Shyle H Mehta, Timothy G White, Kevin A Shah, Daniel G Lynch, Cassidy D Werner, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo
{"title":"Onyx Frontier™ 和 Resolute Onyx™ 药物洗脱球囊支架用于急性大血管闭塞抢救性支架置入术的单中心疗效。","authors":"Shyle H Mehta, Timothy G White, Kevin A Shah, Daniel G Lynch, Cassidy D Werner, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo","doi":"10.1177/15910199231226285","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In cases where mechanical thrombectomy (MT) fails, rescue stenting may be necessary to achieve reperfusion; however, the lack of standardized techniques or devices poses a challenge. This series aims to present our early experience with the Onyx Frontier™ and Resolute Onyx™ balloon-mounted drug-eluting stents for rescue stenting.</p><p><strong>Methods: </strong>A retrospective chart review was performed of all patients who underwent rescue stenting, in the setting of failed MT, using Onyx Frontier™ or Resolute Onyx™ stents at a single institution. Technical details, procedural complications, and patient outcomes were recorded for each case.</p><p><strong>Results: </strong>Twenty-two Onyx Frontier™ and Resolute Onyx™ stents were deployed in 18 patients undergoing rescue stenting. Stent locations included the middle cerebral artery (36.4%), internal carotid artery (18.2%), vertebral artery (22.7%), and basilar artery (22.7%). The average National Institutes of Health Stroke Scale score before MT was 13.8 (range 0-31). The median initial modified Rankin Scale (mRS) score was zero, while the median mRS score at follow-up was three. Successful reperfusion, as assessed by TICI scores, was achieved in 43.8% of patients for TICI 3, 43.8% for TICI 2C, and 12.5% for TICI 2B. Post-revascularization, 16.7% of patients experienced hemorrhage, of which one patient (5.6%) had symptomatic hemorrhage.</p><p><strong>Conclusions: </strong>Onyx Frontier™ and Resolute Onyx™ stents are well suited for rescue stenting in cases of failed MT. These balloon-mounted drug-eluting stents exhibit excellent navigability, rendering them appropriate for rescue revascularization procedures. Our findings demonstrate that these stents confer a high degree of technical success.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199231226285"},"PeriodicalIF":1.5000,"publicationDate":"2024-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569801/pdf/","citationCount":"0","resultStr":"{\"title\":\"Single-center outcomes of Onyx Frontier™ and Resolute Onyx™ drug-eluting balloon-mounted stents for rescue stenting for acute large vessel occlusion.\",\"authors\":\"Shyle H Mehta, Timothy G White, Kevin A Shah, Daniel G Lynch, Cassidy D Werner, Ina Teron, Thomas Link, Athos Patsalides, Henry H Woo\",\"doi\":\"10.1177/15910199231226285\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In cases where mechanical thrombectomy (MT) fails, rescue stenting may be necessary to achieve reperfusion; however, the lack of standardized techniques or devices poses a challenge. This series aims to present our early experience with the Onyx Frontier™ and Resolute Onyx™ balloon-mounted drug-eluting stents for rescue stenting.</p><p><strong>Methods: </strong>A retrospective chart review was performed of all patients who underwent rescue stenting, in the setting of failed MT, using Onyx Frontier™ or Resolute Onyx™ stents at a single institution. Technical details, procedural complications, and patient outcomes were recorded for each case.</p><p><strong>Results: </strong>Twenty-two Onyx Frontier™ and Resolute Onyx™ stents were deployed in 18 patients undergoing rescue stenting. Stent locations included the middle cerebral artery (36.4%), internal carotid artery (18.2%), vertebral artery (22.7%), and basilar artery (22.7%). The average National Institutes of Health Stroke Scale score before MT was 13.8 (range 0-31). The median initial modified Rankin Scale (mRS) score was zero, while the median mRS score at follow-up was three. Successful reperfusion, as assessed by TICI scores, was achieved in 43.8% of patients for TICI 3, 43.8% for TICI 2C, and 12.5% for TICI 2B. Post-revascularization, 16.7% of patients experienced hemorrhage, of which one patient (5.6%) had symptomatic hemorrhage.</p><p><strong>Conclusions: </strong>Onyx Frontier™ and Resolute Onyx™ stents are well suited for rescue stenting in cases of failed MT. These balloon-mounted drug-eluting stents exhibit excellent navigability, rendering them appropriate for rescue revascularization procedures. Our findings demonstrate that these stents confer a high degree of technical success.</p>\",\"PeriodicalId\":49174,\"journal\":{\"name\":\"Interventional Neuroradiology\",\"volume\":\" \",\"pages\":\"15910199231226285\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-01-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11569801/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Interventional Neuroradiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15910199231226285\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199231226285","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
Single-center outcomes of Onyx Frontier™ and Resolute Onyx™ drug-eluting balloon-mounted stents for rescue stenting for acute large vessel occlusion.
Background: In cases where mechanical thrombectomy (MT) fails, rescue stenting may be necessary to achieve reperfusion; however, the lack of standardized techniques or devices poses a challenge. This series aims to present our early experience with the Onyx Frontier™ and Resolute Onyx™ balloon-mounted drug-eluting stents for rescue stenting.
Methods: A retrospective chart review was performed of all patients who underwent rescue stenting, in the setting of failed MT, using Onyx Frontier™ or Resolute Onyx™ stents at a single institution. Technical details, procedural complications, and patient outcomes were recorded for each case.
Results: Twenty-two Onyx Frontier™ and Resolute Onyx™ stents were deployed in 18 patients undergoing rescue stenting. Stent locations included the middle cerebral artery (36.4%), internal carotid artery (18.2%), vertebral artery (22.7%), and basilar artery (22.7%). The average National Institutes of Health Stroke Scale score before MT was 13.8 (range 0-31). The median initial modified Rankin Scale (mRS) score was zero, while the median mRS score at follow-up was three. Successful reperfusion, as assessed by TICI scores, was achieved in 43.8% of patients for TICI 3, 43.8% for TICI 2C, and 12.5% for TICI 2B. Post-revascularization, 16.7% of patients experienced hemorrhage, of which one patient (5.6%) had symptomatic hemorrhage.
Conclusions: Onyx Frontier™ and Resolute Onyx™ stents are well suited for rescue stenting in cases of failed MT. These balloon-mounted drug-eluting stents exhibit excellent navigability, rendering them appropriate for rescue revascularization procedures. Our findings demonstrate that these stents confer a high degree of technical success.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...