ENTA 墙体框架系统的结构性能测试和有限元分析

Hyoseo An, Taesang Ahn, Sumin Kang, Jiuk Shin, Kihak Lee
{"title":"ENTA 墙体框架系统的结构性能测试和有限元分析","authors":"Hyoseo An, Taesang Ahn, Sumin Kang, Jiuk Shin, Kihak Lee","doi":"10.9798/kosham.2023.23.6.1","DOIUrl":null,"url":null,"abstract":"This study rigorously assessed the structural performance of the wall frame system through a combination of experimentation and simulation under cyclic loading. Hence, three distinct specimens were developed: the original frame (referred to as the “as-built frame”), the retrofitted frame with ENTA damper system (referred to as “ENTA-W”), and the retrofitted frame with both ENTA damper system and steel frame (referred to as “ENTA-WR’). The experimental findings revealed that the retrofitted frames outperformed the as-built frame regarding energy dissipation ability, initial stiffness, and maximum load capacity. A detailed analysis and comparison between experimental and finite element analysis results were conducted. Notably, disparities between the experimental and analytical outcomes were lower than or near five percent regarding energy dissipation capacity, initial stiffness, and maximum strength. Moreover, the anticipated failure pattern of the concrete section and the stress distribution of the reinforcing bar closely mirrored those observed in the experiment.","PeriodicalId":416980,"journal":{"name":"Journal of the Korean Society of Hazard Mitigation","volume":" 1118","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Structural Performance Testing and Finite Element Analysis of the ENTA Wall Frame System\",\"authors\":\"Hyoseo An, Taesang Ahn, Sumin Kang, Jiuk Shin, Kihak Lee\",\"doi\":\"10.9798/kosham.2023.23.6.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study rigorously assessed the structural performance of the wall frame system through a combination of experimentation and simulation under cyclic loading. Hence, three distinct specimens were developed: the original frame (referred to as the “as-built frame”), the retrofitted frame with ENTA damper system (referred to as “ENTA-W”), and the retrofitted frame with both ENTA damper system and steel frame (referred to as “ENTA-WR’). The experimental findings revealed that the retrofitted frames outperformed the as-built frame regarding energy dissipation ability, initial stiffness, and maximum load capacity. A detailed analysis and comparison between experimental and finite element analysis results were conducted. Notably, disparities between the experimental and analytical outcomes were lower than or near five percent regarding energy dissipation capacity, initial stiffness, and maximum strength. Moreover, the anticipated failure pattern of the concrete section and the stress distribution of the reinforcing bar closely mirrored those observed in the experiment.\",\"PeriodicalId\":416980,\"journal\":{\"name\":\"Journal of the Korean Society of Hazard Mitigation\",\"volume\":\" 1118\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Society of Hazard Mitigation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9798/kosham.2023.23.6.1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Society of Hazard Mitigation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9798/kosham.2023.23.6.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究通过实验和模拟相结合的方法,严格评估了墙体框架系统在循环荷载下的结构性能。因此,开发了三种不同的试样:原始框架(称为 "原建框架")、带有 ENTA 阻尼器系统的改装框架(称为 "ENTA-W")以及带有 ENTA 阻尼器系统和钢框架的改装框架(称为 "ENTA-WR")。实验结果表明,改造后的框架在消能能力、初始刚度和最大承载能力方面均优于原建框架。对实验结果和有限元分析结果进行了详细分析和比较。值得注意的是,在消能能力、初始刚度和最大强度方面,实验结果与分析结果之间的差距低于或接近 5%。此外,混凝土截面的预期破坏模式和钢筋的应力分布也与实验中观察到的情况十分吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Structural Performance Testing and Finite Element Analysis of the ENTA Wall Frame System
This study rigorously assessed the structural performance of the wall frame system through a combination of experimentation and simulation under cyclic loading. Hence, three distinct specimens were developed: the original frame (referred to as the “as-built frame”), the retrofitted frame with ENTA damper system (referred to as “ENTA-W”), and the retrofitted frame with both ENTA damper system and steel frame (referred to as “ENTA-WR’). The experimental findings revealed that the retrofitted frames outperformed the as-built frame regarding energy dissipation ability, initial stiffness, and maximum load capacity. A detailed analysis and comparison between experimental and finite element analysis results were conducted. Notably, disparities between the experimental and analytical outcomes were lower than or near five percent regarding energy dissipation capacity, initial stiffness, and maximum strength. Moreover, the anticipated failure pattern of the concrete section and the stress distribution of the reinforcing bar closely mirrored those observed in the experiment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Study on the Statistical Analysis and Artificial Intelligence Model to Improve the Reliability of Safety Inspection Prediction of the DO Factor at Bugok Bridge, Oncheoncheon, Using Deep Learning Impact of Disaster on Household Expenditures Using a Difference-in-Difference Analysis Occupant Load Factor Calculation in Neighborhood Living Facilities while Performance-Based Design A Study on Establishing Procedures and Display Design for the Development of the Disaster Management System using Satellite Imagery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1