to column corners. The third group consisted of four specimens: two had openings in front of the column face and two in front of the column corner to study how opening distance affected flat slab behaviour. The fourth group examined the optimum opening arrangement in slabs with two openings around the column. The findings showed that flat slab openings at the column corner had higher ultimate load capacity than those at the column face; however, increasing opening dimensions beyond the column dimension decreases punching shear capacity. If the column needs two openings, place them on opposite faces or near the corners; this minimizes ultimate load reduction.
期刊介绍:
"International Journal of Engineering Research in Africa" is a peer-reviewed journal which is devoted to the publication of original scientific articles on research and development of engineering systems carried out in Africa and worldwide. We publish stand-alone papers by individual authors. The articles should be related to theoretical research or be based on practical study. Articles which are not from Africa should have the potential of contributing to its progress and development.