1 型糖尿病成人患者的连续血糖监测警报:用户特征以及低血糖和高血糖警报阈值对血糖控制的影响。

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2024-05-01 Epub Date: 2024-03-08 DOI:10.1089/dia.2023.0460
Tomás González-Vidal, Diego Rivas-Otero, Pablo Agüeria-Cabal, Guillermo Ramos-Ruiz, Elías Delgado, Edelmiro Menéndez-Torre
{"title":"1 型糖尿病成人患者的连续血糖监测警报:用户特征以及低血糖和高血糖警报阈值对血糖控制的影响。","authors":"Tomás González-Vidal, Diego Rivas-Otero, Pablo Agüeria-Cabal, Guillermo Ramos-Ruiz, Elías Delgado, Edelmiro Menéndez-Torre","doi":"10.1089/dia.2023.0460","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> Few studies have evaluated the implications of the alarm thresholds of continuous glucose monitoring (CGM) systems for individuals with diabetes. The present study aimed to investigate the influence of hypoglycemia and hyperglycemia alarm thresholds on glycemic control in adults with type 1 diabetes (T1DM) and the characteristics of patients who use these alarms more frequently. <b><i>Methods:</i></b> This observational cross-sectional study included 873 users of the <i>FreeStyle Libre 2</i> system (501 men, median age 48 years, range 18-90 years) with T1DM from a single center. We investigated the role of demographic and metabolic factors on the use of alarms and the impact of hypoglycemia and hyperglycemia alarms and their thresholds on glycemic control. <b><i>Results:</i></b> Alarm users were older than nonusers (median age 49 vs. 43 years, respectively; <i>P</i> < 0.001). The hypoglycemia alarms were set by 76.1% of women and by 69.1% of men (<i>P</i> = 0.022). The hypoglycemia alarms reduced hypoglycemia features and glucose variability, although at the expense of shorter time in range. The higher the hypoglycemia alarm threshold, the greater these effects. The hyperglycemia alarms were effective in reducing hyperglycemia and lowering the glucose management indicator, although at the expense of a greater tendency to hypoglycemia. The lower the hyperglycemia alarm threshold, the greater these effects. <b><i>Conclusions:</i></b> CGM alarms contribute to better glycemic control. However, hypoglycemia and hyperglycemia alarms have advantages and disadvantages. Adults with T1DM should explore, under medical supervision, which alarm thresholds will best help them achieve their individual glycemic goals.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic Control.\",\"authors\":\"Tomás González-Vidal, Diego Rivas-Otero, Pablo Agüeria-Cabal, Guillermo Ramos-Ruiz, Elías Delgado, Edelmiro Menéndez-Torre\",\"doi\":\"10.1089/dia.2023.0460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background:</i></b> Few studies have evaluated the implications of the alarm thresholds of continuous glucose monitoring (CGM) systems for individuals with diabetes. The present study aimed to investigate the influence of hypoglycemia and hyperglycemia alarm thresholds on glycemic control in adults with type 1 diabetes (T1DM) and the characteristics of patients who use these alarms more frequently. <b><i>Methods:</i></b> This observational cross-sectional study included 873 users of the <i>FreeStyle Libre 2</i> system (501 men, median age 48 years, range 18-90 years) with T1DM from a single center. We investigated the role of demographic and metabolic factors on the use of alarms and the impact of hypoglycemia and hyperglycemia alarms and their thresholds on glycemic control. <b><i>Results:</i></b> Alarm users were older than nonusers (median age 49 vs. 43 years, respectively; <i>P</i> < 0.001). The hypoglycemia alarms were set by 76.1% of women and by 69.1% of men (<i>P</i> = 0.022). The hypoglycemia alarms reduced hypoglycemia features and glucose variability, although at the expense of shorter time in range. The higher the hypoglycemia alarm threshold, the greater these effects. The hyperglycemia alarms were effective in reducing hyperglycemia and lowering the glucose management indicator, although at the expense of a greater tendency to hypoglycemia. The lower the hyperglycemia alarm threshold, the greater these effects. <b><i>Conclusions:</i></b> CGM alarms contribute to better glycemic control. However, hypoglycemia and hyperglycemia alarms have advantages and disadvantages. Adults with T1DM should explore, under medical supervision, which alarm thresholds will best help them achieve their individual glycemic goals.</p>\",\"PeriodicalId\":11159,\"journal\":{\"name\":\"Diabetes technology & therapeutics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.7000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diabetes technology & therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/dia.2023.0460\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2023.0460","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

摘要

背景:很少有研究评估连续血糖监测系统报警阈值对糖尿病患者的影响。本研究旨在调查低血糖和高血糖报警阈值对 1 型糖尿病成人患者血糖控制的影响,以及频繁使用这些报警的患者的特征:这项观察性横断面研究纳入了来自一个中心的 873 名 FreeStyle Libre 2 系统用户(501 名男性,中位年龄 48 岁,范围 18-90 岁)1 型糖尿病患者。我们调查了人口统计学和代谢因素对警报器使用的影响,以及低血糖和高血糖警报器及其阈值对血糖控制的影响:结果:警报器使用者的年龄大于非使用者(中位年龄分别为 49 岁和 43 岁;p 结论:连续血糖监测警报器有助于控制血糖:连续血糖监测报警器有助于更好地控制血糖。然而,低血糖和高血糖报警器各有利弊。1 型糖尿病患者应在医生的指导下,探索哪种报警阈值最能帮助他们实现各自的血糖目标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Continuous Glucose Monitoring Alarms in Adults with Type 1 Diabetes: User Characteristics and the Impact of Hypoglycemia and Hyperglycemia Alarm Thresholds on Glycemic Control.

Background: Few studies have evaluated the implications of the alarm thresholds of continuous glucose monitoring (CGM) systems for individuals with diabetes. The present study aimed to investigate the influence of hypoglycemia and hyperglycemia alarm thresholds on glycemic control in adults with type 1 diabetes (T1DM) and the characteristics of patients who use these alarms more frequently. Methods: This observational cross-sectional study included 873 users of the FreeStyle Libre 2 system (501 men, median age 48 years, range 18-90 years) with T1DM from a single center. We investigated the role of demographic and metabolic factors on the use of alarms and the impact of hypoglycemia and hyperglycemia alarms and their thresholds on glycemic control. Results: Alarm users were older than nonusers (median age 49 vs. 43 years, respectively; P < 0.001). The hypoglycemia alarms were set by 76.1% of women and by 69.1% of men (P = 0.022). The hypoglycemia alarms reduced hypoglycemia features and glucose variability, although at the expense of shorter time in range. The higher the hypoglycemia alarm threshold, the greater these effects. The hyperglycemia alarms were effective in reducing hyperglycemia and lowering the glucose management indicator, although at the expense of a greater tendency to hypoglycemia. The lower the hyperglycemia alarm threshold, the greater these effects. Conclusions: CGM alarms contribute to better glycemic control. However, hypoglycemia and hyperglycemia alarms have advantages and disadvantages. Adults with T1DM should explore, under medical supervision, which alarm thresholds will best help them achieve their individual glycemic goals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
Safety of Options to "Boost" (Enhancing Insulin Infusion Rates) and "Ease-Off" (Reducing Insulin Infusion Rates) in CamAPS FX Hybrid Closed-Loop System: A Real-World Analysis. Clinical Utility of Serum C-peptide Concentration for Hospitalized Patients with Hyperglycemia. An Automated Insulin Delivery System with Automatic Meal Bolus Based on a Hand-Gesturing Algorithm. Noninvasive Real-Time Glucose Monitoring Is in the Near Future. Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1