{"title":"基于有限差分时域电磁回击模型的 10 千伏配电线路雷击过电压评估","authors":"Pan Duan,&nbsp;Lianfang Zhang,&nbsp;Xiaogang Huang,&nbsp;Jian Sun,&nbsp;Yue Qi,&nbsp;Qing Yang","doi":"10.1049/hve2.12392","DOIUrl":null,"url":null,"abstract":"<p>Accurate simulation of lightning-induced overvoltage for overhead distribution lines is helpful to prevent lightning trip accidents. An electromagnetic return-stroke model was used to represent lightning and then a 3D finite-difference time-domain (FDTD) method was adopted to simulate the lightning-induced overvoltage on a distribution line without a field-line coupling model. How lightning-induced overvoltage behave for different ground conductivity and varying distance between the distribution line and the lightning channel was analysed. The results showed that the overvoltage waveforms at the centre point of the line corresponding to lightning strikes on the lossy ground and an ideal ground (<i>σ</i> = ∞) were similar; however, the peak amplitudes of the waveform were affected by soil conductivity at a close distance. The relationship between magnitude of the overvoltage and distance can be described by a second-order exponential decay equation. Finally, the overvoltage calculated using the proposed model was compared with those obtained based on Agrawal's model and measurements made using the newly developed intelligent insulator on site. From these comparisons, it could be concluded that the FDTD method with the electromagnetic return-stroke model produces reasonably accurate results of the attenuated oscillation waveform, which can better reproduce the overvoltage on operational distribution lines.</p>","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2024-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12392","citationCount":"0","resultStr":"{\"title\":\"Evaluation of lightning-induced overvoltage on a 10 kV distribution line based on electromagnetic return-stroke model using finite-difference time-domain\",\"authors\":\"Pan Duan,&nbsp;Lianfang Zhang,&nbsp;Xiaogang Huang,&nbsp;Jian Sun,&nbsp;Yue Qi,&nbsp;Qing Yang\",\"doi\":\"10.1049/hve2.12392\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Accurate simulation of lightning-induced overvoltage for overhead distribution lines is helpful to prevent lightning trip accidents. An electromagnetic return-stroke model was used to represent lightning and then a 3D finite-difference time-domain (FDTD) method was adopted to simulate the lightning-induced overvoltage on a distribution line without a field-line coupling model. How lightning-induced overvoltage behave for different ground conductivity and varying distance between the distribution line and the lightning channel was analysed. The results showed that the overvoltage waveforms at the centre point of the line corresponding to lightning strikes on the lossy ground and an ideal ground (<i>σ</i> = ∞) were similar; however, the peak amplitudes of the waveform were affected by soil conductivity at a close distance. The relationship between magnitude of the overvoltage and distance can be described by a second-order exponential decay equation. Finally, the overvoltage calculated using the proposed model was compared with those obtained based on Agrawal's model and measurements made using the newly developed intelligent insulator on site. From these comparisons, it could be concluded that the FDTD method with the electromagnetic return-stroke model produces reasonably accurate results of the attenuated oscillation waveform, which can better reproduce the overvoltage on operational distribution lines.</p>\",\"PeriodicalId\":48649,\"journal\":{\"name\":\"High Voltage\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12392\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"High Voltage\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12392\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12392","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

准确模拟架空配电线路的雷电感应过电压有助于防止雷击跳闸事故。本文采用电磁回击模型表示雷电,然后采用三维有限差分时域(FDTD)方法模拟配电线路上的雷电感应过电压,而不采用场线耦合模型。分析了不同接地电导率和配电线路与雷电通道之间不同距离时雷电感应过电压的表现。结果表明,雷击有损地和理想地(σ = ∞)时,线路中心点的过电压波形相似;但波形的峰值幅值在近距离时受土壤导电率的影响。过电压大小与距离之间的关系可以用二阶指数衰减方程来描述。最后,将使用所提出的模型计算出的过电压与根据 Agrawal 模型和使用现场新开发的智能绝缘体测量得出的过电压进行了比较。通过这些比较,可以得出结论:采用电磁回击模型的 FDTD 方法可以产生相当精确的衰减振荡波形结果,从而更好地再现运行中配电线路上的过电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of lightning-induced overvoltage on a 10 kV distribution line based on electromagnetic return-stroke model using finite-difference time-domain

Accurate simulation of lightning-induced overvoltage for overhead distribution lines is helpful to prevent lightning trip accidents. An electromagnetic return-stroke model was used to represent lightning and then a 3D finite-difference time-domain (FDTD) method was adopted to simulate the lightning-induced overvoltage on a distribution line without a field-line coupling model. How lightning-induced overvoltage behave for different ground conductivity and varying distance between the distribution line and the lightning channel was analysed. The results showed that the overvoltage waveforms at the centre point of the line corresponding to lightning strikes on the lossy ground and an ideal ground (σ = ∞) were similar; however, the peak amplitudes of the waveform were affected by soil conductivity at a close distance. The relationship between magnitude of the overvoltage and distance can be described by a second-order exponential decay equation. Finally, the overvoltage calculated using the proposed model was compared with those obtained based on Agrawal's model and measurements made using the newly developed intelligent insulator on site. From these comparisons, it could be concluded that the FDTD method with the electromagnetic return-stroke model produces reasonably accurate results of the attenuated oscillation waveform, which can better reproduce the overvoltage on operational distribution lines.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
High Voltage
High Voltage Energy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍: High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include: Electrical Insulation ● Outdoor, indoor, solid, liquid and gas insulation ● Transient voltages and overvoltage protection ● Nano-dielectrics and new insulation materials ● Condition monitoring and maintenance Discharge and plasmas, pulsed power ● Electrical discharge, plasma generation and applications ● Interactions of plasma with surfaces ● Pulsed power science and technology High-field effects ● Computation, measurements of Intensive Electromagnetic Field ● Electromagnetic compatibility ● Biomedical effects ● Environmental effects and protection High Voltage Engineering ● Design problems, testing and measuring techniques ● Equipment development and asset management ● Smart Grid, live line working ● AC/DC power electronics ● UHV power transmission Special Issues. Call for papers: Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf
期刊最新文献
Research on temperature distribution characteristics of oil-immersed power transformers based on fluid network decoupling On image transformation for partial discharge source identification in vehicle cable terminals of high-speed trains New insights on thermal ageing of electrical insulating oils as revealed from photoluminescence and absorption spectroscopy Energy regulation of impulse current generator modulated DC arc discharge Stress grading system optimisation for an inverter-fed rotating machine
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1