新型绿色高通量微孔分光光度法:通过微量生成 N-乙烯萘胺萘醌衍生物控制选择性羟色胺再摄取抑制剂药物制剂的质量

IF 1.7 4区 化学 Q3 CHEMISTRY, ANALYTICAL Current Analytical Chemistry Pub Date : 2023-12-29 DOI:10.2174/0115734110281768231226115944
Reem M. Abuhejail, Nourah Z. Alzoman, Ibrahim A. Darwish
{"title":"新型绿色高通量微孔分光光度法:通过微量生成 N-乙烯萘胺萘醌衍生物控制选择性羟色胺再摄取抑制剂药物制剂的质量","authors":"Reem M. Abuhejail, Nourah Z. Alzoman, Ibrahim A. Darwish","doi":"10.2174/0115734110281768231226115944","DOIUrl":null,"url":null,"abstract":"Background: Selective serotonin reuptake inhibitors (SSRIs) are mostly prescribed for the treatment of depression. This study describes the microscale in-microwell formation of blue-colored N-vinylamino-naphthoquinone derivatives of SSRIs upon their reaction with 2,3-dichloro-1,4- naphthoquinone (DCNQ) and acetaldehyde. The reaction was subsequently utilized as a basis for the development of a new simple and sensitive microwell spectrophotometric method (MW-SPM) for the quality control of pharmaceutical formulations of four SSRIs. These SSRIs are fluoxetine (FLU), sertraline (SER), paroxetine (PAR), and reboxetine (REB). Methods: The MW-SPM procedure was performed in 96-microwell transparent plates, and the microplate reader was employed to measure the absorbances of the reaction products at their peak absorbance wavelength of 580 nm. The best conditions for the method were determined. Results: The relations showed good linearity (correlation coefficients were ≥0.9992) in the concentration range of 5 – 600 µg/mL. The limits of detection ranged from 5.20 to 15.58 µg/mL. The precision was deemed acceptable since all cases' relative standard deviation (RSD) values remained below 2.21%. Recovery experiments were conducted to confirm the accuracy of the method, yielding recovery values of at least 97.8%. The MW-SPM method was effectively utilized to analyze SSRIs in both their bulk and pharmaceutical dosage forms, exhibiting acceptable accuracy and precision. The recovery values ranged from 99.4% to 101.0% (with a margin of error of ± 0.5% to 1.6%). The results were comparable with those of the pre-validated reported methods. Four different metric tools evaluated the greenness of the proposed method, and the results proved that the method fulfills the requirements of green analytical approaches. Furthermore, the ability to handle numerous microvolume samples simultaneously in the described method provides it with a high-throughput characteristic. Conclusion: The proposed MW-SPM represents a valuable tool for an efficient analysis of SSRIs in pharmaceutical quality control units.","PeriodicalId":10742,"journal":{"name":"Current Analytical Chemistry","volume":"4 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Green and High-throughput Microwell Spectrophotometric Method for Quality Control of Pharmaceutical Formulations of Selective Serotonin Reuptake Inhibitors via Microscale Formation of their N-Vinylaminonaphthoquinone Derivatives\",\"authors\":\"Reem M. Abuhejail, Nourah Z. Alzoman, Ibrahim A. Darwish\",\"doi\":\"10.2174/0115734110281768231226115944\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Selective serotonin reuptake inhibitors (SSRIs) are mostly prescribed for the treatment of depression. This study describes the microscale in-microwell formation of blue-colored N-vinylamino-naphthoquinone derivatives of SSRIs upon their reaction with 2,3-dichloro-1,4- naphthoquinone (DCNQ) and acetaldehyde. The reaction was subsequently utilized as a basis for the development of a new simple and sensitive microwell spectrophotometric method (MW-SPM) for the quality control of pharmaceutical formulations of four SSRIs. These SSRIs are fluoxetine (FLU), sertraline (SER), paroxetine (PAR), and reboxetine (REB). Methods: The MW-SPM procedure was performed in 96-microwell transparent plates, and the microplate reader was employed to measure the absorbances of the reaction products at their peak absorbance wavelength of 580 nm. The best conditions for the method were determined. Results: The relations showed good linearity (correlation coefficients were ≥0.9992) in the concentration range of 5 – 600 µg/mL. The limits of detection ranged from 5.20 to 15.58 µg/mL. The precision was deemed acceptable since all cases' relative standard deviation (RSD) values remained below 2.21%. Recovery experiments were conducted to confirm the accuracy of the method, yielding recovery values of at least 97.8%. The MW-SPM method was effectively utilized to analyze SSRIs in both their bulk and pharmaceutical dosage forms, exhibiting acceptable accuracy and precision. The recovery values ranged from 99.4% to 101.0% (with a margin of error of ± 0.5% to 1.6%). The results were comparable with those of the pre-validated reported methods. Four different metric tools evaluated the greenness of the proposed method, and the results proved that the method fulfills the requirements of green analytical approaches. Furthermore, the ability to handle numerous microvolume samples simultaneously in the described method provides it with a high-throughput characteristic. Conclusion: The proposed MW-SPM represents a valuable tool for an efficient analysis of SSRIs in pharmaceutical quality control units.\",\"PeriodicalId\":10742,\"journal\":{\"name\":\"Current Analytical Chemistry\",\"volume\":\"4 1\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2023-12-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.2174/0115734110281768231226115944\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.2174/0115734110281768231226115944","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:选择性血清素再摄取抑制剂(SSRIs)主要用于治疗抑郁症。本研究描述了 SSRIs 与 2,3-二氯-1,4-萘醌(DCNQ)和乙醛反应后在微孔中形成的蓝色 N-乙烯萘醌衍生物。随后,以该反应为基础,开发了一种简单灵敏的微孔分光光度法(MW-SPM),用于四种 SSRIs 药物制剂的质量控制。这些 SSRIs 包括氟西汀 (FLU)、舍曲林 (SER)、帕罗西汀 (PAR) 和瑞波西汀 (REB)。研究方法在 96 微孔透明板中进行 MW-SPM 程序,使用微孔板阅读器测量反应产物在 580 纳米吸光峰波长处的吸光度。确定了该方法的最佳条件。结果表明在 5 - 600 µg/mL 浓度范围内,线性关系良好(相关系数≥0.9992)。检测限为 5.20 至 15.58 微克/毫升。由于所有情况下的相对标准偏差 (RSD) 值都低于 2.21%,因此精密度可以接受。为确认方法的准确性,进行了回收实验,回收率至少为 97.8%。MW-SPM 方法被有效地用于分析散装和药物剂型中的 SSRIs,其准确度和精密度均可接受。回收率为 99.4% 至 101.0%(误差范围为 ± 0.5% 至 1.6%)。结果与已报告的预验证方法相当。四种不同的度量工具对拟议方法的绿色性进行了评估,结果证明该方法符合绿色分析方法的要求。此外,该方法能同时处理大量微量样品,因此具有高通量的特点。结论所提出的 MW-SPM 是药品质量控制部门高效分析 SSRIs 的重要工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New Green and High-throughput Microwell Spectrophotometric Method for Quality Control of Pharmaceutical Formulations of Selective Serotonin Reuptake Inhibitors via Microscale Formation of their N-Vinylaminonaphthoquinone Derivatives
Background: Selective serotonin reuptake inhibitors (SSRIs) are mostly prescribed for the treatment of depression. This study describes the microscale in-microwell formation of blue-colored N-vinylamino-naphthoquinone derivatives of SSRIs upon their reaction with 2,3-dichloro-1,4- naphthoquinone (DCNQ) and acetaldehyde. The reaction was subsequently utilized as a basis for the development of a new simple and sensitive microwell spectrophotometric method (MW-SPM) for the quality control of pharmaceutical formulations of four SSRIs. These SSRIs are fluoxetine (FLU), sertraline (SER), paroxetine (PAR), and reboxetine (REB). Methods: The MW-SPM procedure was performed in 96-microwell transparent plates, and the microplate reader was employed to measure the absorbances of the reaction products at their peak absorbance wavelength of 580 nm. The best conditions for the method were determined. Results: The relations showed good linearity (correlation coefficients were ≥0.9992) in the concentration range of 5 – 600 µg/mL. The limits of detection ranged from 5.20 to 15.58 µg/mL. The precision was deemed acceptable since all cases' relative standard deviation (RSD) values remained below 2.21%. Recovery experiments were conducted to confirm the accuracy of the method, yielding recovery values of at least 97.8%. The MW-SPM method was effectively utilized to analyze SSRIs in both their bulk and pharmaceutical dosage forms, exhibiting acceptable accuracy and precision. The recovery values ranged from 99.4% to 101.0% (with a margin of error of ± 0.5% to 1.6%). The results were comparable with those of the pre-validated reported methods. Four different metric tools evaluated the greenness of the proposed method, and the results proved that the method fulfills the requirements of green analytical approaches. Furthermore, the ability to handle numerous microvolume samples simultaneously in the described method provides it with a high-throughput characteristic. Conclusion: The proposed MW-SPM represents a valuable tool for an efficient analysis of SSRIs in pharmaceutical quality control units.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Analytical Chemistry
Current Analytical Chemistry 化学-分析化学
CiteScore
4.10
自引率
0.00%
发文量
90
审稿时长
9 months
期刊介绍: Current Analytical Chemistry publishes full-length/mini reviews and original research articles on the most recent advances in analytical chemistry. All aspects of the field are represented, including analytical methodology, techniques, and instrumentation in both fundamental and applied research topics of interest to the broad readership of the journal. Current Analytical Chemistry strives to serve as an authoritative source of information in analytical chemistry and in related applications such as biochemical analysis, pharmaceutical research, quantitative biological imaging, novel sensors, and nanotechnology.
期刊最新文献
Purification and Kinetics of Chlorogenic Acid from Eucommia ulmoides Oliver Leaves by Macroporous Resins Combined with First-Principles Calculation Research Progress in Starch-based Dye Adsorbents Electrochemical Behavior of an Anti-cancer Drug Erlotinib at Screen-Printed Electrode and its Analytical Application Polygonum hydropiper Leaves have More Medicinal Value than Stems: Based on Chemical Composition and Antioxidant Activity In silico Investigation and Molecular Docking Studies of Pyrazole Incorporated Thiadiazole Derivatives for Antimicrobial Activities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1