开发一种荧光免疫层析方法,用于定量检测基质金属蛋白酶-9

IF 1.7 Q3 MEDICAL LABORATORY TECHNOLOGY Practical Laboratory Medicine Pub Date : 2024-01-01 DOI:10.1016/j.plabm.2024.e00356
Jingyan Huang , Cuicui Chen , Huankun Liang , Wenqi Dong , Laiqing Li , Hongyan Ma
{"title":"开发一种荧光免疫层析方法,用于定量检测基质金属蛋白酶-9","authors":"Jingyan Huang ,&nbsp;Cuicui Chen ,&nbsp;Huankun Liang ,&nbsp;Wenqi Dong ,&nbsp;Laiqing Li ,&nbsp;Hongyan Ma","doi":"10.1016/j.plabm.2024.e00356","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Abnormal serum matrix metalloproteinase-9 (MMP-9) levels are closely related to the occurrence and development of many diseases. This study aimed to establish a fluorescence immunochromatography (FIC) method using the lanthanide fluorescent element europium(III) (Eu<sup>3+</sup>) for the quantitative measurement of MMP-9 in serum.</p></div><div><h3>Design &amp; Methods</h3><p>The FIC method for quantifying MMP-9 was optimized and established, and the FIC test strips (FICTS) were assembled and subsequently evaluated for sensitivity, specificity and precision. Furthermore, the reference interval and clinical sensitivity/specificity were estimated using clinical healthy/positive serum samples, and a commercial ELISA was used for comparison.</p></div><div><h3>Results</h3><p>We successfully established an FIC method and prepared FICTS. The analytical sensitivity of the FICTS was 0.92 ng/mL, with a linearity range of 0–1000 ng/mL. The cross-reactivity of the 7 common serum interferents was less than 1.56%. All recoveries of the intra-array and inter-array samples ranged from 102.50% to 110.99%, and all <em>CVs</em> were less than 5%. The reference interval of the FICTS was &gt;161.15 ng/mL. The clinical sensitivity was 96.00%, and the specificity was 97.5%. The results of 270 clinical serum samples were highly coincident with the clinical diagnostic results. Pearson correlation analysis and Bland‒Altman plots indicated that the FICTS and commercial ELISA results were consistent with the quantitative MMP-9 concentration.</p></div><div><h3>Conclusions</h3><p>The designed FIC method and test strips may be suitable for point-of-care quantitative measurement of MMP-9, which provides a new method for screening for atherosclerosis, xerophthalmia, etc.</p></div>","PeriodicalId":20421,"journal":{"name":"Practical Laboratory Medicine","volume":"38 ","pages":"Article e00356"},"PeriodicalIF":1.7000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352551724000027/pdfft?md5=283e5035d274edefb4061b80dbdd444a&pid=1-s2.0-S2352551724000027-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Development of a fluorescence immunochromatography method for quantitative measurement of matrix metalloproteinase-9\",\"authors\":\"Jingyan Huang ,&nbsp;Cuicui Chen ,&nbsp;Huankun Liang ,&nbsp;Wenqi Dong ,&nbsp;Laiqing Li ,&nbsp;Hongyan Ma\",\"doi\":\"10.1016/j.plabm.2024.e00356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>Abnormal serum matrix metalloproteinase-9 (MMP-9) levels are closely related to the occurrence and development of many diseases. This study aimed to establish a fluorescence immunochromatography (FIC) method using the lanthanide fluorescent element europium(III) (Eu<sup>3+</sup>) for the quantitative measurement of MMP-9 in serum.</p></div><div><h3>Design &amp; Methods</h3><p>The FIC method for quantifying MMP-9 was optimized and established, and the FIC test strips (FICTS) were assembled and subsequently evaluated for sensitivity, specificity and precision. Furthermore, the reference interval and clinical sensitivity/specificity were estimated using clinical healthy/positive serum samples, and a commercial ELISA was used for comparison.</p></div><div><h3>Results</h3><p>We successfully established an FIC method and prepared FICTS. The analytical sensitivity of the FICTS was 0.92 ng/mL, with a linearity range of 0–1000 ng/mL. The cross-reactivity of the 7 common serum interferents was less than 1.56%. All recoveries of the intra-array and inter-array samples ranged from 102.50% to 110.99%, and all <em>CVs</em> were less than 5%. The reference interval of the FICTS was &gt;161.15 ng/mL. The clinical sensitivity was 96.00%, and the specificity was 97.5%. The results of 270 clinical serum samples were highly coincident with the clinical diagnostic results. Pearson correlation analysis and Bland‒Altman plots indicated that the FICTS and commercial ELISA results were consistent with the quantitative MMP-9 concentration.</p></div><div><h3>Conclusions</h3><p>The designed FIC method and test strips may be suitable for point-of-care quantitative measurement of MMP-9, which provides a new method for screening for atherosclerosis, xerophthalmia, etc.</p></div>\",\"PeriodicalId\":20421,\"journal\":{\"name\":\"Practical Laboratory Medicine\",\"volume\":\"38 \",\"pages\":\"Article e00356\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352551724000027/pdfft?md5=283e5035d274edefb4061b80dbdd444a&pid=1-s2.0-S2352551724000027-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Practical Laboratory Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352551724000027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352551724000027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的血清基质金属蛋白酶-9(MMP-9)水平异常与多种疾病的发生和发展密切相关。本研究旨在建立一种使用镧系荧光元素铕(III)(Eu3+)的荧光免疫层析(FIC)方法,用于定量检测血清中的MMP-9。设计与amp; 方法优化并建立了定量检测MMP-9的FIC方法,并组装了FIC试纸条(FICTS),随后对其灵敏度、特异性和精确度进行了评估。结果我们成功地建立了一种 FIC 方法并制备了 FICTS。FICTS 的分析灵敏度为 0.92 ng/mL,线性范围为 0-1000 ng/mL。7种常见血清干扰物的交叉反应率小于1.56%。所有阵列内和阵列间样品的回收率范围为 102.50% 至 110.99%,所有 CV 均小于 5%。FICTS 的参考区间为 161.15 ng/mL。临床灵敏度为 96.00%,特异性为 97.5%。270 份临床血清样本的结果与临床诊断结果高度吻合。结论 所设计的 FIC 方法和试纸条可能适用于 MMP-9 的床旁定量检测,为动脉粥样硬化、干眼症等疾病的筛查提供了一种新方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of a fluorescence immunochromatography method for quantitative measurement of matrix metalloproteinase-9

Objective

Abnormal serum matrix metalloproteinase-9 (MMP-9) levels are closely related to the occurrence and development of many diseases. This study aimed to establish a fluorescence immunochromatography (FIC) method using the lanthanide fluorescent element europium(III) (Eu3+) for the quantitative measurement of MMP-9 in serum.

Design & Methods

The FIC method for quantifying MMP-9 was optimized and established, and the FIC test strips (FICTS) were assembled and subsequently evaluated for sensitivity, specificity and precision. Furthermore, the reference interval and clinical sensitivity/specificity were estimated using clinical healthy/positive serum samples, and a commercial ELISA was used for comparison.

Results

We successfully established an FIC method and prepared FICTS. The analytical sensitivity of the FICTS was 0.92 ng/mL, with a linearity range of 0–1000 ng/mL. The cross-reactivity of the 7 common serum interferents was less than 1.56%. All recoveries of the intra-array and inter-array samples ranged from 102.50% to 110.99%, and all CVs were less than 5%. The reference interval of the FICTS was >161.15 ng/mL. The clinical sensitivity was 96.00%, and the specificity was 97.5%. The results of 270 clinical serum samples were highly coincident with the clinical diagnostic results. Pearson correlation analysis and Bland‒Altman plots indicated that the FICTS and commercial ELISA results were consistent with the quantitative MMP-9 concentration.

Conclusions

The designed FIC method and test strips may be suitable for point-of-care quantitative measurement of MMP-9, which provides a new method for screening for atherosclerosis, xerophthalmia, etc.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Practical Laboratory Medicine
Practical Laboratory Medicine Health Professions-Radiological and Ultrasound Technology
CiteScore
3.50
自引率
0.00%
发文量
40
审稿时长
7 weeks
期刊介绍: Practical Laboratory Medicine is a high-quality, peer-reviewed, international open-access journal publishing original research, new methods and critical evaluations, case reports and short papers in the fields of clinical chemistry and laboratory medicine. The objective of the journal is to provide practical information of immediate relevance to workers in clinical laboratories. The primary scope of the journal covers clinical chemistry, hematology, molecular biology and genetics relevant to laboratory medicine, microbiology, immunology, therapeutic drug monitoring and toxicology, laboratory management and informatics. We welcome papers which describe critical evaluations of biomarkers and their role in the diagnosis and treatment of clinically significant disease, validation of commercial and in-house IVD methods, method comparisons, interference reports, the development of new reagents and reference materials, reference range studies and regulatory compliance reports. Manuscripts describing the development of new methods applicable to laboratory medicine (including point-of-care testing) are particularly encouraged, even if preliminary or small scale.
期刊最新文献
Development of a rapid LFA test based on direct RT-LAMP for diagnosis of SARS-CoV-2 The measurement of immunosuppressive drugs by mass spectrometry and immunoassay in a South African transplant setting Falsely abnormal serum protein electrophoresis after administration of intravenous immunoglobulins (IVIG): A retrospective cohort study Glycated albumin in pregnancy correlates negatively with body mass index and contributes to the risk of gestational diabetes mellitus A novel case of Hb Bart's hydrops fetalis following prenatal diagnosis: Case report from Huizhou, China
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1