新型经心尖腱膜植入系统在猪模型中的可行性研究

IF 1.2 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS International heart journal Pub Date : 2024-01-31 DOI:10.1536/ihj.23-206
Yuntao Lu, Jinmiao Chen, Minyan Yin, Ye Yang, Wenshuo Wang, Lili Dong, Wenyu Song, Jian Meng, Qingliang Zhou, Lai Wei
{"title":"新型经心尖腱膜植入系统在猪模型中的可行性研究","authors":"Yuntao Lu, Jinmiao Chen, Minyan Yin, Ye Yang, Wenshuo Wang, Lili Dong, Wenyu Song, Jian Meng, Qingliang Zhou, Lai Wei","doi":"10.1536/ihj.23-206","DOIUrl":null,"url":null,"abstract":"</p><p>Transapical beating-heart mitral repair with chordal implantation system has been considered as an alternative treatment for degenerative mitral regurgitation. This study aimed to assess the feasibility and safety of the E-Chord system (Med-Zenith Medical, Beijing, China) for transapical beating-heart mitral valve repair in a porcine model. Artificial chordae were transapically implanted on the mitral valves of 12 anesthetized pigs under epicardial echocardiographic guidance and secured outside the left ventricular apex. The study endpoints included procedural success, device durability, and tissue response to the device. The procedural success rate was 100% (12/12). All animals were implanted with E-Chord in the anterior and posterior leaflets, respectively, and survived uneventfully until euthanized as planned. During the 180-day follow-up, no animal had significant mitral valve dysfunction. The gross observation showed no evidence of anchor detachment and chordal rupture, and there was no obvious damage or changes to mitral leaflets. Microscopic evaluation revealed that the endothelialization of anchor and chordae was completed 90 days after implantation and there was no evidence of chordal rupture, thrombosis, or infection during the 180-day follow-up. The E-Chord system was found to be feasible and safe for heart-beating mitral chordal implantation in a porcine model. The findings of this study suggest that the E-Chord system may be a potential alternative for the treatment of degenerative mitral regurgitation in humans.</p>\n<p></p>","PeriodicalId":13711,"journal":{"name":"International heart journal","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Feasibility Study of a Novel Transapical Chordal Implantation System in a Porcine Model\",\"authors\":\"Yuntao Lu, Jinmiao Chen, Minyan Yin, Ye Yang, Wenshuo Wang, Lili Dong, Wenyu Song, Jian Meng, Qingliang Zhou, Lai Wei\",\"doi\":\"10.1536/ihj.23-206\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"</p><p>Transapical beating-heart mitral repair with chordal implantation system has been considered as an alternative treatment for degenerative mitral regurgitation. This study aimed to assess the feasibility and safety of the E-Chord system (Med-Zenith Medical, Beijing, China) for transapical beating-heart mitral valve repair in a porcine model. Artificial chordae were transapically implanted on the mitral valves of 12 anesthetized pigs under epicardial echocardiographic guidance and secured outside the left ventricular apex. The study endpoints included procedural success, device durability, and tissue response to the device. The procedural success rate was 100% (12/12). All animals were implanted with E-Chord in the anterior and posterior leaflets, respectively, and survived uneventfully until euthanized as planned. During the 180-day follow-up, no animal had significant mitral valve dysfunction. The gross observation showed no evidence of anchor detachment and chordal rupture, and there was no obvious damage or changes to mitral leaflets. Microscopic evaluation revealed that the endothelialization of anchor and chordae was completed 90 days after implantation and there was no evidence of chordal rupture, thrombosis, or infection during the 180-day follow-up. The E-Chord system was found to be feasible and safe for heart-beating mitral chordal implantation in a porcine model. The findings of this study suggest that the E-Chord system may be a potential alternative for the treatment of degenerative mitral regurgitation in humans.</p>\\n<p></p>\",\"PeriodicalId\":13711,\"journal\":{\"name\":\"International heart journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International heart journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1536/ihj.23-206\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International heart journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1536/ihj.23-206","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

经心尖搏动二尖瓣修复术与弦膜植入系统被认为是退行性二尖瓣反流的替代治疗方法。本研究旨在评估 E-Chord 系统(Med-Zenith Medical,中国北京)在猪模型中用于经心尖搏动二尖瓣修复的可行性和安全性。在心外膜超声心动图引导下,将人工腱索经心尖植入12头麻醉猪的二尖瓣,并固定在左心室心尖外。研究终点包括手术成功率、装置耐用性和组织对装置的反应。手术成功率为 100%(12/12)。所有动物都分别在前叶和后叶植入了 E-Chord,并顺利存活至按计划安乐死。在 180 天的随访期间,没有动物出现明显的二尖瓣功能障碍。大体观察显示没有锚脱落和弦断裂的迹象,二尖瓣叶也没有明显的损伤或变化。显微镜评估显示,锚和腱索的内皮化在植入后 90 天完成,180 天的随访期间没有发现腱索断裂、血栓形成或感染的迹象。研究发现,E-Chord 系统在猪模型中用于心脏跳动的二尖瓣腱索植入是可行和安全的。这项研究结果表明,E-Chord 系统可能是治疗人类退行性二尖瓣反流的一种潜在替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility Study of a Novel Transapical Chordal Implantation System in a Porcine Model

Transapical beating-heart mitral repair with chordal implantation system has been considered as an alternative treatment for degenerative mitral regurgitation. This study aimed to assess the feasibility and safety of the E-Chord system (Med-Zenith Medical, Beijing, China) for transapical beating-heart mitral valve repair in a porcine model. Artificial chordae were transapically implanted on the mitral valves of 12 anesthetized pigs under epicardial echocardiographic guidance and secured outside the left ventricular apex. The study endpoints included procedural success, device durability, and tissue response to the device. The procedural success rate was 100% (12/12). All animals were implanted with E-Chord in the anterior and posterior leaflets, respectively, and survived uneventfully until euthanized as planned. During the 180-day follow-up, no animal had significant mitral valve dysfunction. The gross observation showed no evidence of anchor detachment and chordal rupture, and there was no obvious damage or changes to mitral leaflets. Microscopic evaluation revealed that the endothelialization of anchor and chordae was completed 90 days after implantation and there was no evidence of chordal rupture, thrombosis, or infection during the 180-day follow-up. The E-Chord system was found to be feasible and safe for heart-beating mitral chordal implantation in a porcine model. The findings of this study suggest that the E-Chord system may be a potential alternative for the treatment of degenerative mitral regurgitation in humans.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International heart journal
International heart journal 医学-心血管系统
CiteScore
2.50
自引率
6.70%
发文量
148
审稿时长
6-12 weeks
期刊介绍: Authors of research articles should disclose at the time of submission any financial arrangement they may have with a company whose product figures prominently in the submitted manuscript or with a company making a competing product. Such information will be held in confidence while the paper is under review and will not influence the editorial decision, but if the article is accepted for publication, the editors will usually discuss with the authors the manner in which such information is to be communicated to the reader.
期刊最新文献
Animal Experimental Study of Bioabsorbable Left Atrial Appendage Occluder Colchicine Prevents Cardiac Rupture in Mice with Myocardial Infarction by Inhibiting P53-Dependent Apoptosis Identification of the Neointimal Hyperplasia-Related LncRNA-mRNA-Immune Cell Regulatory Network in a Rat Carotid Artery Balloon Injury Model A Case of Aortopulmonary Fistula with Post-Operative Aortic Pseudoaneurysm Diagnosed by Transesophageal Echocardiography Different Impact of Immunosuppressive Therapy on Cardiac Outcomes in Systemic Versus Isolated Cardiac Sarcoidosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1