传统经食道超声心动图与计算机断层扫描重建的 "虚拟经食道超声心动图 "对左心房阑尾测量结果的比较,用于装置闭合术前规划。

IF 1.4 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Heart and Vessels Pub Date : 2024-06-01 Epub Date: 2024-02-08 DOI:10.1007/s00380-024-02360-2
Natsuki Cho, Yoshifumi Nakajima, Shunsuke Kubo, Hidehiko Hara, Mamoru Nanasato, Maiko Hozawa, Akio Doi, Yoshihiro Morino
{"title":"传统经食道超声心动图与计算机断层扫描重建的 \"虚拟经食道超声心动图 \"对左心房阑尾测量结果的比较,用于装置闭合术前规划。","authors":"Natsuki Cho, Yoshifumi Nakajima, Shunsuke Kubo, Hidehiko Hara, Mamoru Nanasato, Maiko Hozawa, Akio Doi, Yoshihiro Morino","doi":"10.1007/s00380-024-02360-2","DOIUrl":null,"url":null,"abstract":"<p><p>For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.</p>","PeriodicalId":12940,"journal":{"name":"Heart and Vessels","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and \\\"Virtual TEE\\\" reconstructed from computed tomography for pre-procedural planning of device closure.\",\"authors\":\"Natsuki Cho, Yoshifumi Nakajima, Shunsuke Kubo, Hidehiko Hara, Mamoru Nanasato, Maiko Hozawa, Akio Doi, Yoshihiro Morino\",\"doi\":\"10.1007/s00380-024-02360-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.</p>\",\"PeriodicalId\":12940,\"journal\":{\"name\":\"Heart and Vessels\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart and Vessels\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00380-024-02360-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart and Vessels","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00380-024-02360-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/8 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

对于左心房阑尾(LAA)封堵术的术前规划,尺寸至关重要。虽然经食道超声心动图(TEE)是一种标准模式,但心脏计算机断层扫描(CT)也被广泛使用。我们小组开发的虚拟 TEE(V-TEE)可让我们从 CT 图像中重建与 TEE 图像相似的图像。该软件应有助于理解和规划手术策略。因此,我们对 V-TEE 的实用性进行了研究。我们纳入了 4 个参与研究地点的 66 名患者,他们在关闭 LAA 前都完成了 CT 和 TEE。对 V-TEE 和 TEE 在 0°、45°、90° 和 135°时植入 WATCHMAN™ 装置的着床区 (LZ) 的 LAA 直径进行了统计比较。在 66 个病例中,只有 3 个病例因成像质量不佳而被排除,因此分析了 63 个病例。基于 V-TEE 的装置 LZ 直径与基于 TEE 的装置 LZ 直径密切相关,尽管基于 V-TEE 的装置 LZ 直径明显更大,平均相差 2.4 至 3.0 mm(均为 2.4 mm):P
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of left atrial appendage measurements between conventional transesophageal echocardiography and "Virtual TEE" reconstructed from computed tomography for pre-procedural planning of device closure.

For pre-procedural planning of left atrial appendage (LAA) closure, sizing is crucial. Although transesophageal echocardiography (TEE) is a standard modality, cardiac computed tomography (CT) is also widely used. The virtual TEE (V-TEE) that our group developed enables us to reconstruct images similar to TEE images from CT images. The software should be helpful to understand and plan the procedure strategy. Accordingly, we investigated the utility of V-TEE. Sixty-six patients at 4 participating sites who completed both CT and TEE prior to LAA closure were included. The LAA diameter at the landing zone (LZ) for WATCHMAN™ device implantation was statistically compared at 0°, 45°, 90°, and 135° between V-TEE and TEE. Among 66 cases, only 3 cases were excluded due to poor imaging quality, and 63 cases were analyzed. The device LZ diameters based on V-TEE were strongly correlated with those based on TEE, despite the significantly greater diameter based on V-TEE with mean differences of 2.4 to 3.0 mm (all of them: P < 0.001). The discordances (V-TEE/TEE ratio) at most angles were significantly larger in the elliptical LAAs. V-TEE provides a valuable method for the evaluation of the LAA diameters. V-TEE-based measurements were larger than conventional TEE-based measurements, especially in cases of elliptical LAAs. The assessment by V-TEE has the potential benefit of ensuring proper device sizing regardless of the LAA morphology.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Heart and Vessels
Heart and Vessels 医学-外周血管病
CiteScore
3.10
自引率
13.30%
发文量
211
审稿时长
2 months
期刊介绍: Heart and Vessels is an English-language journal that provides a forum of original ideas, excellent methods, and fascinating techniques on cardiovascular disease fields. All papers submitted for publication are evaluated only with regard to scientific quality and relevance to the heart and vessels. Contributions from those engaged in practical medicine, as well as from those involved in basic research, are welcomed.
期刊最新文献
Association between high plasma levels of legumain and cardiovascular events in patients undergoing coronary angiography. Changes in the diagnostic trajectory of transthyretin cardiac amyloidosis over six years. Plasma microRNA-143 and microRNA-145 levels are elevated in patients with left ventricular dysfunction. Bilateral pulmonary artery banding facilitates the systemic ventricular outflow tract growth for biventricular and univentricular repair candidates of complex arch anomaly. Evaluation of novel indices of walking performance taking oxygen desaturation into account during six-minute walk test in cardiovascular disease patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1