小梁切除术后青光眼患者经巩膜固定眼内透镜后屈光度的预测准确性

Dong Seon Kim, B. Park, H. Kwon, Sung Who Park, I. Byon
{"title":"小梁切除术后青光眼患者经巩膜固定眼内透镜后屈光度的预测准确性","authors":"Dong Seon Kim, B. Park, H. Kwon, Sung Who Park, I. Byon","doi":"10.3341/jkos.2023.64.11.1022","DOIUrl":null,"url":null,"abstract":"Purpose: To investigate the predictive accuracy of refraction and any change in intraocular pressure (IOP) after transscleral fixation of intraocular lenses (IOLs) in trabeculectomized eyes with glaucoma.Methods: We retrospectively reviewed the medical records of glaucoma patients who underwent trabeculectomy, followed by transscleral fixation of dislocated IOLs combined with vitrectomy. The refraction predicted by the SRK/T formula and the postoperative refraction were converted into spherical equivalents. Predictive refraction accuracies were analyzed when the differences between the two values were within ± 0.5 diopters (D) and ± 1.0 D. The IOP was measured before and after surgery.Results: Eleven eyes of 11 men (mean age, 67.27 ± 10.55 years) were included. The mean axial length was 23.64 ± 1.26 mm; the mean predicted and postoperative refractions were -0.02 ± 0.46 D and -0.80 ± 0.98 D, respectively (p = 0.029). The refractive outcome was more myopic (by -0.78 ± 1.11 D) than predicted. The predictive accuracies were 36.4% and 72.7% when the differences were ± 0.5 and ± 1.0 D, respectively. The IOP did not change during follow-up (13.18 ± 4.56, 12.82 ± 5.88, and 12.73 ± 4.58 mmHg at baseline, 1 week, and 3 months, respectively).Conclusions: In trabeculectomized eyes, transscleral IOL fixation did not affect the IOP, but the refractive outcome was more myopic than predicted. This difference should be considered when choosing IOL target power.","PeriodicalId":504314,"journal":{"name":"Journal of the Korean Ophthalmological Society","volume":"27 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Predictive Accuracy of Refraction after Transscleral Fixation of Intraocular Lenses in Trabeculectomized Eyes with Glaucoma\",\"authors\":\"Dong Seon Kim, B. Park, H. Kwon, Sung Who Park, I. Byon\",\"doi\":\"10.3341/jkos.2023.64.11.1022\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: To investigate the predictive accuracy of refraction and any change in intraocular pressure (IOP) after transscleral fixation of intraocular lenses (IOLs) in trabeculectomized eyes with glaucoma.Methods: We retrospectively reviewed the medical records of glaucoma patients who underwent trabeculectomy, followed by transscleral fixation of dislocated IOLs combined with vitrectomy. The refraction predicted by the SRK/T formula and the postoperative refraction were converted into spherical equivalents. Predictive refraction accuracies were analyzed when the differences between the two values were within ± 0.5 diopters (D) and ± 1.0 D. The IOP was measured before and after surgery.Results: Eleven eyes of 11 men (mean age, 67.27 ± 10.55 years) were included. The mean axial length was 23.64 ± 1.26 mm; the mean predicted and postoperative refractions were -0.02 ± 0.46 D and -0.80 ± 0.98 D, respectively (p = 0.029). The refractive outcome was more myopic (by -0.78 ± 1.11 D) than predicted. The predictive accuracies were 36.4% and 72.7% when the differences were ± 0.5 and ± 1.0 D, respectively. The IOP did not change during follow-up (13.18 ± 4.56, 12.82 ± 5.88, and 12.73 ± 4.58 mmHg at baseline, 1 week, and 3 months, respectively).Conclusions: In trabeculectomized eyes, transscleral IOL fixation did not affect the IOP, but the refractive outcome was more myopic than predicted. This difference should be considered when choosing IOL target power.\",\"PeriodicalId\":504314,\"journal\":{\"name\":\"Journal of the Korean Ophthalmological Society\",\"volume\":\"27 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Korean Ophthalmological Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3341/jkos.2023.64.11.1022\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2023.64.11.1022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究小梁切除术后青光眼患者经巩膜固定人工晶体(IOL)后屈光度的预测准确性以及眼压(IOP)的任何变化:我们回顾性地查看了接受小梁切除术、经巩膜固定脱位人工晶体术和玻璃体切除术的青光眼患者的病历。将 SRK/T 公式预测的屈光度和术后屈光度转换为球面当量。当两个数值的差异在± 0.5屈光度(D)和± 1.0屈光度(D)范围内时,对预测屈光度的准确性进行分析:结果:共纳入 11 名男性的 11 只眼睛(平均年龄为 67.27 ± 10.55 岁)。平均轴长为 23.64 ± 1.26 mm;预测屈光度和术后屈光度分别为 -0.02 ± 0.46 D 和 -0.80 ± 0.98 D(p = 0.029)。屈光结果比预测值更近视(-0.78 ± 1.11 D)。当差异为 ± 0.5 和 ± 1.0 D 时,预测准确率分别为 36.4% 和 72.7%。随访期间,眼压没有变化(基线、1 周和 3 个月时分别为 13.18 ± 4.56、12.82 ± 5.88 和 12.73 ± 4.58 mmHg):在小梁切除的眼睛中,经巩膜固定人工晶体不会影响眼压,但屈光结果比预测的更近视。在选择人工晶体目标功率时应考虑到这一差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Predictive Accuracy of Refraction after Transscleral Fixation of Intraocular Lenses in Trabeculectomized Eyes with Glaucoma
Purpose: To investigate the predictive accuracy of refraction and any change in intraocular pressure (IOP) after transscleral fixation of intraocular lenses (IOLs) in trabeculectomized eyes with glaucoma.Methods: We retrospectively reviewed the medical records of glaucoma patients who underwent trabeculectomy, followed by transscleral fixation of dislocated IOLs combined with vitrectomy. The refraction predicted by the SRK/T formula and the postoperative refraction were converted into spherical equivalents. Predictive refraction accuracies were analyzed when the differences between the two values were within ± 0.5 diopters (D) and ± 1.0 D. The IOP was measured before and after surgery.Results: Eleven eyes of 11 men (mean age, 67.27 ± 10.55 years) were included. The mean axial length was 23.64 ± 1.26 mm; the mean predicted and postoperative refractions were -0.02 ± 0.46 D and -0.80 ± 0.98 D, respectively (p = 0.029). The refractive outcome was more myopic (by -0.78 ± 1.11 D) than predicted. The predictive accuracies were 36.4% and 72.7% when the differences were ± 0.5 and ± 1.0 D, respectively. The IOP did not change during follow-up (13.18 ± 4.56, 12.82 ± 5.88, and 12.73 ± 4.58 mmHg at baseline, 1 week, and 3 months, respectively).Conclusions: In trabeculectomized eyes, transscleral IOL fixation did not affect the IOP, but the refractive outcome was more myopic than predicted. This difference should be considered when choosing IOL target power.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Initial Factors Associated with Resistance to Intravitreal Aflibercept Injection in Polypoidal Choroidal Vasculopathy Three Familial Cases of Stickler Syndrome: A Case Report One-year Clinical Outcome of Topical Bromfenac in Central Serous Chorioretinopathy A Case of Atypical Cytomegalovirus Corneal Endotheliitis after Intravitreal Triamcinolone Injection Correction of Internal Astigmatism Using Toric Scleral Contact Lens after Implantable Collamer Lens Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1