冷冻球囊消融引起的假迷走神经反应

Q3 Medicine Journal of Innovations in Cardiac Rhythm Management Pub Date : 2023-12-15 eCollection Date: 2023-12-01 DOI:10.19102/icrm.2023.14123
Daniel Sohinki, Vinay Mehta, Jeffrey Ardell, Stavros Stavrakis, Sunny S Po, Ali Yousif
{"title":"冷冻球囊消融引起的假迷走神经反应","authors":"Daniel Sohinki, Vinay Mehta, Jeffrey Ardell, Stavros Stavrakis, Sunny S Po, Ali Yousif","doi":"10.19102/icrm.2023.14123","DOIUrl":null,"url":null,"abstract":"<p><p>Pulmonary vein isolation via cryoballoon (CB) ablation is the cornerstone ablation strategy for the treatment of atrial fibrillation (AF). Acute intraprocedural hypotensive and/or bradycardic responses have been reported in patients undergoing CB ablation for AF. However, it remains unclear as to whether these are due to a true vagal response (VR), which can be used to predict long-term outcomes of CB ablation. We analyzed 139 freezes across 17 patients who received CB ablation for paroxysmal AF, measuring vital signs and freeze characteristics. Only one freeze was associated with both hypotension and bradycardia, constituting a true VR. Several freezes were associated with hypotension only that did not respond to atropine administration, suggesting that these responses are not associated with a VR. Hypotensive responses were significantly associated with ice bubble bursts during CB deflation. Unlike the true VR reported in patients undergoing conscious sedation, the presence of acute hypotension shortly after CB deflation cannot be used as a predictor for long-term ablation outcomes.</p>","PeriodicalId":36299,"journal":{"name":"Journal of Innovations in Cardiac Rhythm Management","volume":"14 12","pages":"5690-5696"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10752428/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pseudo-vagal Responses Elicited by Cryoballoon Ablation.\",\"authors\":\"Daniel Sohinki, Vinay Mehta, Jeffrey Ardell, Stavros Stavrakis, Sunny S Po, Ali Yousif\",\"doi\":\"10.19102/icrm.2023.14123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pulmonary vein isolation via cryoballoon (CB) ablation is the cornerstone ablation strategy for the treatment of atrial fibrillation (AF). Acute intraprocedural hypotensive and/or bradycardic responses have been reported in patients undergoing CB ablation for AF. However, it remains unclear as to whether these are due to a true vagal response (VR), which can be used to predict long-term outcomes of CB ablation. We analyzed 139 freezes across 17 patients who received CB ablation for paroxysmal AF, measuring vital signs and freeze characteristics. Only one freeze was associated with both hypotension and bradycardia, constituting a true VR. Several freezes were associated with hypotension only that did not respond to atropine administration, suggesting that these responses are not associated with a VR. Hypotensive responses were significantly associated with ice bubble bursts during CB deflation. Unlike the true VR reported in patients undergoing conscious sedation, the presence of acute hypotension shortly after CB deflation cannot be used as a predictor for long-term ablation outcomes.</p>\",\"PeriodicalId\":36299,\"journal\":{\"name\":\"Journal of Innovations in Cardiac Rhythm Management\",\"volume\":\"14 12\",\"pages\":\"5690-5696\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10752428/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Innovations in Cardiac Rhythm Management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19102/icrm.2023.14123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Cardiac Rhythm Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19102/icrm.2023.14123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/12/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

通过冷冻球囊(CB)消融术进行肺静脉隔离是治疗心房颤动(房颤)的基础消融策略。据报道,接受 CB 消融术治疗房颤的患者在术中会出现急性低血压和/或心动过缓反应。然而,目前仍不清楚这些反应是否是由真正的迷走神经反应(VR)引起的,而迷走神经反应可用于预测 CB 消融术的长期疗效。我们分析了 17 位接受 CB 消融术治疗阵发性房颤的患者的 139 次冻结,测量了生命体征和冻结特征。只有一次冻结同时伴有低血压和心动过缓,构成了真正的 VR。有几例冻结仅伴有低血压,但对阿托品给药没有反应,这表明这些反应与 VR 无关。在 CB 放气过程中,低血压反应与冰泡破裂密切相关。与接受有意识镇静的患者所报告的真正 VR 不同,CB 放气后不久出现的急性低血压不能作为长期消融结果的预测指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Pseudo-vagal Responses Elicited by Cryoballoon Ablation.

Pulmonary vein isolation via cryoballoon (CB) ablation is the cornerstone ablation strategy for the treatment of atrial fibrillation (AF). Acute intraprocedural hypotensive and/or bradycardic responses have been reported in patients undergoing CB ablation for AF. However, it remains unclear as to whether these are due to a true vagal response (VR), which can be used to predict long-term outcomes of CB ablation. We analyzed 139 freezes across 17 patients who received CB ablation for paroxysmal AF, measuring vital signs and freeze characteristics. Only one freeze was associated with both hypotension and bradycardia, constituting a true VR. Several freezes were associated with hypotension only that did not respond to atropine administration, suggesting that these responses are not associated with a VR. Hypotensive responses were significantly associated with ice bubble bursts during CB deflation. Unlike the true VR reported in patients undergoing conscious sedation, the presence of acute hypotension shortly after CB deflation cannot be used as a predictor for long-term ablation outcomes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Innovations in Cardiac Rhythm Management
Journal of Innovations in Cardiac Rhythm Management Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.50
自引率
0.00%
发文量
70
期刊最新文献
2024 Literature Review of Postoperative Atrial Fibrillation: A Surgeon's Perspective. A Year in Review: Atrial Fibrillation 2024. Comparison of Electrocardiogram Characteristics of Two Commercially Available Implantable Loop Monitors: Impact of These Characteristics in the Correct Adjudication of Recorded Events and Minimized Undersensing and Oversensing of Events. Conduction System Pacing: Where Are We in 2025? Late Onset of Left Atrial Appendage Thrombus Under Oral Anticoagulation in a Patient with a History of Left Atrial Appendage Isolation Using Cryoballoon.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1