带环空间维持器的手臂设计影响其使用寿命:一项针对患者的有限元研究。

IF 1.5 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Clinical Pediatric Dentistry Pub Date : 2024-01-01 Epub Date: 2024-01-03 DOI:10.22514/jocpd.2024.019
Özgür Doğan, Suat Serhan Altıntepe Doğan
{"title":"带环空间维持器的手臂设计影响其使用寿命:一项针对患者的有限元研究。","authors":"Özgür Doğan, Suat Serhan Altıntepe Doğan","doi":"10.22514/jocpd.2024.019","DOIUrl":null,"url":null,"abstract":"<p><p>Fixed space maintainers (FSMs) are commonly utilized in pediatric dentistry to prevent space loss following premature tooth extraction. Although previous studies have examined the survival rates and causes of FSM failure, the impact of arm design on failure has not been investigated. This study aimed to investigate the tensile and compressive stresses related to FSMs with different arm designs and evaluate the effect of arm designs on FSM failure. Cone beam computed tomography images of a child who experienced premature loss of a primary mandibular left second molar tooth were retrieved from our database, then processed and simulated using the Rhinoceros software. Finite element analysis was performed to evaluate the stresses on four distinct FSM arm designs under simulated chewing forces. The results showed that the straight-arm FSM design exhibited the highest von Mises principal stress, while FSMs with curved arms and surrounding primary mandibular left first molar in the mesial area demonstrated the lowest von Mises stress accumulation. Intense stress accumulation on the distal surface of tooth 74 was observed in the test models due to the transmitted forces by the FSM. The maximum principal stresses accumulated at the base of the alveolar socket of the mesial root of tooth 36, while the minimum principal stresses were identified at the mesio-marginal area of the alveolar crest. The arm design played a crucial role in enabling the appliance to effectively withstand the stresses accumulating on the Space maintainer (SM) and orthodontic band. Bending the SM arms to match the surrounding profile with curvature increased the stress absorption capacity by increasing the arm length.</p>","PeriodicalId":50235,"journal":{"name":"Journal of Clinical Pediatric Dentistry","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Arm design of band and loop space maintainer affects its longevity: a patient-specific finite element study.\",\"authors\":\"Özgür Doğan, Suat Serhan Altıntepe Doğan\",\"doi\":\"10.22514/jocpd.2024.019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fixed space maintainers (FSMs) are commonly utilized in pediatric dentistry to prevent space loss following premature tooth extraction. Although previous studies have examined the survival rates and causes of FSM failure, the impact of arm design on failure has not been investigated. This study aimed to investigate the tensile and compressive stresses related to FSMs with different arm designs and evaluate the effect of arm designs on FSM failure. Cone beam computed tomography images of a child who experienced premature loss of a primary mandibular left second molar tooth were retrieved from our database, then processed and simulated using the Rhinoceros software. Finite element analysis was performed to evaluate the stresses on four distinct FSM arm designs under simulated chewing forces. The results showed that the straight-arm FSM design exhibited the highest von Mises principal stress, while FSMs with curved arms and surrounding primary mandibular left first molar in the mesial area demonstrated the lowest von Mises stress accumulation. Intense stress accumulation on the distal surface of tooth 74 was observed in the test models due to the transmitted forces by the FSM. The maximum principal stresses accumulated at the base of the alveolar socket of the mesial root of tooth 36, while the minimum principal stresses were identified at the mesio-marginal area of the alveolar crest. The arm design played a crucial role in enabling the appliance to effectively withstand the stresses accumulating on the Space maintainer (SM) and orthodontic band. Bending the SM arms to match the surrounding profile with curvature increased the stress absorption capacity by increasing the arm length.</p>\",\"PeriodicalId\":50235,\"journal\":{\"name\":\"Journal of Clinical Pediatric Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Pediatric Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.22514/jocpd.2024.019\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Pediatric Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22514/jocpd.2024.019","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

固定间隙保持器(FSM)通常用于儿童牙科,以防止过早拔牙后的间隙丧失。尽管之前的研究已经对 FSM 的存活率和失效原因进行了研究,但尚未调查臂设计对失效的影响。本研究旨在调查与不同臂设计的 FSM 相关的拉伸和压缩应力,并评估臂设计对 FSM 失效的影响。我们从数据库中检索了一名下颌左侧第二磨牙早失儿童的锥形束计算机断层扫描图像,然后使用 Rhinoceros 软件进行了处理和模拟。在模拟咀嚼力的作用下,对四种不同的 FSM 支臂设计进行了应力评估的有限元分析。结果显示,直臂式 FSM 设计显示出最高的 von Mises 主应力,而弯曲臂式 FSM 和围绕下颌左侧第一磨牙中轴区域的 FSM 显示出最低的 von Mises 应力累积。由于 FSM 传递的力,在测试模型中观察到第 74 号牙齿远端表面有强烈的应力累积。最大主应力累积在 36 号牙齿中侧根的牙槽基底,而最小主应力则出现在牙槽嵴的中缘区域。矫治臂的设计在使矫治器有效承受空间维持器(SM)和正畸带累积的应力方面起着至关重要的作用。通过增加矫治臂的长度,弯曲矫治臂使其与周围轮廓的弧度相匹配,从而提高了应力吸收能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Arm design of band and loop space maintainer affects its longevity: a patient-specific finite element study.

Fixed space maintainers (FSMs) are commonly utilized in pediatric dentistry to prevent space loss following premature tooth extraction. Although previous studies have examined the survival rates and causes of FSM failure, the impact of arm design on failure has not been investigated. This study aimed to investigate the tensile and compressive stresses related to FSMs with different arm designs and evaluate the effect of arm designs on FSM failure. Cone beam computed tomography images of a child who experienced premature loss of a primary mandibular left second molar tooth were retrieved from our database, then processed and simulated using the Rhinoceros software. Finite element analysis was performed to evaluate the stresses on four distinct FSM arm designs under simulated chewing forces. The results showed that the straight-arm FSM design exhibited the highest von Mises principal stress, while FSMs with curved arms and surrounding primary mandibular left first molar in the mesial area demonstrated the lowest von Mises stress accumulation. Intense stress accumulation on the distal surface of tooth 74 was observed in the test models due to the transmitted forces by the FSM. The maximum principal stresses accumulated at the base of the alveolar socket of the mesial root of tooth 36, while the minimum principal stresses were identified at the mesio-marginal area of the alveolar crest. The arm design played a crucial role in enabling the appliance to effectively withstand the stresses accumulating on the Space maintainer (SM) and orthodontic band. Bending the SM arms to match the surrounding profile with curvature increased the stress absorption capacity by increasing the arm length.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Pediatric Dentistry
Journal of Clinical Pediatric Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-PEDIATRICS
CiteScore
1.80
自引率
7.70%
发文量
47
期刊介绍: The purpose of The Journal of Clinical Pediatric Dentistry is to provide clinically relevant information to enable the practicing dentist to have access to the state of the art in pediatric dentistry. From prevention, to information, to the management of different problems encountered in children''s related medical and dental problems, this peer-reviewed journal keeps you abreast of the latest news and developments related to pediatric dentistry.
期刊最新文献
Segmental root development of immature necrotic permanent teeth following regenerative endodontic procedures: a case series. Sleep bruxism in children main methods of treatment: a systematic review with meta-analysis. Temporal variation in the oral microbiome and the prediction of early childhood caries in different ethnicities. The impact of clinical audit on antibiotic prescribing in dental practice at Taibah University Dental Hospital. A severely damaged premolar tooth restored with coronal pulpotomy and a 3D-printed endocrown.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1