{"title":"放射防护案例中的牙科 X 射线辐照和牙科图像重复性因素","authors":"Asmiati Amir, Muhammad Yunus, Septiana Kurniasari, C. Payu","doi":"10.29100/.v6i1.5123","DOIUrl":null,"url":null,"abstract":"This research was carried out using a literature review method to determine radioprotection cases and repeatability factors of dental images on dental X-rays. Determination of the repeatability factor for dental photographs using data over three months obtained at Rajawali Citra Hospital, RSUD Dr. Tjitrowardojo Purworejo, and RSUD Muntilan Magelang. Case A, case B, and case C produce high percentage values. This is because dental practitioners consider the provision of protection in reducing the scattered dose of dental X-rays for patients to be often overlooked. Determination of X-ray radiation exposure given by a radiographer does not have significant differences for each patient, such as thin, standard, and obese. Meanwhile, the data on the percentage value of repetition of dental images exceeds the Minimum Hospital Service Standard indicator limit by the Decree of the Minister of Health Number 129 of 2008 concerning the incidence of X-ray service failure, which has a photo failure standard of ≤ 2%. The highest position factor was obtained at Hospital-2 at 75%, and the lowest was obtained at Hospital-1 at 50%. Meanwhile, the highest exposure factor was obtained at Hospital-1 at 39% and the weakest at Hospital-2 at 25%. Position errors made by the radiographer cause position factors, and exposure errors are caused by exposure factors that are too high or low.","PeriodicalId":399125,"journal":{"name":"EDUPROXIMA : Jurnal Ilmiah Pendidikan IPA","volume":"24 S52","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"DENTAL X-RAY RADIATION EXPOSURE IN RADIOPROTECTION CASES AND DENTAL IMAGES REPEATABILITY FACTORS\",\"authors\":\"Asmiati Amir, Muhammad Yunus, Septiana Kurniasari, C. Payu\",\"doi\":\"10.29100/.v6i1.5123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research was carried out using a literature review method to determine radioprotection cases and repeatability factors of dental images on dental X-rays. Determination of the repeatability factor for dental photographs using data over three months obtained at Rajawali Citra Hospital, RSUD Dr. Tjitrowardojo Purworejo, and RSUD Muntilan Magelang. Case A, case B, and case C produce high percentage values. This is because dental practitioners consider the provision of protection in reducing the scattered dose of dental X-rays for patients to be often overlooked. Determination of X-ray radiation exposure given by a radiographer does not have significant differences for each patient, such as thin, standard, and obese. Meanwhile, the data on the percentage value of repetition of dental images exceeds the Minimum Hospital Service Standard indicator limit by the Decree of the Minister of Health Number 129 of 2008 concerning the incidence of X-ray service failure, which has a photo failure standard of ≤ 2%. The highest position factor was obtained at Hospital-2 at 75%, and the lowest was obtained at Hospital-1 at 50%. Meanwhile, the highest exposure factor was obtained at Hospital-1 at 39% and the weakest at Hospital-2 at 25%. Position errors made by the radiographer cause position factors, and exposure errors are caused by exposure factors that are too high or low.\",\"PeriodicalId\":399125,\"journal\":{\"name\":\"EDUPROXIMA : Jurnal Ilmiah Pendidikan IPA\",\"volume\":\"24 S52\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EDUPROXIMA : Jurnal Ilmiah Pendidikan IPA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29100/.v6i1.5123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EDUPROXIMA : Jurnal Ilmiah Pendidikan IPA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29100/.v6i1.5123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
本研究采用文献综述法来确定牙科 X 射线图像的放射防护案例和可重复性系数。利用在 Rajawali Citra 医院、RSUD Dr. Tjitrowardojo Purworejo 和 RSUD Muntilan Magelang 获得的三个月的数据,确定牙科照片的重复性系数。病例 A、病例 B 和病例 C 的百分比值较高。这是因为牙科医生认为,为患者提供保护以减少牙科 X 射线的散射剂量往往被忽视。放射技师对每个病人的 X 射线辐射量的测定,如瘦弱、标准和肥胖,并无明显差异。同时,牙科图像重复率的数据超过了卫生部 2008 年第 129 号法令规定的医院最低服务标准指标,即 X 射线服务故障发生率,其照片故障标准为 ≤ 2%。位置系数最高的是医院 2,为 75%,最低的是医院 1,为 50%。同时,曝光系数最高的是医院 1,为 39%,最低的是医院 2,为 25%。放射技师的位置误差会导致位置系数,而曝光系数过高或过低则会导致曝光误差。
DENTAL X-RAY RADIATION EXPOSURE IN RADIOPROTECTION CASES AND DENTAL IMAGES REPEATABILITY FACTORS
This research was carried out using a literature review method to determine radioprotection cases and repeatability factors of dental images on dental X-rays. Determination of the repeatability factor for dental photographs using data over three months obtained at Rajawali Citra Hospital, RSUD Dr. Tjitrowardojo Purworejo, and RSUD Muntilan Magelang. Case A, case B, and case C produce high percentage values. This is because dental practitioners consider the provision of protection in reducing the scattered dose of dental X-rays for patients to be often overlooked. Determination of X-ray radiation exposure given by a radiographer does not have significant differences for each patient, such as thin, standard, and obese. Meanwhile, the data on the percentage value of repetition of dental images exceeds the Minimum Hospital Service Standard indicator limit by the Decree of the Minister of Health Number 129 of 2008 concerning the incidence of X-ray service failure, which has a photo failure standard of ≤ 2%. The highest position factor was obtained at Hospital-2 at 75%, and the lowest was obtained at Hospital-1 at 50%. Meanwhile, the highest exposure factor was obtained at Hospital-1 at 39% and the weakest at Hospital-2 at 25%. Position errors made by the radiographer cause position factors, and exposure errors are caused by exposure factors that are too high or low.