Muhammad Arif Budiyanto, Muhammad Bukhari Robbani, Gerry Liston Putra, Achmad Riadi, Gunawan, Muhammad Iqbal
{"title":"利用计算流体动力学对装载鲣鱼的冷藏集装箱进行气流分布分析","authors":"Muhammad Arif Budiyanto, Muhammad Bukhari Robbani, Gerry Liston Putra, Achmad Riadi, Gunawan, Muhammad Iqbal","doi":"10.37934/cfdl.16.2.6775","DOIUrl":null,"url":null,"abstract":"In the transportation of skipjack tuna to various destination countries, it is crucial to ensure that the skipjack tuna persists and remains of high quality. This study aims to analyse the airflow distribution inside the reefer container with the cargo load of skipjack tuna. The analysis carries out the computational fluid dynamics method to obtain appropriate airflow settings and investigate the temperature distribution inside reefer containers. The designed reefer container is 40ft with detailed structural variables of the T-bar and flat floor. The simulation result shows reefer containers that use the T-bar floor provide offer a thorough airflow distribution to cooling pallet stacks with full load conditions. The finding of the simulation results is the airflow rate of 5 m/s and the inlet temperature of -6°C will provide optimal cooling distribution.","PeriodicalId":9736,"journal":{"name":"CFD Letters","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Airflow Distribution Analysis of Reefer Container with Skipjack Tuna Load using Computational Fluid Dynamics\",\"authors\":\"Muhammad Arif Budiyanto, Muhammad Bukhari Robbani, Gerry Liston Putra, Achmad Riadi, Gunawan, Muhammad Iqbal\",\"doi\":\"10.37934/cfdl.16.2.6775\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the transportation of skipjack tuna to various destination countries, it is crucial to ensure that the skipjack tuna persists and remains of high quality. This study aims to analyse the airflow distribution inside the reefer container with the cargo load of skipjack tuna. The analysis carries out the computational fluid dynamics method to obtain appropriate airflow settings and investigate the temperature distribution inside reefer containers. The designed reefer container is 40ft with detailed structural variables of the T-bar and flat floor. The simulation result shows reefer containers that use the T-bar floor provide offer a thorough airflow distribution to cooling pallet stacks with full load conditions. The finding of the simulation results is the airflow rate of 5 m/s and the inlet temperature of -6°C will provide optimal cooling distribution.\",\"PeriodicalId\":9736,\"journal\":{\"name\":\"CFD Letters\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CFD Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37934/cfdl.16.2.6775\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CFD Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37934/cfdl.16.2.6775","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Mathematics","Score":null,"Total":0}
引用次数: 0
摘要
在将鲣鱼运往不同目的地国家的运输过程中,确保鲣鱼的品质和质量至关重要。本研究旨在分析装载鲣鱼的冷藏集装箱内的气流分布。分析采用计算流体动力学方法,以获得适当的气流设置,并研究冷藏集装箱内的温度分布。设计的冷藏集装箱为 40 英尺,具有 T 形杆和平底的详细结构变量。模拟结果表明,使用 T 形杆地板的冷藏集装箱可在满载条件下为冷却托盘堆提供全面的气流分布。模拟结果表明,5 米/秒的气流速度和 -6°C 的入口温度将提供最佳的冷却分布。
Airflow Distribution Analysis of Reefer Container with Skipjack Tuna Load using Computational Fluid Dynamics
In the transportation of skipjack tuna to various destination countries, it is crucial to ensure that the skipjack tuna persists and remains of high quality. This study aims to analyse the airflow distribution inside the reefer container with the cargo load of skipjack tuna. The analysis carries out the computational fluid dynamics method to obtain appropriate airflow settings and investigate the temperature distribution inside reefer containers. The designed reefer container is 40ft with detailed structural variables of the T-bar and flat floor. The simulation result shows reefer containers that use the T-bar floor provide offer a thorough airflow distribution to cooling pallet stacks with full load conditions. The finding of the simulation results is the airflow rate of 5 m/s and the inlet temperature of -6°C will provide optimal cooling distribution.