胃肠吻合术中订书针的机械性能和组织损伤。

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2024-01-01 Epub Date: 2023-12-29 DOI:10.1177/09544119231216283
Xuan Dai, Junjie Zheng, Xiaoli Yu, Zhihua Liu, Lijuan Zheng, Zhihua Chen, Chengyong Wang
{"title":"胃肠吻合术中订书针的机械性能和组织损伤。","authors":"Xuan Dai, Junjie Zheng, Xiaoli Yu, Zhihua Liu, Lijuan Zheng, Zhihua Chen, Chengyong Wang","doi":"10.1177/09544119231216283","DOIUrl":null,"url":null,"abstract":"<p><p>Gastrointestinal surgery using a stapler is usually associated with tissue damage, anastomosis leakage, bleeding, and other complications, which is one of the effective methods for treating digestive tract cancer. The cutting properties of staples and the tissue damage occurring in the process of stapling porcine esophageal and gastric tissues have been evaluated and a new type of stapler has been designed. Since different structural and mechanical properties esophageal and gastric tissues layers, the puncturing force exhibits a fluctuating trend. Compressive stress caused by the bending of the staple legs can lead to the destruction of the vascular network inside the tissue, tissue deforms and tears. Finally, a staple with an internal incision arc (IIA) tip is designed, which meeting the performance requirements.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanical properties and tissue damage caused by staples in gastrointestinal anastomosis.\",\"authors\":\"Xuan Dai, Junjie Zheng, Xiaoli Yu, Zhihua Liu, Lijuan Zheng, Zhihua Chen, Chengyong Wang\",\"doi\":\"10.1177/09544119231216283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Gastrointestinal surgery using a stapler is usually associated with tissue damage, anastomosis leakage, bleeding, and other complications, which is one of the effective methods for treating digestive tract cancer. The cutting properties of staples and the tissue damage occurring in the process of stapling porcine esophageal and gastric tissues have been evaluated and a new type of stapler has been designed. Since different structural and mechanical properties esophageal and gastric tissues layers, the puncturing force exhibits a fluctuating trend. Compressive stress caused by the bending of the staple legs can lead to the destruction of the vascular network inside the tissue, tissue deforms and tears. Finally, a staple with an internal incision arc (IIA) tip is designed, which meeting the performance requirements.</p>\",\"PeriodicalId\":20666,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09544119231216283\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119231216283","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

使用订书机进行胃肠道手术通常会出现组织损伤、吻合口渗漏、出血和其他并发症,这是治疗消化道癌症的有效方法之一。我们对猪食管和胃组织的订书机切割性能和订书过程中出现的组织损伤进行了评估,并设计了一种新型订书机。由于食管和胃组织层的结构和机械性能不同,穿刺力呈现波动趋势。钉腿弯曲造成的压应力会导致组织内部的血管网遭到破坏,组织变形和撕裂。最后,我们设计了一种带有内切口弧形(IIA)尖端的缝合钉,它能满足性能要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mechanical properties and tissue damage caused by staples in gastrointestinal anastomosis.

Gastrointestinal surgery using a stapler is usually associated with tissue damage, anastomosis leakage, bleeding, and other complications, which is one of the effective methods for treating digestive tract cancer. The cutting properties of staples and the tissue damage occurring in the process of stapling porcine esophageal and gastric tissues have been evaluated and a new type of stapler has been designed. Since different structural and mechanical properties esophageal and gastric tissues layers, the puncturing force exhibits a fluctuating trend. Compressive stress caused by the bending of the staple legs can lead to the destruction of the vascular network inside the tissue, tissue deforms and tears. Finally, a staple with an internal incision arc (IIA) tip is designed, which meeting the performance requirements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
期刊最新文献
Artificial intelligence and health-related data: The patient’s best interest and data ownership dilemma Explant analysis of a chromium nitride coated metal-on-metal total wrist replacement: A case study Effects of self-etch adhesive agitation with diode laser on dentin bond strength Computational analysis of the biomechanical stability of internal fixation of the lateral tibial plateau fracture: A mechanical stability study. The effect of structural changes on the low strain rate behaviour of the intervertebral disc.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1