过滤对 2% 环孢素眼药水有效浓度和无菌性的影响:质量改进的视角。

IF 1.2 Q4 PHARMACOLOGY & PHARMACY Journal of Pharmaceutical Health Care and Sciences Pub Date : 2023-12-27 DOI:10.1186/s40780-023-00323-9
Masakazu Ozaki, Toshihiko Kobayashi, Aki Fujinaga, Mitsuaki Nishioka, Kyoko Shikichi, Satoshi Okano, Yasuhito Sakai, Sayumi Fujii, Nobuaki Matsui, Miwako Takasago, Naoto Okada, Takahiro Yamasaki, Takashi Kitahara
{"title":"过滤对 2% 环孢素眼药水有效浓度和无菌性的影响:质量改进的视角。","authors":"Masakazu Ozaki, Toshihiko Kobayashi, Aki Fujinaga, Mitsuaki Nishioka, Kyoko Shikichi, Satoshi Okano, Yasuhito Sakai, Sayumi Fujii, Nobuaki Matsui, Miwako Takasago, Naoto Okada, Takahiro Yamasaki, Takashi Kitahara","doi":"10.1186/s40780-023-00323-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pharmaceutical companies do not sell formulations for all diseases; thus, healthcare workers have to treat some diseases by concocting in-hospital preparations. An example is the high-concentration 2% cyclosporine A (CyA) ophthalmic solution. Utilizing a filter in sterility operations is a general practice for concocting in-hospital preparations, as is the case for preparing a 2% CyA ophthalmic solution. However, whether filtering is appropriate concerning the active ingredient content and bacterial contamination according to the post-preparing quality control of a 2% CyA ophthalmic solution is yet to be verified.</p><p><strong>Methods: </strong>We conducted particle size, preparation concentration, and bacterial contamination studies to clarify aforementioned questions. First, we measured the particle size of CyA through a laser diffraction particle size distribution. Next, we measured the concentration after preparation with or without a 0.45-µm filter operation using an electrochemiluminescence immunoassay. Finally, bacterial contamination tests were conducted using an automated blood culture system to prepare a 2% CyA ophthalmic solution without a 0.45 μm filtering. Regarding the pore size of the filter in this study, it was set to 0.45 μm with reference to the book (the 6th edition) with recipes for the preparation of in-hospital preparations edited by the Japanese Society of Hospital Pharmacists.</p><p><strong>Results: </strong>CyA had various particle sizes; approximately 30% of the total particles exceeded 0.45 μm. The mean ± standard deviation of filtered and non-filtered CyA concentrations in ophthalmic solutions were 346.51 ± 170.76 and 499.74 ± 76.95ng/mL, respectively (p = 0.011). Regarding bacterial contamination tests, aerobes and anaerobes microorganisms were not detected in 14 days of culture.</p><p><strong>Conclusions: </strong>Due to the results of this study, the concentration of CyA may be reduced by using a 0.45-µm filter during the preparation of CyA ophthalmic solutions, and furthermore that the use of a 0.45-µm filter may not contribute to sterility when preparing CyA ophthalmic solutions.</p>","PeriodicalId":16730,"journal":{"name":"Journal of Pharmaceutical Health Care and Sciences","volume":"9 1","pages":"50"},"PeriodicalIF":1.2000,"publicationDate":"2023-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10752018/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of filtering on the effective concentration and sterility of a 2% cyclosporine ophthalmic solution: a quality improvement perspective.\",\"authors\":\"Masakazu Ozaki, Toshihiko Kobayashi, Aki Fujinaga, Mitsuaki Nishioka, Kyoko Shikichi, Satoshi Okano, Yasuhito Sakai, Sayumi Fujii, Nobuaki Matsui, Miwako Takasago, Naoto Okada, Takahiro Yamasaki, Takashi Kitahara\",\"doi\":\"10.1186/s40780-023-00323-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pharmaceutical companies do not sell formulations for all diseases; thus, healthcare workers have to treat some diseases by concocting in-hospital preparations. An example is the high-concentration 2% cyclosporine A (CyA) ophthalmic solution. Utilizing a filter in sterility operations is a general practice for concocting in-hospital preparations, as is the case for preparing a 2% CyA ophthalmic solution. However, whether filtering is appropriate concerning the active ingredient content and bacterial contamination according to the post-preparing quality control of a 2% CyA ophthalmic solution is yet to be verified.</p><p><strong>Methods: </strong>We conducted particle size, preparation concentration, and bacterial contamination studies to clarify aforementioned questions. First, we measured the particle size of CyA through a laser diffraction particle size distribution. Next, we measured the concentration after preparation with or without a 0.45-µm filter operation using an electrochemiluminescence immunoassay. Finally, bacterial contamination tests were conducted using an automated blood culture system to prepare a 2% CyA ophthalmic solution without a 0.45 μm filtering. Regarding the pore size of the filter in this study, it was set to 0.45 μm with reference to the book (the 6th edition) with recipes for the preparation of in-hospital preparations edited by the Japanese Society of Hospital Pharmacists.</p><p><strong>Results: </strong>CyA had various particle sizes; approximately 30% of the total particles exceeded 0.45 μm. The mean ± standard deviation of filtered and non-filtered CyA concentrations in ophthalmic solutions were 346.51 ± 170.76 and 499.74 ± 76.95ng/mL, respectively (p = 0.011). Regarding bacterial contamination tests, aerobes and anaerobes microorganisms were not detected in 14 days of culture.</p><p><strong>Conclusions: </strong>Due to the results of this study, the concentration of CyA may be reduced by using a 0.45-µm filter during the preparation of CyA ophthalmic solutions, and furthermore that the use of a 0.45-µm filter may not contribute to sterility when preparing CyA ophthalmic solutions.</p>\",\"PeriodicalId\":16730,\"journal\":{\"name\":\"Journal of Pharmaceutical Health Care and Sciences\",\"volume\":\"9 1\",\"pages\":\"50\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10752018/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Pharmaceutical Health Care and Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s40780-023-00323-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pharmaceutical Health Care and Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40780-023-00323-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

背景:制药公司并不出售治疗所有疾病的制剂,因此,医护人员必须通过调制院内制剂来治疗某些疾病。高浓度 2% 环孢素 A (CyA) 眼科溶液就是一个例子。在无菌操作中使用过滤器是配制院内制剂的一般做法,配制 2% CyA 眼科溶液也是如此。然而,根据 2% CyA 眼科溶液配制后的质量控制,就有效成分含量和细菌污染而言,过滤是否合适还有待验证:我们进行了粒度、制剂浓度和细菌污染研究,以澄清上述问题。首先,我们通过激光衍射粒度分布仪测量了 CyA 的粒度。然后,我们用电化学发光免疫测定法测定了使用或不使用 0.45 微米过滤器制备后的浓度。最后,我们使用自动血液培养系统进行了细菌污染测试,以制备未经 0.45 μm 过滤的 2% CyA 眼科溶液。关于本研究中过滤器的孔径,参照日本医院药剂师协会编辑的《院内制剂配制配方》一书(第 6 版),将其设定为 0.45 μm:CyA的颗粒大小不一,约30%的颗粒超过0.45微米。眼科溶液中过滤和非过滤 CyA 浓度的平均值(± 标准偏差)分别为 346.51 ± 170.76ng/mL 和 499.74 ± 76.95ng/mL (p = 0.011)。关于细菌污染测试,在 14 天的培养中未检测到需氧菌和厌氧菌微生物:根据本研究的结果,在配制 CyA 眼科溶液时使用 0.45-µm 过滤器可降低 CyA 的浓度,而且在配制 CyA 眼科溶液时使用 0.45-µm 过滤器可能不会导致无菌。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of filtering on the effective concentration and sterility of a 2% cyclosporine ophthalmic solution: a quality improvement perspective.

Background: Pharmaceutical companies do not sell formulations for all diseases; thus, healthcare workers have to treat some diseases by concocting in-hospital preparations. An example is the high-concentration 2% cyclosporine A (CyA) ophthalmic solution. Utilizing a filter in sterility operations is a general practice for concocting in-hospital preparations, as is the case for preparing a 2% CyA ophthalmic solution. However, whether filtering is appropriate concerning the active ingredient content and bacterial contamination according to the post-preparing quality control of a 2% CyA ophthalmic solution is yet to be verified.

Methods: We conducted particle size, preparation concentration, and bacterial contamination studies to clarify aforementioned questions. First, we measured the particle size of CyA through a laser diffraction particle size distribution. Next, we measured the concentration after preparation with or without a 0.45-µm filter operation using an electrochemiluminescence immunoassay. Finally, bacterial contamination tests were conducted using an automated blood culture system to prepare a 2% CyA ophthalmic solution without a 0.45 μm filtering. Regarding the pore size of the filter in this study, it was set to 0.45 μm with reference to the book (the 6th edition) with recipes for the preparation of in-hospital preparations edited by the Japanese Society of Hospital Pharmacists.

Results: CyA had various particle sizes; approximately 30% of the total particles exceeded 0.45 μm. The mean ± standard deviation of filtered and non-filtered CyA concentrations in ophthalmic solutions were 346.51 ± 170.76 and 499.74 ± 76.95ng/mL, respectively (p = 0.011). Regarding bacterial contamination tests, aerobes and anaerobes microorganisms were not detected in 14 days of culture.

Conclusions: Due to the results of this study, the concentration of CyA may be reduced by using a 0.45-µm filter during the preparation of CyA ophthalmic solutions, and furthermore that the use of a 0.45-µm filter may not contribute to sterility when preparing CyA ophthalmic solutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
29
审稿时长
8 weeks
期刊最新文献
Impact of pharmacist-led aminoglycoside stewardship: a 10-year observational study. The risk of upper gastrointestinal bleeding associated with concomitant proton pump inhibitor administration during dual antiplatelet therapy with aspirin and prasugrel: a retrospective single-center study. Efficacy of a melatonin receptor agonist and orexin receptor antagonists in preventing delirium symptoms in the olderly patients with stroke: a retrospective study. In-vivo evaluation of analgesic and anti-inflammatory activities of the 80% methanol extract of Acacia seyal stem bark in rodent models. Study on the chemical stability of β-lactam antibiotics in concomitant simple suspensions with magnesium oxide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1