Nana Louise Christensen, Jens Sørensen, Kirsten Bouchelouche, Michael Alle Madsen, Christian Selmer Buhl, Lars Poulsen Tolbod
{"title":"用于下肢骨骼肌灌注的[15O]H2O PET 成像的重复性:一项重复测试研究。","authors":"Nana Louise Christensen, Jens Sørensen, Kirsten Bouchelouche, Michael Alle Madsen, Christian Selmer Buhl, Lars Poulsen Tolbod","doi":"10.1186/s13550-024-01073-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>[<sup>15</sup>O]H<sub>2</sub>O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [<sup>15</sup>O]H<sub>2</sub>O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [<sup>15</sup>O]H<sub>2</sub>O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K<sub>1</sub> values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans.</p><p><strong>Results: </strong>Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98).</p><p><strong>Conclusion: </strong>Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.</p>","PeriodicalId":11611,"journal":{"name":"EJNMMI Research","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10830956/pdf/","citationCount":"0","resultStr":"{\"title\":\"Repeatability of [<sup>15</sup>O]H<sub>2</sub>O PET imaging for lower extremity skeletal muscle perfusion: a test-retest study.\",\"authors\":\"Nana Louise Christensen, Jens Sørensen, Kirsten Bouchelouche, Michael Alle Madsen, Christian Selmer Buhl, Lars Poulsen Tolbod\",\"doi\":\"10.1186/s13550-024-01073-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>[<sup>15</sup>O]H<sub>2</sub>O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [<sup>15</sup>O]H<sub>2</sub>O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [<sup>15</sup>O]H<sub>2</sub>O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K<sub>1</sub> values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans.</p><p><strong>Results: </strong>Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98).</p><p><strong>Conclusion: </strong>Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.</p>\",\"PeriodicalId\":11611,\"journal\":{\"name\":\"EJNMMI Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10830956/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"EJNMMI Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s13550-024-01073-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13550-024-01073-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test-retest study.
Background: [15O]H2O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [15O]H2O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [15O]H2O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K1 values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans.
Results: Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98).
Conclusion: Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.
EJNMMI ResearchRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING&nb-
CiteScore
5.90
自引率
3.10%
发文量
72
审稿时长
13 weeks
期刊介绍:
EJNMMI Research publishes new basic, translational and clinical research in the field of nuclear medicine and molecular imaging. Regular features include original research articles, rapid communication of preliminary data on innovative research, interesting case reports, editorials, and letters to the editor. Educational articles on basic sciences, fundamental aspects and controversy related to pre-clinical and clinical research or ethical aspects of research are also welcome. Timely reviews provide updates on current applications, issues in imaging research and translational aspects of nuclear medicine and molecular imaging technologies.
The main emphasis is placed on the development of targeted imaging with radiopharmaceuticals within the broader context of molecular probes to enhance understanding and characterisation of the complex biological processes underlying disease and to develop, test and guide new treatment modalities, including radionuclide therapy.