{"title":"基于 D 轴磁网络模型的永磁同步电机多类型退磁故障鲁棒诊断(使用磁场重构技术","authors":"Wang He, Jun Hang, Shichuan Ding","doi":"10.1049/elp2.12391","DOIUrl":null,"url":null,"abstract":"<p>Demagnetisation fault (DF) is a common rotor fault in the permanent magnet synchronous motor (PMSM). DF can cause obvious changes in the magnetic field of PMSMs. As a result, previous DF diagnosis methods mainly depends on magnetic field analysis. However, conventional analysis methods based on the magnetic potential-permeability method, sub-domain method and magnetic equivalent circuit method are not suitable for DF condition. In addition, DF diagnosis is further complicated by various operating conditions. To address these issues, a robust DF diagnosis method is proposed for PMSM based on <i>d</i>-axis magnetic network model using magnetic field reconstruction. The proposed fault diagnosis method employs magnetic field reconstruction to obtain the radial air-gap flux density under the open-circuit condition. Subsequently, a <i>d</i>-axis magnetic network is established to solve the demagnetisation coefficient matrix in the DF state. Finally, the effectiveness of the proposed method is validated through simulations and experiments. Both results demonstrate that the proposed method can accurately recognise uniform DF and partial DF with multiple demagnetised permanent magnets, exhibiting great robustness against different operating conditions.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12391","citationCount":"0","resultStr":"{\"title\":\"Enhanced robust diagnosis of multiple-type demagnetisation fault for permanent magnet synchronous motor based on D-axis magnetic network model using magnetic field reconstruction\",\"authors\":\"Wang He, Jun Hang, Shichuan Ding\",\"doi\":\"10.1049/elp2.12391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Demagnetisation fault (DF) is a common rotor fault in the permanent magnet synchronous motor (PMSM). DF can cause obvious changes in the magnetic field of PMSMs. As a result, previous DF diagnosis methods mainly depends on magnetic field analysis. However, conventional analysis methods based on the magnetic potential-permeability method, sub-domain method and magnetic equivalent circuit method are not suitable for DF condition. In addition, DF diagnosis is further complicated by various operating conditions. To address these issues, a robust DF diagnosis method is proposed for PMSM based on <i>d</i>-axis magnetic network model using magnetic field reconstruction. The proposed fault diagnosis method employs magnetic field reconstruction to obtain the radial air-gap flux density under the open-circuit condition. Subsequently, a <i>d</i>-axis magnetic network is established to solve the demagnetisation coefficient matrix in the DF state. Finally, the effectiveness of the proposed method is validated through simulations and experiments. Both results demonstrate that the proposed method can accurately recognise uniform DF and partial DF with multiple demagnetised permanent magnets, exhibiting great robustness against different operating conditions.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-11-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12391\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12391\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12391","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Enhanced robust diagnosis of multiple-type demagnetisation fault for permanent magnet synchronous motor based on D-axis magnetic network model using magnetic field reconstruction
Demagnetisation fault (DF) is a common rotor fault in the permanent magnet synchronous motor (PMSM). DF can cause obvious changes in the magnetic field of PMSMs. As a result, previous DF diagnosis methods mainly depends on magnetic field analysis. However, conventional analysis methods based on the magnetic potential-permeability method, sub-domain method and magnetic equivalent circuit method are not suitable for DF condition. In addition, DF diagnosis is further complicated by various operating conditions. To address these issues, a robust DF diagnosis method is proposed for PMSM based on d-axis magnetic network model using magnetic field reconstruction. The proposed fault diagnosis method employs magnetic field reconstruction to obtain the radial air-gap flux density under the open-circuit condition. Subsequently, a d-axis magnetic network is established to solve the demagnetisation coefficient matrix in the DF state. Finally, the effectiveness of the proposed method is validated through simulations and experiments. Both results demonstrate that the proposed method can accurately recognise uniform DF and partial DF with multiple demagnetised permanent magnets, exhibiting great robustness against different operating conditions.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.