使用无创抽吸装置评估乳房皮肤和组织硬度以及临床预测因素的影响。

IF 2.3 4区 医学 Q1 ANATOMY & MORPHOLOGY Clinical Anatomy Pub Date : 2024-01-04 DOI:10.1002/ca.24134
Martha Duraes, Noemie Briot, Nathanael Connesson, Gregory Chagnon, Yohan Payan, Claire Duflos, Gauthier Rathat, Guillaume Captier, Gerard Subsol, Christian Herlin
{"title":"使用无创抽吸装置评估乳房皮肤和组织硬度以及临床预测因素的影响。","authors":"Martha Duraes,&nbsp;Noemie Briot,&nbsp;Nathanael Connesson,&nbsp;Gregory Chagnon,&nbsp;Yohan Payan,&nbsp;Claire Duflos,&nbsp;Gauthier Rathat,&nbsp;Guillaume Captier,&nbsp;Gerard Subsol,&nbsp;Christian Herlin","doi":"10.1002/ca.24134","DOIUrl":null,"url":null,"abstract":"<p>A personalized 3D breast model could present a real benefit for preoperative discussion with patients, surgical planning, and guidance. Breast tissue biomechanical properties have been poorly studied in vivo, although they are important for breast deformation simulation. The main objective of our study was to determine breast skin thickness and breast skin and adipose/fibroglandular tissue stiffness. The secondary objective was to assess clinical predictors of elasticity and thickness: age, smoking status, body mass index, contraception, pregnancies, breastfeeding, menopausal status, history of radiotherapy or breast surgery. Participants were included at the Montpellier University Breast Surgery Department from March to May 2022. Breast skin thickness was measured by ultrasonography, breast skin and adipose/fibroglandular tissue stiffnesses were determined with a VLASTIC non-invasive aspiration device at three different sites (breast segments I–III). Multivariable linear models were used to assess clinical predictors of elasticity and thickness. In this cohort of 196 women, the mean breast skin and adipose/fibroglandular tissue stiffness values were 39 and 3 kPa, respectively. The mean breast skin thickness was 1.83 mm. Only menopausal status was significantly correlated with breast skin thickness and adipose/fibroglandular tissue stiffness. The next step will be to implement these stiffness and thickness values in a biomechanical breast model and to evaluate its capacity to predict breast tissue deformations.</p>","PeriodicalId":50687,"journal":{"name":"Clinical Anatomy","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ca.24134","citationCount":"0","resultStr":"{\"title\":\"Evaluation of breast skin and tissue stiffness using a non-invasive aspiration device and impact of clinical predictors\",\"authors\":\"Martha Duraes,&nbsp;Noemie Briot,&nbsp;Nathanael Connesson,&nbsp;Gregory Chagnon,&nbsp;Yohan Payan,&nbsp;Claire Duflos,&nbsp;Gauthier Rathat,&nbsp;Guillaume Captier,&nbsp;Gerard Subsol,&nbsp;Christian Herlin\",\"doi\":\"10.1002/ca.24134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A personalized 3D breast model could present a real benefit for preoperative discussion with patients, surgical planning, and guidance. Breast tissue biomechanical properties have been poorly studied in vivo, although they are important for breast deformation simulation. The main objective of our study was to determine breast skin thickness and breast skin and adipose/fibroglandular tissue stiffness. The secondary objective was to assess clinical predictors of elasticity and thickness: age, smoking status, body mass index, contraception, pregnancies, breastfeeding, menopausal status, history of radiotherapy or breast surgery. Participants were included at the Montpellier University Breast Surgery Department from March to May 2022. Breast skin thickness was measured by ultrasonography, breast skin and adipose/fibroglandular tissue stiffnesses were determined with a VLASTIC non-invasive aspiration device at three different sites (breast segments I–III). Multivariable linear models were used to assess clinical predictors of elasticity and thickness. In this cohort of 196 women, the mean breast skin and adipose/fibroglandular tissue stiffness values were 39 and 3 kPa, respectively. The mean breast skin thickness was 1.83 mm. Only menopausal status was significantly correlated with breast skin thickness and adipose/fibroglandular tissue stiffness. The next step will be to implement these stiffness and thickness values in a biomechanical breast model and to evaluate its capacity to predict breast tissue deformations.</p>\",\"PeriodicalId\":50687,\"journal\":{\"name\":\"Clinical Anatomy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ca.24134\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Anatomy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ca.24134\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ANATOMY & MORPHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Anatomy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ca.24134","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

个性化三维乳房模型可为患者术前讨论、手术规划和指导带来真正的好处。虽然乳房组织的生物力学特性对乳房变形模拟很重要,但对其进行的体内研究却很少。我们研究的主要目的是确定乳房皮肤厚度以及乳房皮肤和脂肪/纤维腺组织的硬度。次要目标是评估弹性和厚度的临床预测因素:年龄、吸烟状况、体重指数、避孕、怀孕、哺乳、绝经状况、放疗或乳房手术史。参与者于 2022 年 3 月至 5 月在蒙彼利埃大学乳腺外科就诊。乳房皮肤厚度通过超声波检查测量,乳房皮肤和脂肪/纤维腺组织硬度通过VLASTIC无创抽吸装置在三个不同部位(乳房I-III段)测定。采用多变量线性模型评估弹性和厚度的临床预测因素。在这组 196 名女性中,乳房皮肤和脂肪/纤维腺组织的平均硬度值分别为 39 千帕和 3 千帕。平均乳房皮肤厚度为 1.83 毫米。只有绝经状态与乳房皮肤厚度和脂肪/纤维腺组织硬度有明显的相关性。下一步将在乳房生物力学模型中应用这些硬度和厚度值,并评估其预测乳房组织变形的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of breast skin and tissue stiffness using a non-invasive aspiration device and impact of clinical predictors

A personalized 3D breast model could present a real benefit for preoperative discussion with patients, surgical planning, and guidance. Breast tissue biomechanical properties have been poorly studied in vivo, although they are important for breast deformation simulation. The main objective of our study was to determine breast skin thickness and breast skin and adipose/fibroglandular tissue stiffness. The secondary objective was to assess clinical predictors of elasticity and thickness: age, smoking status, body mass index, contraception, pregnancies, breastfeeding, menopausal status, history of radiotherapy or breast surgery. Participants were included at the Montpellier University Breast Surgery Department from March to May 2022. Breast skin thickness was measured by ultrasonography, breast skin and adipose/fibroglandular tissue stiffnesses were determined with a VLASTIC non-invasive aspiration device at three different sites (breast segments I–III). Multivariable linear models were used to assess clinical predictors of elasticity and thickness. In this cohort of 196 women, the mean breast skin and adipose/fibroglandular tissue stiffness values were 39 and 3 kPa, respectively. The mean breast skin thickness was 1.83 mm. Only menopausal status was significantly correlated with breast skin thickness and adipose/fibroglandular tissue stiffness. The next step will be to implement these stiffness and thickness values in a biomechanical breast model and to evaluate its capacity to predict breast tissue deformations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Anatomy
Clinical Anatomy 医学-解剖学与形态学
CiteScore
5.50
自引率
12.50%
发文量
154
审稿时长
3 months
期刊介绍: Clinical Anatomy is the Official Journal of the American Association of Clinical Anatomists and the British Association of Clinical Anatomists. The goal of Clinical Anatomy is to provide a medium for the exchange of current information between anatomists and clinicians. This journal embraces anatomy in all its aspects as applied to medical practice. Furthermore, the journal assists physicians and other health care providers in keeping abreast of new methodologies for patient management and informs educators of new developments in clinical anatomy and teaching techniques. Clinical Anatomy publishes original and review articles of scientific, clinical, and educational interest. Papers covering the application of anatomic principles to the solution of clinical problems and/or the application of clinical observations to expand anatomic knowledge are welcomed.
期刊最新文献
3D segmentation and quantitative analysis of age-related changes in the Hoffa fat pad using MRI. Infectious meningitis. Why are the leptomeninges preferentially involved? Electron microscopic insights. Comparison of ultrasound assisted and intraoperative diameter measurement in acute appendicitis. Issue Information Enhancing medical anatomy education with the integration of virtual reality into traditional lab settings.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1