{"title":"基于人体眼底图像的青光眼诊断方法","authors":"S. V. Komkova","doi":"10.21869/2223-1536-2023-13-4-99-114","DOIUrl":null,"url":null,"abstract":"The purpose of the research to develop a technique for detecting glaucoma, which is based on calculating the size ratio of the optical cup and optical disc and the \"four quadrants\" rule. Their use increases the accuracy of glaucoma detection in human retina images.Methods. A glaucoma detection technique is proposed that uses the ratio of the vertical diameter of the cup to the vertical diameter of the disc and the \"four quadrants\" rule as the two main parameters for the detection of glaucoma. The optic nerve disc (OD), the ocular cup (OCH) are segmented using the area extension method and the watershed method, and then combined to obtain the final results. Their union is performed using the logical operation OR. The resulting images are approximated using circular approximation, since its implementation is simple by calculating a single center and radius. For diagnostics, it was decided to use two parameters: the ratio of the cup and the disc (OCD) and the rule of \"four quadrants\". Their combined assessment makes it possible to increase the accuracy of glaucoma detection.Results: the study of the proposed technique was performed on retinal images obtained from 4 databases: HRF, DIARETDB1, DRIONS-DB, Messidor. The study showed that the proposed technique correctly identifies 75 retinal images as glaucoma out of 84 with a total sensitivity of 91.67%. Of the 163 normal images, 154 were correctly classified as normal with a specificity of 94.47%.Conclusion. The proposed method is simple and computationally efficient. It can be effectively used in computer diagnostics of glaucoma in the early stages of the disease.","PeriodicalId":166124,"journal":{"name":"Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering","volume":"32 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Method of Diagnosis of Glaucoma Based on Human Fundus Images\",\"authors\":\"S. V. Komkova\",\"doi\":\"10.21869/2223-1536-2023-13-4-99-114\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The purpose of the research to develop a technique for detecting glaucoma, which is based on calculating the size ratio of the optical cup and optical disc and the \\\"four quadrants\\\" rule. Their use increases the accuracy of glaucoma detection in human retina images.Methods. A glaucoma detection technique is proposed that uses the ratio of the vertical diameter of the cup to the vertical diameter of the disc and the \\\"four quadrants\\\" rule as the two main parameters for the detection of glaucoma. The optic nerve disc (OD), the ocular cup (OCH) are segmented using the area extension method and the watershed method, and then combined to obtain the final results. Their union is performed using the logical operation OR. The resulting images are approximated using circular approximation, since its implementation is simple by calculating a single center and radius. For diagnostics, it was decided to use two parameters: the ratio of the cup and the disc (OCD) and the rule of \\\"four quadrants\\\". Their combined assessment makes it possible to increase the accuracy of glaucoma detection.Results: the study of the proposed technique was performed on retinal images obtained from 4 databases: HRF, DIARETDB1, DRIONS-DB, Messidor. The study showed that the proposed technique correctly identifies 75 retinal images as glaucoma out of 84 with a total sensitivity of 91.67%. Of the 163 normal images, 154 were correctly classified as normal with a specificity of 94.47%.Conclusion. The proposed method is simple and computationally efficient. It can be effectively used in computer diagnostics of glaucoma in the early stages of the disease.\",\"PeriodicalId\":166124,\"journal\":{\"name\":\"Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering\",\"volume\":\"32 22\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21869/2223-1536-2023-13-4-99-114\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21869/2223-1536-2023-13-4-99-114","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究的目的是开发一种检测青光眼的技术,该技术基于计算光学杯和光学盘的尺寸比以及 "四象限 "规则。它们的使用提高了人类视网膜图像中青光眼检测的准确性。本研究提出了一种青光眼检测技术,该技术以光杯垂直直径与光盘垂直直径之比以及 "四象限 "法则作为检测青光眼的两个主要参数。使用面积扩展法和分水岭法对视神经盘(OD)和眼杯(OCH)进行分割,然后将其合并以获得最终结果。它们的合并使用逻辑运算 OR 进行。生成的图像使用圆形近似法进行近似,因为只需计算一个中心和半径即可简单实现。在诊断方面,决定使用两个参数:杯和盘的比率(OCD)和 "四象限 "规则。结果:对从 4 个数据库中获得的视网膜图像进行了研究:HRF、DIARETDB1、DRIONS-DB 和 Messidor。研究表明,在 84 幅视网膜图像中,所提出的技术能正确识别出 75 幅为青光眼图像,总灵敏度为 91.67%。在 163 张正常图像中,154 张被正确分类为正常,特异性为 94.47%。所提出的方法简单,计算效率高。它可有效地用于青光眼早期阶段的计算机诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Method of Diagnosis of Glaucoma Based on Human Fundus Images
The purpose of the research to develop a technique for detecting glaucoma, which is based on calculating the size ratio of the optical cup and optical disc and the "four quadrants" rule. Their use increases the accuracy of glaucoma detection in human retina images.Methods. A glaucoma detection technique is proposed that uses the ratio of the vertical diameter of the cup to the vertical diameter of the disc and the "four quadrants" rule as the two main parameters for the detection of glaucoma. The optic nerve disc (OD), the ocular cup (OCH) are segmented using the area extension method and the watershed method, and then combined to obtain the final results. Their union is performed using the logical operation OR. The resulting images are approximated using circular approximation, since its implementation is simple by calculating a single center and radius. For diagnostics, it was decided to use two parameters: the ratio of the cup and the disc (OCD) and the rule of "four quadrants". Their combined assessment makes it possible to increase the accuracy of glaucoma detection.Results: the study of the proposed technique was performed on retinal images obtained from 4 databases: HRF, DIARETDB1, DRIONS-DB, Messidor. The study showed that the proposed technique correctly identifies 75 retinal images as glaucoma out of 84 with a total sensitivity of 91.67%. Of the 163 normal images, 154 were correctly classified as normal with a specificity of 94.47%.Conclusion. The proposed method is simple and computationally efficient. It can be effectively used in computer diagnostics of glaucoma in the early stages of the disease.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Computer Аssessment of the Risk of Нerniated Protrusions of the lntervertebral Discs of the Neck Based on MRl Data Model of a Prototype Expert System for the Formation of a Simple Classifier of Competencies Automated Classification of Abdominal Ultrasound lmages of the Pancreas Based on the Spectral Representation of the Border’s Contours Accounting and Monitoring System of Electricity Expenditures Based on Geospatient Data Consumers Location Analytical Modeling of Breast Elastography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1