牙齿活动度对传统印模准确性的影响:试点研究。

Bowen Lu, Junwei Zhu, Linlin Shao, Qing Yu
{"title":"牙齿活动度对传统印模准确性的影响:试点研究。","authors":"Bowen Lu, Junwei Zhu, Linlin Shao, Qing Yu","doi":"10.11607/ijp.7774","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To study the influence of tooth mobility on the accuracy of conventional impressions.</p><p><strong>Materials and methods: </strong>In total, 10 patients with mobile anterior teeth and 10 healthy patients were treated with conventional impressions and intraoral digital impressions. The digital impression group was recorded as standard data, the mobile teeth group was recorded as the experimental group, and the healthy anterior teeth group was recorded as the control group. We imported digital impression and irreversible hydrocolloid impression files into Geomagic Wrap and marked reference points to execute N-point alignment, then we recorded the coordinates. Paired-samples t test was used to analyze whether the point coordinates of mobile teeth were statistically significant (a = .05). One-way ANOVA was used to analyze whether there was a relationship between coordinate differences and tooth mobility in the distal, coronal, and buccal directions (a = .05).</p><p><strong>Results: </strong>In the buccal and coronal directions, the difference was statistically significant between the conventional and digital impression groups. In the buccal direction, the accuracy differences of I-degree and II-degree mobile teeth were 0.149 mm and 0.401 mm, respectively. In the coronal direction, the differences were 0.128 mm and 0.233 mm, respectively. Meanwhile, ANOVA analysis showed that there was a relationship between point coordinate difference and tooth mobility in the buccal and coronal directions.</p><p><strong>Conclusions: </strong>Conventional impressions can influence the accuracy of mobile tooth impressions. Therefore, digital impressions should be adopted for mobile teeth impressions.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"232"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Tooth Mobility on the Accuracy of Conventional Impressions: A Pilot Study.\",\"authors\":\"Bowen Lu, Junwei Zhu, Linlin Shao, Qing Yu\",\"doi\":\"10.11607/ijp.7774\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To study the influence of tooth mobility on the accuracy of conventional impressions.</p><p><strong>Materials and methods: </strong>In total, 10 patients with mobile anterior teeth and 10 healthy patients were treated with conventional impressions and intraoral digital impressions. The digital impression group was recorded as standard data, the mobile teeth group was recorded as the experimental group, and the healthy anterior teeth group was recorded as the control group. We imported digital impression and irreversible hydrocolloid impression files into Geomagic Wrap and marked reference points to execute N-point alignment, then we recorded the coordinates. Paired-samples t test was used to analyze whether the point coordinates of mobile teeth were statistically significant (a = .05). One-way ANOVA was used to analyze whether there was a relationship between coordinate differences and tooth mobility in the distal, coronal, and buccal directions (a = .05).</p><p><strong>Results: </strong>In the buccal and coronal directions, the difference was statistically significant between the conventional and digital impression groups. In the buccal direction, the accuracy differences of I-degree and II-degree mobile teeth were 0.149 mm and 0.401 mm, respectively. In the coronal direction, the differences were 0.128 mm and 0.233 mm, respectively. Meanwhile, ANOVA analysis showed that there was a relationship between point coordinate difference and tooth mobility in the buccal and coronal directions.</p><p><strong>Conclusions: </strong>Conventional impressions can influence the accuracy of mobile tooth impressions. Therefore, digital impressions should be adopted for mobile teeth impressions.</p>\",\"PeriodicalId\":94232,\"journal\":{\"name\":\"The International journal of prosthodontics\",\"volume\":\"0 0\",\"pages\":\"232\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of prosthodontics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ijp.7774\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.7774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究牙齿移动对传统印模精度的影响:研究牙齿移动对传统印模精度的影响。材料和方法:10 名前牙移动患者和 10 名健康患者分别接受传统印模和口腔内数字印模治疗。数字印模组记录为标准数据,活动牙组记录为实验组,健康前牙组记录为对照组。我们将数字印模和不可逆水胶体印模文件导入 Geomagic Wrap,并标记参考点,执行 N 点对齐,然后记录坐标。采用配对样本 T 检验分析移动牙齿的点坐标是否具有统计学意义(α=0.05)。采用单因素方差分析来分析远端、冠状和颊侧方向的坐标差异与牙齿移动之间是否存在关系(α=0.05):在颊向和冠向,传统印模组和数字印模组之间的差异具有统计学意义。在颊侧方向,Ⅰ度和Ⅱ度活动牙的精确度差异分别为 0.149 毫米和 0.401 毫米。在冠状方向上,分别为 0.128 毫米和 0.233 毫米。同时,方差分析显示,在颊侧和冠侧,点坐标差与牙齿移动性之间存在关系:结论:传统印模会影响活动牙印模的准确性。结论:传统印模会影响活动牙印模的准确性,因此活动牙印模应采用数字印模。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Tooth Mobility on the Accuracy of Conventional Impressions: A Pilot Study.

Purpose: To study the influence of tooth mobility on the accuracy of conventional impressions.

Materials and methods: In total, 10 patients with mobile anterior teeth and 10 healthy patients were treated with conventional impressions and intraoral digital impressions. The digital impression group was recorded as standard data, the mobile teeth group was recorded as the experimental group, and the healthy anterior teeth group was recorded as the control group. We imported digital impression and irreversible hydrocolloid impression files into Geomagic Wrap and marked reference points to execute N-point alignment, then we recorded the coordinates. Paired-samples t test was used to analyze whether the point coordinates of mobile teeth were statistically significant (a = .05). One-way ANOVA was used to analyze whether there was a relationship between coordinate differences and tooth mobility in the distal, coronal, and buccal directions (a = .05).

Results: In the buccal and coronal directions, the difference was statistically significant between the conventional and digital impression groups. In the buccal direction, the accuracy differences of I-degree and II-degree mobile teeth were 0.149 mm and 0.401 mm, respectively. In the coronal direction, the differences were 0.128 mm and 0.233 mm, respectively. Meanwhile, ANOVA analysis showed that there was a relationship between point coordinate difference and tooth mobility in the buccal and coronal directions.

Conclusions: Conventional impressions can influence the accuracy of mobile tooth impressions. Therefore, digital impressions should be adopted for mobile teeth impressions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Digital Workflow for Rehabilitation of Severely Discolored Teeth Due to Red Staining from Endodontic Material. Influence of Different Cements on Bonding Efficiency Between Implant Abutment and Standard Restoration. Thirty-Year Clinical Performance of Double-Crown Retained Removable Partial Dentures - A Practice-Based Retrospective Study. Evaluation of the Bond Strengths Between Dental Ceramics and Co-Cr Frameworks Made with Digital and Conventional Techniques. 3D-Printed Permanent Resin Crowns on Pre-Molar and Molar Teeth; Two-Year Results of a Prospective Clinical Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1