用于确定 LED 灯具时间光伪的数字实现方法

V. Mantela, R. Nordlund, J. Askola, P. Kärhä, E. Ikonen
{"title":"用于确定 LED 灯具时间光伪的数字实现方法","authors":"V. Mantela, R. Nordlund, J. Askola, P. Kärhä, E. Ikonen","doi":"10.1177/14771535231212404","DOIUrl":null,"url":null,"abstract":"Flicker and stroboscopic effects caused by a temporally modulated light source may be harmful for the human visual system. Standardized measurement methods have been developed for the related temporal light artefacts of LED luminaires. It was found out that the performance of the International Electrotechnical Commission (IEC) recommended flickermeter implementation is highly dependent on sampling frequency. Novel digital implementations for the flickermeter and stroboscopic effect visibility measure (SVM) were created to remove any inaccuracies. The performance of the novel Aalto implementations does not depend on the sampling frequency when running the test waveforms of the IEC standard through the implementations. As compared with the IEC recommended digital implementations, Aalto flickermeter decreases the average error related to the test waveforms from −0.05 to +0.003, and Aalto SVM meter also decreases the average error by almost two orders of magnitude.","PeriodicalId":269493,"journal":{"name":"Lighting Research & Technology","volume":"76 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Digital implementations for determination of temporal light artefacts of LED luminaires\",\"authors\":\"V. Mantela, R. Nordlund, J. Askola, P. Kärhä, E. Ikonen\",\"doi\":\"10.1177/14771535231212404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flicker and stroboscopic effects caused by a temporally modulated light source may be harmful for the human visual system. Standardized measurement methods have been developed for the related temporal light artefacts of LED luminaires. It was found out that the performance of the International Electrotechnical Commission (IEC) recommended flickermeter implementation is highly dependent on sampling frequency. Novel digital implementations for the flickermeter and stroboscopic effect visibility measure (SVM) were created to remove any inaccuracies. The performance of the novel Aalto implementations does not depend on the sampling frequency when running the test waveforms of the IEC standard through the implementations. As compared with the IEC recommended digital implementations, Aalto flickermeter decreases the average error related to the test waveforms from −0.05 to +0.003, and Aalto SVM meter also decreases the average error by almost two orders of magnitude.\",\"PeriodicalId\":269493,\"journal\":{\"name\":\"Lighting Research & Technology\",\"volume\":\"76 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lighting Research & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/14771535231212404\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting Research & Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/14771535231212404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由时间调制光源引起的闪烁和频闪效应可能对人类视觉系统有害。针对 LED 灯具的相关时间光伪影,已经开发出标准化的测量方法。研究发现,国际电工委员会(IEC)推荐的闪烁计的性能在很大程度上取决于采样频率。为了消除误差,我们创建了闪烁计和频闪效应能见度测量(SVM)的新型数字实现方法。将 IEC 标准的测试波形通过新的 Aalto 实现时,其性能与采样频率无关。与 IEC 推荐的数字实现相比,Aalto 闪烁计将与测试波形相关的平均误差从 -0.05 降低到 +0.003,Aalto SVM 计也将平均误差降低了近两个数量级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Digital implementations for determination of temporal light artefacts of LED luminaires
Flicker and stroboscopic effects caused by a temporally modulated light source may be harmful for the human visual system. Standardized measurement methods have been developed for the related temporal light artefacts of LED luminaires. It was found out that the performance of the International Electrotechnical Commission (IEC) recommended flickermeter implementation is highly dependent on sampling frequency. Novel digital implementations for the flickermeter and stroboscopic effect visibility measure (SVM) were created to remove any inaccuracies. The performance of the novel Aalto implementations does not depend on the sampling frequency when running the test waveforms of the IEC standard through the implementations. As compared with the IEC recommended digital implementations, Aalto flickermeter decreases the average error related to the test waveforms from −0.05 to +0.003, and Aalto SVM meter also decreases the average error by almost two orders of magnitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Defining daytime in the day-dark approach to measuring the pedestrian reassurance of road lighting Editorial: The many faces of sustainability in lighting research Recommendations for light-dosimetry field studies based on a meta-analysis of personal light levels of office workers Opinion: Embracing ‘anthropogenic’ over ‘artificial’ light at night Opinion: The role of outdoor lighting with pedestrian reassurance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1