{"title":"球囊肺动脉瓣成形术:系统综述。","authors":"P. Syamasundar Rao","doi":"10.1016/j.ihj.2023.12.007","DOIUrl":null,"url":null,"abstract":"<div><p>There is conclusive evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvuloplasty (BPV) and at follow-up. Development of infundibular obstruction is seen in more severe PS cases and in older subjects. Reappearance of PS was observed in approximately 10 % of patients following BPV. The reasons for recurrence were found to be balloon/annulus ratio less than 1.2 and immediate post-BPV pulmonary valve peak gradients greater than 30 mmHg. Recurrent stenosis is successfully addressed by repeating BPV with lager balloons than used initially. Long-term results revealed continue relief of obstruction, but with development of pulmonary insufficiency, some patients requiring replacement of the pulmonary valve. It was concluded that BPV is the treatment of choice in the management valvar PS and that balloon/annuls ratio used for BPV should be lowered to 1.2 to 1.25. It was also suggested that strategies should be developed to prevent/reduce pulmonary insufficiency at long-term follow-up.</p></div>","PeriodicalId":13384,"journal":{"name":"Indian heart journal","volume":"76 2","pages":"Pages 86-93"},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143516/pdf/","citationCount":"0","resultStr":"{\"title\":\"Balloon pulmonary valvuloplasty: A systematic review\",\"authors\":\"P. Syamasundar Rao\",\"doi\":\"10.1016/j.ihj.2023.12.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>There is conclusive evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvuloplasty (BPV) and at follow-up. Development of infundibular obstruction is seen in more severe PS cases and in older subjects. Reappearance of PS was observed in approximately 10 % of patients following BPV. The reasons for recurrence were found to be balloon/annulus ratio less than 1.2 and immediate post-BPV pulmonary valve peak gradients greater than 30 mmHg. Recurrent stenosis is successfully addressed by repeating BPV with lager balloons than used initially. Long-term results revealed continue relief of obstruction, but with development of pulmonary insufficiency, some patients requiring replacement of the pulmonary valve. It was concluded that BPV is the treatment of choice in the management valvar PS and that balloon/annuls ratio used for BPV should be lowered to 1.2 to 1.25. It was also suggested that strategies should be developed to prevent/reduce pulmonary insufficiency at long-term follow-up.</p></div>\",\"PeriodicalId\":13384,\"journal\":{\"name\":\"Indian heart journal\",\"volume\":\"76 2\",\"pages\":\"Pages 86-93\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11143516/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian heart journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0019483223004765\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian heart journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019483223004765","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Balloon pulmonary valvuloplasty: A systematic review
There is conclusive evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvuloplasty (BPV) and at follow-up. Development of infundibular obstruction is seen in more severe PS cases and in older subjects. Reappearance of PS was observed in approximately 10 % of patients following BPV. The reasons for recurrence were found to be balloon/annulus ratio less than 1.2 and immediate post-BPV pulmonary valve peak gradients greater than 30 mmHg. Recurrent stenosis is successfully addressed by repeating BPV with lager balloons than used initially. Long-term results revealed continue relief of obstruction, but with development of pulmonary insufficiency, some patients requiring replacement of the pulmonary valve. It was concluded that BPV is the treatment of choice in the management valvar PS and that balloon/annuls ratio used for BPV should be lowered to 1.2 to 1.25. It was also suggested that strategies should be developed to prevent/reduce pulmonary insufficiency at long-term follow-up.
期刊介绍:
Indian Heart Journal (IHJ) is the official peer-reviewed open access journal of Cardiological Society of India and accepts articles for publication from across the globe. The journal aims to promote high quality research and serve as a platform for dissemination of scientific information in cardiology with particular focus on South Asia. The journal aims to publish cutting edge research in the field of clinical as well as non-clinical cardiology - including cardiovascular medicine and surgery. Some of the topics covered are Heart Failure, Coronary Artery Disease, Hypertension, Interventional Cardiology, Cardiac Surgery, Valvular Heart Disease, Pulmonary Hypertension and Infective Endocarditis. IHJ open access invites original research articles, research briefs, perspective, case reports, case vignette, cardiovascular images, cardiovascular graphics, research letters, correspondence, reader forum, and interesting photographs, for publication. IHJ open access also publishes theme-based special issues and abstracts of papers presented at the annual conference of the Cardiological Society of India.