真实世界中的凝血检测:全面调查的启示

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-01-01 DOI:10.1177/10760296241228239
Hae In Bang, Ja Young Lee, Hyun-Young Kim, Saeam Shin, Myung Hyun Nam, In-Suk Kim, Ji Myung Kim, Jong-Hyun Yoon, Myung-Geun Shin, Sang Mee Hwang, Sun-Young Kong
{"title":"真实世界中的凝血检测:全面调查的启示","authors":"Hae In Bang, Ja Young Lee, Hyun-Young Kim, Saeam Shin, Myung Hyun Nam, In-Suk Kim, Ji Myung Kim, Jong-Hyun Yoon, Myung-Geun Shin, Sang Mee Hwang, Sun-Young Kong","doi":"10.1177/10760296241228239","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of this survey was to gain a real-world perspective on coagulation testing by evaluating the availability of various coagulation laboratory tests, assessing specific analytic and postanalytic steps in clinical laboratories in Korea.Participants were surveyed using a 65-question questionnaire specifically focused on their coagulation testing practices related to prothrombin time (PT), activated partial thromboplastin time (aPTT), plasma-mixing studies, lupus anticoagulant (LA) tests, platelet function tests, coagulation factor assays, and the composition of hemostasis and thrombosis test panels. The survey was performed between July and September 2022.The survey achieved a 77.9% (81 of 104) response rate. PT or aPTT tests were performed directly at all participating institutions, followed by D-dimer and fibrinogen tests, platelet function test, and plasma-mixing studies in order of frequency. Variations existed in the performance of mixing test and LA assessment. Patterns of coagulating testing differed depending on the size of the hospital. The survey revealed that most laboratories conducted coagulation tests following the international guidelines such as Clinical Laboratory Standards Institute guidelines and the Korean Laboratory Certification system. However, some coagulation tests, including mixing test and LA tests, are yet to be standardized in Korea.Continuous education on coagulation test methods and internal and external quality control are required to encourage laboratories to enhance the performance of coagulation testing.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10851719/pdf/","citationCount":"0","resultStr":"{\"title\":\"Coagulation Testing in Real-World Setting: Insights From a Comprehensive Survey.\",\"authors\":\"Hae In Bang, Ja Young Lee, Hyun-Young Kim, Saeam Shin, Myung Hyun Nam, In-Suk Kim, Ji Myung Kim, Jong-Hyun Yoon, Myung-Geun Shin, Sang Mee Hwang, Sun-Young Kong\",\"doi\":\"10.1177/10760296241228239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective of this survey was to gain a real-world perspective on coagulation testing by evaluating the availability of various coagulation laboratory tests, assessing specific analytic and postanalytic steps in clinical laboratories in Korea.Participants were surveyed using a 65-question questionnaire specifically focused on their coagulation testing practices related to prothrombin time (PT), activated partial thromboplastin time (aPTT), plasma-mixing studies, lupus anticoagulant (LA) tests, platelet function tests, coagulation factor assays, and the composition of hemostasis and thrombosis test panels. The survey was performed between July and September 2022.The survey achieved a 77.9% (81 of 104) response rate. PT or aPTT tests were performed directly at all participating institutions, followed by D-dimer and fibrinogen tests, platelet function test, and plasma-mixing studies in order of frequency. Variations existed in the performance of mixing test and LA assessment. Patterns of coagulating testing differed depending on the size of the hospital. The survey revealed that most laboratories conducted coagulation tests following the international guidelines such as Clinical Laboratory Standards Institute guidelines and the Korean Laboratory Certification system. However, some coagulation tests, including mixing test and LA tests, are yet to be standardized in Korea.Continuous education on coagulation test methods and internal and external quality control are required to encourage laboratories to enhance the performance of coagulation testing.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10851719/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/10760296241228239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10760296241228239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

这项调查的目的是通过评估各种凝血实验室检验的可用性,评估韩国临床实验室的具体分析步骤和分析后步骤,从而获得有关凝血检验的真实视角。调查采用 65 个问题的问卷形式,主要针对凝血酶原时间 (PT)、活化部分凝血活酶时间 (aPTT)、血浆混合研究、狼疮抗凝物 (LA) 检测、血小板功能检测、凝血因子检测以及止血和血栓检测组合的相关凝血检测方法。调查于 2022 年 7 月至 9 月间进行。调查的回复率为 77.9%(104 份回复中的 81 份)。所有参与调查的机构都直接进行了 PT 或 aPTT 检测,其次依次是 D-二聚体和纤维蛋白原检测、血小板功能检测和血浆混合研究。在混合试验和 LA 评估方面存在差异。医院规模不同,凝血检测的模式也不同。调查显示,大多数实验室都是按照临床实验室标准协会指南和韩国实验室认证体系等国际指南进行凝血检验的。为鼓励实验室提高凝血检验的性能,需要对凝血检验方法进行持续教育,并进行内部和外部质量控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Coagulation Testing in Real-World Setting: Insights From a Comprehensive Survey.

The objective of this survey was to gain a real-world perspective on coagulation testing by evaluating the availability of various coagulation laboratory tests, assessing specific analytic and postanalytic steps in clinical laboratories in Korea.Participants were surveyed using a 65-question questionnaire specifically focused on their coagulation testing practices related to prothrombin time (PT), activated partial thromboplastin time (aPTT), plasma-mixing studies, lupus anticoagulant (LA) tests, platelet function tests, coagulation factor assays, and the composition of hemostasis and thrombosis test panels. The survey was performed between July and September 2022.The survey achieved a 77.9% (81 of 104) response rate. PT or aPTT tests were performed directly at all participating institutions, followed by D-dimer and fibrinogen tests, platelet function test, and plasma-mixing studies in order of frequency. Variations existed in the performance of mixing test and LA assessment. Patterns of coagulating testing differed depending on the size of the hospital. The survey revealed that most laboratories conducted coagulation tests following the international guidelines such as Clinical Laboratory Standards Institute guidelines and the Korean Laboratory Certification system. However, some coagulation tests, including mixing test and LA tests, are yet to be standardized in Korea.Continuous education on coagulation test methods and internal and external quality control are required to encourage laboratories to enhance the performance of coagulation testing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1