{"title":"改进蛋白质检测方法,更准确地评估医疗器械清洁度。","authors":"Terra A Kremer, Allan Kimble, Christopher Ratanski","doi":"10.2345/0899-8205-57.4.122","DOIUrl":null,"url":null,"abstract":"<p><p>Protein assays commonly used to evaluate reusable device cleanliness do not always accurately measure the low concentrations of protein that are expected on reusable medical devices after processing. Methods often are adapted to provide an estimation of protein concentration; however, sensitivity issues in the portion of standard curves at the acceptance criteria of 6.4 μg/cm<sup>2</sup> protein have been reported. Using analytical validation criteria, method improvements for the micro-bicinchoninic acid assay for protein residuals are demonstrated by incorporating a standard addition method, increasing the well volume, and changing the working reagent ratio. These improvements increased method sensitivity and accuracy in the reliable detection of protein levels for device cleaning validations.</p>","PeriodicalId":35656,"journal":{"name":"Biomedical Instrumentation and Technology","volume":"57 4","pages":"122-128"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10764063/pdf/","citationCount":"0","resultStr":"{\"title\":\"Improving Protein Assay Methods to More Accurately Assess Medical Device Cleanliness.\",\"authors\":\"Terra A Kremer, Allan Kimble, Christopher Ratanski\",\"doi\":\"10.2345/0899-8205-57.4.122\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Protein assays commonly used to evaluate reusable device cleanliness do not always accurately measure the low concentrations of protein that are expected on reusable medical devices after processing. Methods often are adapted to provide an estimation of protein concentration; however, sensitivity issues in the portion of standard curves at the acceptance criteria of 6.4 μg/cm<sup>2</sup> protein have been reported. Using analytical validation criteria, method improvements for the micro-bicinchoninic acid assay for protein residuals are demonstrated by incorporating a standard addition method, increasing the well volume, and changing the working reagent ratio. These improvements increased method sensitivity and accuracy in the reliable detection of protein levels for device cleaning validations.</p>\",\"PeriodicalId\":35656,\"journal\":{\"name\":\"Biomedical Instrumentation and Technology\",\"volume\":\"57 4\",\"pages\":\"122-128\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10764063/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Instrumentation and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2345/0899-8205-57.4.122\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Instrumentation and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2345/0899-8205-57.4.122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
Improving Protein Assay Methods to More Accurately Assess Medical Device Cleanliness.
Protein assays commonly used to evaluate reusable device cleanliness do not always accurately measure the low concentrations of protein that are expected on reusable medical devices after processing. Methods often are adapted to provide an estimation of protein concentration; however, sensitivity issues in the portion of standard curves at the acceptance criteria of 6.4 μg/cm2 protein have been reported. Using analytical validation criteria, method improvements for the micro-bicinchoninic acid assay for protein residuals are demonstrated by incorporating a standard addition method, increasing the well volume, and changing the working reagent ratio. These improvements increased method sensitivity and accuracy in the reliable detection of protein levels for device cleaning validations.
期刊介绍:
AAMI publishes Biomedical Instrumentation & Technology (BI&T) a bi-monthly peer-reviewed journal dedicated to the developers, managers, and users of medical instrumentation and technology.