{"title":"在笔状肌物理模型中,建筑齿轮比取决于致动器间距。","authors":"David A Sleboda, Thomas J Roberts, Emanuel Azizi","doi":"10.1088/1748-3190/ad1b2b","DOIUrl":null,"url":null,"abstract":"<p><p>Pennate muscles are defined by the architectural arrangement of their muscle fibers, which run at an angle to the primary axis of muscle shortening. Pennation angles can vary dynamically over the course of individual contractions, influencing the speed and distance of muscle shortening. Despite their relevance to muscle performance, the physical mechanisms that drive dynamic changes in pennation angle remain poorly understood. Muscle fibers bulge radially as they shorten, a consequence of maintaining a constant internal fluid volume, and we hypothesized that radial interactions between tightly packed muscle fibers are essential to dynamic pennation angle changes. To explore this, we built physical models of pennate muscles in which the radial distance between fiber-like actuators could be experimentally altered. Models were built from pennate arrays of McKibben actuators, a type of pneumatic actuator that forcefully shortens and bulges radially when inflated with compressed air. Consistent with past studies of biological muscle and engineered pennate actuators, we found that the magnitude of pennation angle change during contraction varied with load. Importantly, however, we found that pennation angle changes were also strongly influenced by the radial distance between neighboring McKibben actuators. Increasing the radial distance between neighboring actuators reduced pennation angle change during contraction and effectively eliminated variable responses to load. Radial interactions between muscle fibers are rarely considered in theoretical and experimental analyses of pennate muscle; however, these findings suggest that radial interactions between fibers drive pennation angle changes and influence pennate muscle performance. Our results provide insight into the fundamental mechanism underlying dynamic pennation angle changes in biological muscle and highlight design considerations that can inform the development of engineered pennate arrays.</p>","PeriodicalId":55377,"journal":{"name":"Bioinspiration & Biomimetics","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10876153/pdf/","citationCount":"0","resultStr":"{\"title\":\"Architectural gear ratio depends on actuator spacing in a physical model of pennate muscle.\",\"authors\":\"David A Sleboda, Thomas J Roberts, Emanuel Azizi\",\"doi\":\"10.1088/1748-3190/ad1b2b\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Pennate muscles are defined by the architectural arrangement of their muscle fibers, which run at an angle to the primary axis of muscle shortening. Pennation angles can vary dynamically over the course of individual contractions, influencing the speed and distance of muscle shortening. Despite their relevance to muscle performance, the physical mechanisms that drive dynamic changes in pennation angle remain poorly understood. Muscle fibers bulge radially as they shorten, a consequence of maintaining a constant internal fluid volume, and we hypothesized that radial interactions between tightly packed muscle fibers are essential to dynamic pennation angle changes. To explore this, we built physical models of pennate muscles in which the radial distance between fiber-like actuators could be experimentally altered. Models were built from pennate arrays of McKibben actuators, a type of pneumatic actuator that forcefully shortens and bulges radially when inflated with compressed air. Consistent with past studies of biological muscle and engineered pennate actuators, we found that the magnitude of pennation angle change during contraction varied with load. Importantly, however, we found that pennation angle changes were also strongly influenced by the radial distance between neighboring McKibben actuators. Increasing the radial distance between neighboring actuators reduced pennation angle change during contraction and effectively eliminated variable responses to load. Radial interactions between muscle fibers are rarely considered in theoretical and experimental analyses of pennate muscle; however, these findings suggest that radial interactions between fibers drive pennation angle changes and influence pennate muscle performance. Our results provide insight into the fundamental mechanism underlying dynamic pennation angle changes in biological muscle and highlight design considerations that can inform the development of engineered pennate arrays.</p>\",\"PeriodicalId\":55377,\"journal\":{\"name\":\"Bioinspiration & Biomimetics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10876153/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioinspiration & Biomimetics\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1088/1748-3190/ad1b2b\",\"RegionNum\":3,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioinspiration & Biomimetics","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1088/1748-3190/ad1b2b","RegionNum":3,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Architectural gear ratio depends on actuator spacing in a physical model of pennate muscle.
Pennate muscles are defined by the architectural arrangement of their muscle fibers, which run at an angle to the primary axis of muscle shortening. Pennation angles can vary dynamically over the course of individual contractions, influencing the speed and distance of muscle shortening. Despite their relevance to muscle performance, the physical mechanisms that drive dynamic changes in pennation angle remain poorly understood. Muscle fibers bulge radially as they shorten, a consequence of maintaining a constant internal fluid volume, and we hypothesized that radial interactions between tightly packed muscle fibers are essential to dynamic pennation angle changes. To explore this, we built physical models of pennate muscles in which the radial distance between fiber-like actuators could be experimentally altered. Models were built from pennate arrays of McKibben actuators, a type of pneumatic actuator that forcefully shortens and bulges radially when inflated with compressed air. Consistent with past studies of biological muscle and engineered pennate actuators, we found that the magnitude of pennation angle change during contraction varied with load. Importantly, however, we found that pennation angle changes were also strongly influenced by the radial distance between neighboring McKibben actuators. Increasing the radial distance between neighboring actuators reduced pennation angle change during contraction and effectively eliminated variable responses to load. Radial interactions between muscle fibers are rarely considered in theoretical and experimental analyses of pennate muscle; however, these findings suggest that radial interactions between fibers drive pennation angle changes and influence pennate muscle performance. Our results provide insight into the fundamental mechanism underlying dynamic pennation angle changes in biological muscle and highlight design considerations that can inform the development of engineered pennate arrays.
期刊介绍:
Bioinspiration & Biomimetics publishes research involving the study and distillation of principles and functions found in biological systems that have been developed through evolution, and application of this knowledge to produce novel and exciting basic technologies and new approaches to solving scientific problems. It provides a forum for interdisciplinary research which acts as a pipeline, facilitating the two-way flow of ideas and understanding between the extensive bodies of knowledge of the different disciplines. It has two principal aims: to draw on biology to enrich engineering and to draw from engineering to enrich biology.
The journal aims to include input from across all intersecting areas of both fields. In biology, this would include work in all fields from physiology to ecology, with either zoological or botanical focus. In engineering, this would include both design and practical application of biomimetic or bioinspired devices and systems. Typical areas of interest include:
Systems, designs and structure
Communication and navigation
Cooperative behaviour
Self-organizing biological systems
Self-healing and self-assembly
Aerial locomotion and aerospace applications of biomimetics
Biomorphic surface and subsurface systems
Marine dynamics: swimming and underwater dynamics
Applications of novel materials
Biomechanics; including movement, locomotion, fluidics
Cellular behaviour
Sensors and senses
Biomimetic or bioinformed approaches to geological exploration.