Antoine Elias, Tobias Weber, David A Green, Katie M Harris, Jonathan M Laws, Danielle K Greaves, David S Kim, Lucia Mazzolai-Duchosal, Lara Roberts, Lonnie G Petersen, Ulrich Limper, Andrej Bergauer, Michael Elias, Andrew Winnard, Nandu Goswami
{"title":"关于在太空飞行中使用超声波进行静脉评估和静脉血栓筛查的系统性综述。","authors":"Antoine Elias, Tobias Weber, David A Green, Katie M Harris, Jonathan M Laws, Danielle K Greaves, David S Kim, Lucia Mazzolai-Duchosal, Lara Roberts, Lonnie G Petersen, Ulrich Limper, Andrej Bergauer, Michael Elias, Andrew Winnard, Nandu Goswami","doi":"10.1038/s41526-024-00356-w","DOIUrl":null,"url":null,"abstract":"<p><p>The validity of venous ultrasound (V-US) for the diagnosis of deep vein thrombosis (DVT) during spaceflight is unknown and difficult to establish in diagnostic accuracy and diagnostic management studies in this context. We performed a systematic review of the use of V-US in the upper-body venous system in spaceflight to identify microgravity-related changes and the effect of venous interventions to reverse them, and to assess appropriateness of spaceflight V-US with terrestrial standards. An appropriateness tool was developed following expert panel discussions and review of terrestrial diagnostic studies, including criteria relevant to crew experience, in-flight equipment, assessment sites, ultrasound modalities, and DVT diagnosis. Microgravity-related findings reported as an increase in internal jugular vein (IJV) cross-sectional area and pressure were associated with reduced, stagnant, and retrograde flow. Changes were on average responsive to venous interventions using lower body negative pressure, Bracelets, Valsalva and Mueller manoeuvres, and contralateral IJV compression. In comparison with terrestrial standards, spaceflight V-US did not meet all appropriateness criteria. In DVT studies (n = 3), a single thrombosis was reported and only ultrasound modality criterion met the standards. In the other studies (n = 15), all the criteria were appropriate except crew experience criterion, which was appropriate in only four studies. Future practice and research should account for microgravity-related changes, evaluate individual effect of venous interventions, and adopt Earth-based V-US standards.</p>","PeriodicalId":54263,"journal":{"name":"npj Microgravity","volume":null,"pages":null},"PeriodicalIF":4.4000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10844233/pdf/","citationCount":"0","resultStr":"{\"title\":\"Systematic review of the use of ultrasound for venous assessment and venous thrombosis screening in spaceflight.\",\"authors\":\"Antoine Elias, Tobias Weber, David A Green, Katie M Harris, Jonathan M Laws, Danielle K Greaves, David S Kim, Lucia Mazzolai-Duchosal, Lara Roberts, Lonnie G Petersen, Ulrich Limper, Andrej Bergauer, Michael Elias, Andrew Winnard, Nandu Goswami\",\"doi\":\"10.1038/s41526-024-00356-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The validity of venous ultrasound (V-US) for the diagnosis of deep vein thrombosis (DVT) during spaceflight is unknown and difficult to establish in diagnostic accuracy and diagnostic management studies in this context. We performed a systematic review of the use of V-US in the upper-body venous system in spaceflight to identify microgravity-related changes and the effect of venous interventions to reverse them, and to assess appropriateness of spaceflight V-US with terrestrial standards. An appropriateness tool was developed following expert panel discussions and review of terrestrial diagnostic studies, including criteria relevant to crew experience, in-flight equipment, assessment sites, ultrasound modalities, and DVT diagnosis. Microgravity-related findings reported as an increase in internal jugular vein (IJV) cross-sectional area and pressure were associated with reduced, stagnant, and retrograde flow. Changes were on average responsive to venous interventions using lower body negative pressure, Bracelets, Valsalva and Mueller manoeuvres, and contralateral IJV compression. In comparison with terrestrial standards, spaceflight V-US did not meet all appropriateness criteria. In DVT studies (n = 3), a single thrombosis was reported and only ultrasound modality criterion met the standards. In the other studies (n = 15), all the criteria were appropriate except crew experience criterion, which was appropriate in only four studies. Future practice and research should account for microgravity-related changes, evaluate individual effect of venous interventions, and adopt Earth-based V-US standards.</p>\",\"PeriodicalId\":54263,\"journal\":{\"name\":\"npj Microgravity\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.4000,\"publicationDate\":\"2024-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10844233/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"npj Microgravity\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1038/s41526-024-00356-w\",\"RegionNum\":1,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MULTIDISCIPLINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"npj Microgravity","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41526-024-00356-w","RegionNum":1,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
Systematic review of the use of ultrasound for venous assessment and venous thrombosis screening in spaceflight.
The validity of venous ultrasound (V-US) for the diagnosis of deep vein thrombosis (DVT) during spaceflight is unknown and difficult to establish in diagnostic accuracy and diagnostic management studies in this context. We performed a systematic review of the use of V-US in the upper-body venous system in spaceflight to identify microgravity-related changes and the effect of venous interventions to reverse them, and to assess appropriateness of spaceflight V-US with terrestrial standards. An appropriateness tool was developed following expert panel discussions and review of terrestrial diagnostic studies, including criteria relevant to crew experience, in-flight equipment, assessment sites, ultrasound modalities, and DVT diagnosis. Microgravity-related findings reported as an increase in internal jugular vein (IJV) cross-sectional area and pressure were associated with reduced, stagnant, and retrograde flow. Changes were on average responsive to venous interventions using lower body negative pressure, Bracelets, Valsalva and Mueller manoeuvres, and contralateral IJV compression. In comparison with terrestrial standards, spaceflight V-US did not meet all appropriateness criteria. In DVT studies (n = 3), a single thrombosis was reported and only ultrasound modality criterion met the standards. In the other studies (n = 15), all the criteria were appropriate except crew experience criterion, which was appropriate in only four studies. Future practice and research should account for microgravity-related changes, evaluate individual effect of venous interventions, and adopt Earth-based V-US standards.
npj MicrogravityPhysics and Astronomy-Physics and Astronomy (miscellaneous)
CiteScore
7.30
自引率
7.80%
发文量
50
审稿时长
9 weeks
期刊介绍:
A new open access, online-only, multidisciplinary research journal, npj Microgravity is dedicated to publishing the most important scientific advances in the life sciences, physical sciences, and engineering fields that are facilitated by spaceflight and analogue platforms.