评估预着色和人工着色整体氧化锆的着色再现性和机械性能。

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Operative dentistry Pub Date : 2024-01-01 DOI:10.2341/23-016-L
I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari
{"title":"评估预着色和人工着色整体氧化锆的着色再现性和机械性能。","authors":"I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari","doi":"10.2341/23-016-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.</p><p><strong>Methods and materials: </strong>Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).</p><p><strong>Results: </strong>Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).</p><p><strong>Conclusions: </strong>White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":"49 1","pages":"110-116"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Shade Reproducibility and Mechanical Properties of Preshaded and Manually Shaded Monolithic Zirconia.\",\"authors\":\"I A Albakri, Z AlHorani, M Hatamleh, W M Al-Omari\",\"doi\":\"10.2341/23-016-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.</p><p><strong>Methods and materials: </strong>Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).</p><p><strong>Results: </strong>Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).</p><p><strong>Conclusions: </strong>White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":\"49 1\",\"pages\":\"110-116\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/23-016-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-016-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在探讨与预先着色的同种材料氧化锆块相比,人工着色四种材料的空白整体氧化锆块对其色泽再现性、抗弯强度和表面粗糙度的影响:从四种氧化锆系统的着色块和非着色块上磨制出八个圆盘形试样(直径=12 毫米;高=2 毫米)和八个条形试样(25×2×2 毫米):Ceramill、Kerox、White Peaks 和 Dental Direkt。总共制作了 128 个试样。每个系统的非阴影试样都根据 A2 阴影着色。使用接触式轮廓仪测量表面粗糙度(Ra)。色差根据 CIEDE2000 公式计算。条形试样以 1 毫米/分钟的十字头速度进行三点弯曲测试,加载至断裂。数据分析采用单因素方差分析(ANOVA)和Tukey事后检验(P=0.05):与预着色块相比,人工着色影响了三种材料的表面粗糙度、色差和抗折强度(p0.05)。Ra 值范围为 1.1-1.9;三种材料不受影响(p>0.05)。Kerox 预着色砌块最光滑(p0.05)。在所有测试材料中,预着色和人工着色砌块的 DE 都是可感知和不可接受的(ΔE>1.8)。人工着色降低了 Ceramill 和 Dental Direkt 的抗折强度(p0.05):白色峰值不受着色技术的影响。着色对 Ceramill 抗折强度和颜色再现性有负面影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Shade Reproducibility and Mechanical Properties of Preshaded and Manually Shaded Monolithic Zirconia.

Objectives: This study aimed to investigate the effect of manual coloring of blank monolithic zirconia blocks of four materials on their shade reproducibility, flexural strength, and surface roughness as compared with preshaded blocks of the same material.

Methods and materials: Eight disc-shaped specimens (diameter=12mm; height=2mm) and eight bar-shaped specimens (25×2×2 mm) were milled from the shaded and non-shaded blocks of the four zirconia systems: Ceramill, Kerox, White Peaks, and Dental Direkt. In total, 128 specimens were fabricated. The non-shaded specimens of each system were coloured according to A2 shade. The surface roughness (Ra) was measured using a contact profilometer. Color difference was calculated according to the CIEDE2000 formula. The bar-shaped specimens were loaded to fracture following three-point bend testing at 1 mm/minute crosshead speed. Data were analysed following one-way analysis of variance (ANOVA), and the Tukey post-hoc test (p=0.05).

Results: Manual-coloring affected the surface roughness, color difference, and flexural strength of three materials in comparison to their preshaded blocks (p<0.05). White Peaks was not affected (p>0.05). Ra values ranged from 1.1-1.9; three materials were not affected (p>0.05). Kerox preshaded blocks were the smoothest (p<0.05) but became the roughest once colored (p<0.05). White Peaks and Dental Direkt materials had preshaded blocks matching the A2 guide-tab (p>0.05). DE was perceptible and unacceptable for the preshaded and manually shaded blocks of all materials tested (ΔE>1.8). While manual coloring reduced flexural strength of Ceramill and Dental Direkt (p<0.05), flexural strength was retained by Kerox and White Peaks (p>0.05).

Conclusions: White Peaks was not affected by the coloring technique. Coloring had negative effects on Ceramill flexural strength and color reproducibility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
期刊最新文献
3D Printed Dual Reduction Guide: A Feasible Alternative for Conservative Gingivectomy and Minimally Invasive Preparation for Ceramic Veneers. A Novel Isolation Technique Using Polytetrafluoroethylene Tape and Split Dam Isolation for Cementation in Bridge Restorations. Bacterial Adhesion and In Situ Biodegradation of Preheated Resin Composite Used as a Luting Agent for Indirect Restorations. Biomechanical and Physical Characteristics of Dental Dam Sheets Used for Absolute Isolation. Bonding and Cleaning Effects of Irrigation Protocols Using Calcium Hypochlorite on the Post-space Radicular Dentin.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1