Anamarija Jankulovska, Sasho Stojcevski, Igor Aluloski, Mile Tanturovski, Nevena Manevska, Ana Daneva Markova, Sinisa Stojanoski
{"title":"子宫内膜癌双侧 SLN 放射性胶体检测的预测因素","authors":"Anamarija Jankulovska, Sasho Stojcevski, Igor Aluloski, Mile Tanturovski, Nevena Manevska, Ana Daneva Markova, Sinisa Stojanoski","doi":"10.1055/s-0043-1777693","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction</b> Sentinel lymph node (SLN) mapping is an alternative method to conventional lymphadenectomy for nodal status assessment in patients with stage I/II endometrial carcinoma (EC). This study aimed to analyze the potential predictors of unsuccessful bilateral detection of SLN after the application of radiocolloid in EC. <b>Materials and Methods</b> A prospective, observational, cross-sectional study was performed on 41 patients with EC in preoperative stage I, who underwent SLN mapping after cervical application of 4mCi <sup>99m</sup> Tc-SENTI-SCINT. The demographic, clinical, and tumor-related data were obtained from the patient's medical records. Univariate analysis was used to analyze the potential factors associated with an unsuccessful bilateral SLN biopsy. <b>Results</b> The bilateral SLN detection rate of planar lymphoscintigraphy, single photon emission computed tomography/computed tomography, and gamma probe was 29.26, 41.46, and 26.82%, correspondingly. None of the 16 analyzed risk factors showed statistical significance for nonconclusive bilateral SLN biopsy. <b>Conclusion</b> Larger scale studies are needed to determine the exact risk factors for unsuccessful bilateral mapping of the lymphatic drainage after cervical application of the radiotracers. This will eventually lead to improvement in bilateral SLN detection in EC patients, so unilateral lymphadenectomy could be avoided.</p>","PeriodicalId":23742,"journal":{"name":"World Journal of Nuclear Medicine","volume":"22 4","pages":"261-266"},"PeriodicalIF":0.6000,"publicationDate":"2023-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10751129/pdf/","citationCount":"0","resultStr":"{\"title\":\"Predictors of Bilateral SLN Radiocolloid Detection in Endometrial Carcinoma.\",\"authors\":\"Anamarija Jankulovska, Sasho Stojcevski, Igor Aluloski, Mile Tanturovski, Nevena Manevska, Ana Daneva Markova, Sinisa Stojanoski\",\"doi\":\"10.1055/s-0043-1777693\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Introduction</b> Sentinel lymph node (SLN) mapping is an alternative method to conventional lymphadenectomy for nodal status assessment in patients with stage I/II endometrial carcinoma (EC). This study aimed to analyze the potential predictors of unsuccessful bilateral detection of SLN after the application of radiocolloid in EC. <b>Materials and Methods</b> A prospective, observational, cross-sectional study was performed on 41 patients with EC in preoperative stage I, who underwent SLN mapping after cervical application of 4mCi <sup>99m</sup> Tc-SENTI-SCINT. The demographic, clinical, and tumor-related data were obtained from the patient's medical records. Univariate analysis was used to analyze the potential factors associated with an unsuccessful bilateral SLN biopsy. <b>Results</b> The bilateral SLN detection rate of planar lymphoscintigraphy, single photon emission computed tomography/computed tomography, and gamma probe was 29.26, 41.46, and 26.82%, correspondingly. None of the 16 analyzed risk factors showed statistical significance for nonconclusive bilateral SLN biopsy. <b>Conclusion</b> Larger scale studies are needed to determine the exact risk factors for unsuccessful bilateral mapping of the lymphatic drainage after cervical application of the radiotracers. This will eventually lead to improvement in bilateral SLN detection in EC patients, so unilateral lymphadenectomy could be avoided.</p>\",\"PeriodicalId\":23742,\"journal\":{\"name\":\"World Journal of Nuclear Medicine\",\"volume\":\"22 4\",\"pages\":\"261-266\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2023-12-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10751129/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"World Journal of Nuclear Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1777693\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1777693","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Predictors of Bilateral SLN Radiocolloid Detection in Endometrial Carcinoma.
Introduction Sentinel lymph node (SLN) mapping is an alternative method to conventional lymphadenectomy for nodal status assessment in patients with stage I/II endometrial carcinoma (EC). This study aimed to analyze the potential predictors of unsuccessful bilateral detection of SLN after the application of radiocolloid in EC. Materials and Methods A prospective, observational, cross-sectional study was performed on 41 patients with EC in preoperative stage I, who underwent SLN mapping after cervical application of 4mCi 99m Tc-SENTI-SCINT. The demographic, clinical, and tumor-related data were obtained from the patient's medical records. Univariate analysis was used to analyze the potential factors associated with an unsuccessful bilateral SLN biopsy. Results The bilateral SLN detection rate of planar lymphoscintigraphy, single photon emission computed tomography/computed tomography, and gamma probe was 29.26, 41.46, and 26.82%, correspondingly. None of the 16 analyzed risk factors showed statistical significance for nonconclusive bilateral SLN biopsy. Conclusion Larger scale studies are needed to determine the exact risk factors for unsuccessful bilateral mapping of the lymphatic drainage after cervical application of the radiotracers. This will eventually lead to improvement in bilateral SLN detection in EC patients, so unilateral lymphadenectomy could be avoided.