晚期黑色素瘤患者血浆达卡巴嗪水平的定量分析:液相色谱-串联质谱性能分析。

IF 1.3 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Scandinavian Journal of Clinical & Laboratory Investigation Pub Date : 2023-12-01 Epub Date: 2024-01-24 DOI:10.1080/00365513.2023.2297356
Wenhan Cheng, John Liu, Bryan Jackson
{"title":"晚期黑色素瘤患者血浆达卡巴嗪水平的定量分析:液相色谱-串联质谱性能分析。","authors":"Wenhan Cheng, John Liu, Bryan Jackson","doi":"10.1080/00365513.2023.2297356","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to develop a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying dacarbazine levels in the plasma of advanced melanoma patients, followed by an assessment of its analytical capabilities. The research encompassed the design of a high-performance liquid chromatography (HPLC) system, with the quantitative analysis performed using the multiple reaction monitoring (MRM) techniques and specific ion transition: 181.0 > 152.5 for dacarbazine and 187.1 > 158.6 for the internal standard (IS), dacarbazine-D6. The validation of the method involved an evaluation of parameters including linearity, detection limit, precision, and accuracy. Notably, the linear range extended from 10 to 1,000 µg/L for dacarbazine, and the method exhibited a detection limit of 10 µg/L. The method's precision, indicated by within-run and between-run coefficients of variation (CV), both being ≤4.2% and ≤8.3%, respectively. Furthermore, the accuracy of measurements, ranging from 86.1% to 99.4%, underscored the method's reliability. In clinical application, the dacarbazine levels of healthy control (<i>n</i> = 20) were 0.6 ± 0.02 μg/L; 770.9 ± 203.2 μg/mL in early-stage-melanoma patients (<i>n</i> = 22), and 588.7 ± 153.2 μg/mL in advanced melanoma patients (<i>n</i> = 25). The results serve as clinical evidence showing that long-term dacarbazine treatment affects the metabolism of dacarbazine.</p>","PeriodicalId":21474,"journal":{"name":"Scandinavian Journal of Clinical & Laboratory Investigation","volume":" ","pages":"614-619"},"PeriodicalIF":1.3000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantifying plasma dacarbazine levels in advanced melanoma patients: a liquid chromatography-tandem mass spectrometry performance analysis.\",\"authors\":\"Wenhan Cheng, John Liu, Bryan Jackson\",\"doi\":\"10.1080/00365513.2023.2297356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to develop a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying dacarbazine levels in the plasma of advanced melanoma patients, followed by an assessment of its analytical capabilities. The research encompassed the design of a high-performance liquid chromatography (HPLC) system, with the quantitative analysis performed using the multiple reaction monitoring (MRM) techniques and specific ion transition: 181.0 > 152.5 for dacarbazine and 187.1 > 158.6 for the internal standard (IS), dacarbazine-D6. The validation of the method involved an evaluation of parameters including linearity, detection limit, precision, and accuracy. Notably, the linear range extended from 10 to 1,000 µg/L for dacarbazine, and the method exhibited a detection limit of 10 µg/L. The method's precision, indicated by within-run and between-run coefficients of variation (CV), both being ≤4.2% and ≤8.3%, respectively. Furthermore, the accuracy of measurements, ranging from 86.1% to 99.4%, underscored the method's reliability. In clinical application, the dacarbazine levels of healthy control (<i>n</i> = 20) were 0.6 ± 0.02 μg/L; 770.9 ± 203.2 μg/mL in early-stage-melanoma patients (<i>n</i> = 22), and 588.7 ± 153.2 μg/mL in advanced melanoma patients (<i>n</i> = 25). The results serve as clinical evidence showing that long-term dacarbazine treatment affects the metabolism of dacarbazine.</p>\",\"PeriodicalId\":21474,\"journal\":{\"name\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"volume\":\" \",\"pages\":\"614-619\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scandinavian Journal of Clinical & Laboratory Investigation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/00365513.2023.2297356\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Clinical & Laboratory Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365513.2023.2297356","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在开发一种稳健的液相色谱-串联质谱(LC-MS/MS)方法,用于定量检测晚期黑色素瘤患者血浆中达卡巴嗪的水平,并对其分析能力进行评估。这项研究包括设计一个高效液相色谱(HPLC)系统,利用多反应监测(MRM)技术和特定离子转换进行定量分析:达卡巴嗪的离子转换率为 181.0 > 152.5,内标(IS)达卡巴嗪-D6 的离子转换率为 187.1 > 158.6。该方法的验证包括对线性、检测限、精密度和准确度等参数的评估。值得注意的是,达卡巴嗪的线性范围为 10 至 1,000 µg/L,方法的检测限为 10 µg/L。该方法的精密度(以运行内变异系数和运行间变异系数表示)分别为≤4.2%和≤8.3%。此外,测量的准确度从 86.1%到 99.4%不等,突出了该方法的可靠性。在临床应用中,健康对照组(20 人)的达卡巴嗪水平为 0.6 ± 0.02 μg/L;早期黑色素瘤患者(22 人)的达卡巴嗪水平为 770.9 ± 203.2 μg/mL;晚期黑色素瘤患者(25 人)的达卡巴嗪水平为 588.7 ± 153.2 μg/mL。这些结果作为临床证据表明,长期达卡巴嗪治疗会影响达卡巴嗪的代谢。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quantifying plasma dacarbazine levels in advanced melanoma patients: a liquid chromatography-tandem mass spectrometry performance analysis.

The aim of this study was to develop a robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying dacarbazine levels in the plasma of advanced melanoma patients, followed by an assessment of its analytical capabilities. The research encompassed the design of a high-performance liquid chromatography (HPLC) system, with the quantitative analysis performed using the multiple reaction monitoring (MRM) techniques and specific ion transition: 181.0 > 152.5 for dacarbazine and 187.1 > 158.6 for the internal standard (IS), dacarbazine-D6. The validation of the method involved an evaluation of parameters including linearity, detection limit, precision, and accuracy. Notably, the linear range extended from 10 to 1,000 µg/L for dacarbazine, and the method exhibited a detection limit of 10 µg/L. The method's precision, indicated by within-run and between-run coefficients of variation (CV), both being ≤4.2% and ≤8.3%, respectively. Furthermore, the accuracy of measurements, ranging from 86.1% to 99.4%, underscored the method's reliability. In clinical application, the dacarbazine levels of healthy control (n = 20) were 0.6 ± 0.02 μg/L; 770.9 ± 203.2 μg/mL in early-stage-melanoma patients (n = 22), and 588.7 ± 153.2 μg/mL in advanced melanoma patients (n = 25). The results serve as clinical evidence showing that long-term dacarbazine treatment affects the metabolism of dacarbazine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
85
审稿时长
4-8 weeks
期刊介绍: The Scandinavian Journal of Clinical and Laboratory Investigation is an international scientific journal covering clinically oriented biochemical and physiological research. Since the launch of the journal in 1949, it has been a forum for international laboratory medicine, closely related to, and edited by, The Scandinavian Society for Clinical Chemistry. The journal contains peer-reviewed articles, editorials, invited reviews, and short technical notes, as well as several supplements each year. Supplements consist of monographs, and symposium and congress reports covering subjects within clinical chemistry and clinical physiology.
期刊最新文献
Analytical interference on measurement of immunoglobulins in monoclonal gammopathy. FlowDiff: a simple, flow cytometry-based approach for performing a leukocyte differential count. Reference intervals for 23 common biochemical parameters during pregnancy and the first six postpartum months. Prevalence of monoclonal proteins in patients with isolated hypogammaglobulinemia on serum protein electrophoresis. Challenges of preanalytical variables in erythrocyte sedimentation rate: a CUBE 30 touch evaluation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1