{"title":"心脏植入式电子设备患者的围手术期管理。","authors":"Minsu Kim, Chang Hee Kwon","doi":"10.4097/kja.23826","DOIUrl":null,"url":null,"abstract":"<p><p>The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.</p>","PeriodicalId":17855,"journal":{"name":"Korean Journal of Anesthesiology","volume":null,"pages":null},"PeriodicalIF":4.2000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11150116/pdf/","citationCount":"0","resultStr":"{\"title\":\"Perioperative management of patients with cardiac implantable electronic devices.\",\"authors\":\"Minsu Kim, Chang Hee Kwon\",\"doi\":\"10.4097/kja.23826\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.</p>\",\"PeriodicalId\":17855,\"journal\":{\"name\":\"Korean Journal of Anesthesiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11150116/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Anesthesiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4097/kja.23826\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4097/kja.23826","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
Perioperative management of patients with cardiac implantable electronic devices.
The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.