肥胖症青年男子在最大脂肪含量下进行稳态运动时的代谢反应的可靠性。

Isaac A Chávez-Guevara, Ratko Peric, Francisco J Amaro-Gahete, Arnulfo Ramos-Jiménez
{"title":"肥胖症青年男子在最大脂肪含量下进行稳态运动时的代谢反应的可靠性。","authors":"Isaac A Chávez-Guevara, Ratko Peric, Francisco J Amaro-Gahete, Arnulfo Ramos-Jiménez","doi":"10.1080/02701367.2024.2311641","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose</b>: In this study we evaluated the reliability of blood lactate levels (BLa), energy expenditure and substrate utilization during prolonged exercise at the intensity that elicits maximal fat oxidation (FATmax). Furthermore, we investigated the accuracy of a single graded exercise test (GXT) for predicting energy metabolism at FATmax. <b>Methods</b>: Seventeen young men with obesity (26 ± 6 years; 36.4 ± 7.2 %body fat) performed a GXT on a treadmill in a fasted state (10-12 h) for the assessment of FATmax and cardiorespiratory fitness. Afterward, each subject performed two additional prolonged FATmax trials (102 ± 11 beats·min<sup>-1</sup>; 60-min) separated by 7 days. Indirect calorimetry was used for the assessment of energy expenditure and substrate utilization kinetics whereas capillary blood samples were taken for the measurement of BLa. <b>Results</b>: The BLa (limits of agreement (LoA): -1.2 to 0.8 mmol∙L<sup>-1</sup>; <i>p</i> = 1.0), fat utilization (LoA: -8.0 to 13.4 g∙h<sup>-1</sup>; <i>p</i> = 0.06), and carbohydrate utilization (LoA: -27.6 to 22.4 g∙h<sup>-1</sup>; <i>p</i> = 0.41) showed a good agreement whereas a modest systematic bias was found for energy expenditure (LoA: -16811 to 33355 kJ∙h<sup>-1</sup>; <i>p</i> < 0.05). All the aforementioned parameters showed a moderate to good reliability (Intraclass correlation coefficient: 0.67-0.92). The GXT overestimated fat (~46%) and carbohydrate (~26%) utilization as well as energy expenditure (36%) during steady-state exercise at FATmax. Conversely the GXT underestimated BLa (~28%). <b>Conclusion</b>: a single GXT cannot be used for an accurate prediction of energy metabolism during prolonged exercise in men with obesity. Thus, an additional steady-state FATmax trial (40-60 min) should be performed for a tailored and precise exercise prescription.</p>","PeriodicalId":94191,"journal":{"name":"Research quarterly for exercise and sport","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reliability of the Metabolic Response During Steady-State Exercise at FATmax in Young Men with Obesity.\",\"authors\":\"Isaac A Chávez-Guevara, Ratko Peric, Francisco J Amaro-Gahete, Arnulfo Ramos-Jiménez\",\"doi\":\"10.1080/02701367.2024.2311641\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Purpose</b>: In this study we evaluated the reliability of blood lactate levels (BLa), energy expenditure and substrate utilization during prolonged exercise at the intensity that elicits maximal fat oxidation (FATmax). Furthermore, we investigated the accuracy of a single graded exercise test (GXT) for predicting energy metabolism at FATmax. <b>Methods</b>: Seventeen young men with obesity (26 ± 6 years; 36.4 ± 7.2 %body fat) performed a GXT on a treadmill in a fasted state (10-12 h) for the assessment of FATmax and cardiorespiratory fitness. Afterward, each subject performed two additional prolonged FATmax trials (102 ± 11 beats·min<sup>-1</sup>; 60-min) separated by 7 days. Indirect calorimetry was used for the assessment of energy expenditure and substrate utilization kinetics whereas capillary blood samples were taken for the measurement of BLa. <b>Results</b>: The BLa (limits of agreement (LoA): -1.2 to 0.8 mmol∙L<sup>-1</sup>; <i>p</i> = 1.0), fat utilization (LoA: -8.0 to 13.4 g∙h<sup>-1</sup>; <i>p</i> = 0.06), and carbohydrate utilization (LoA: -27.6 to 22.4 g∙h<sup>-1</sup>; <i>p</i> = 0.41) showed a good agreement whereas a modest systematic bias was found for energy expenditure (LoA: -16811 to 33355 kJ∙h<sup>-1</sup>; <i>p</i> < 0.05). All the aforementioned parameters showed a moderate to good reliability (Intraclass correlation coefficient: 0.67-0.92). The GXT overestimated fat (~46%) and carbohydrate (~26%) utilization as well as energy expenditure (36%) during steady-state exercise at FATmax. Conversely the GXT underestimated BLa (~28%). <b>Conclusion</b>: a single GXT cannot be used for an accurate prediction of energy metabolism during prolonged exercise in men with obesity. Thus, an additional steady-state FATmax trial (40-60 min) should be performed for a tailored and precise exercise prescription.</p>\",\"PeriodicalId\":94191,\"journal\":{\"name\":\"Research quarterly for exercise and sport\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Research quarterly for exercise and sport\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/02701367.2024.2311641\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research quarterly for exercise and sport","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/02701367.2024.2311641","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:在本研究中,我们评估了在最大脂肪氧化(FATmax)强度下进行长时间运动时,血液乳酸水平(BLa)、能量消耗和底物利用的可靠性。此外,我们还研究了单一分级运动测试(GXT)预测最大脂肪氧化时能量代谢的准确性。研究方法17 名年轻肥胖男性(26 ± 6 岁;36.4 ± 7.2 % 体脂)在空腹状态(10-12 小时)下在跑步机上进行了 GXT,以评估脂肪消耗最大值和心肺功能。之后,每个受试者又进行了两次延长的最大脂肪量试验(102 ± 11 次/分钟-1;60 分钟),每次间隔 7 天。间接热量计用于评估能量消耗和底物利用动力学,而毛细血管血液样本则用于测量 BLa。结果BLa(一致性限值(LoA):-1.2 至 0.8 mmol∙L-1; p = 1.0)、脂肪利用率(LoA:-8.0 至 13.4 g∙h-1; p = 0.06)和碳水化合物利用率(LoA:-27.6 至 22.4 g∙h-1; p = 0.41)显示出良好的一致性,而能量消耗(LoA:-16811 至 33355 kJ∙h-1; p < 0.05)显示出适度的系统性偏差。上述所有参数均显示出中等至良好的可靠性(类内相关系数:0.67-0.92)。GXT 高估了脂肪(约 46%)和碳水化合物(约 26%)的利用率,以及在 FATmax 稳态运动时的能量消耗(36%)。相反,GXT 低估了 BLa(约 28%)。结论:单一的 GXT 不能用于准确预测肥胖男性在长时间运动时的能量代谢。因此,应进行额外的稳态 FATmax 试验(40-60 分钟),以量身定制精确的运动处方。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability of the Metabolic Response During Steady-State Exercise at FATmax in Young Men with Obesity.

Purpose: In this study we evaluated the reliability of blood lactate levels (BLa), energy expenditure and substrate utilization during prolonged exercise at the intensity that elicits maximal fat oxidation (FATmax). Furthermore, we investigated the accuracy of a single graded exercise test (GXT) for predicting energy metabolism at FATmax. Methods: Seventeen young men with obesity (26 ± 6 years; 36.4 ± 7.2 %body fat) performed a GXT on a treadmill in a fasted state (10-12 h) for the assessment of FATmax and cardiorespiratory fitness. Afterward, each subject performed two additional prolonged FATmax trials (102 ± 11 beats·min-1; 60-min) separated by 7 days. Indirect calorimetry was used for the assessment of energy expenditure and substrate utilization kinetics whereas capillary blood samples were taken for the measurement of BLa. Results: The BLa (limits of agreement (LoA): -1.2 to 0.8 mmol∙L-1; p = 1.0), fat utilization (LoA: -8.0 to 13.4 g∙h-1; p = 0.06), and carbohydrate utilization (LoA: -27.6 to 22.4 g∙h-1; p = 0.41) showed a good agreement whereas a modest systematic bias was found for energy expenditure (LoA: -16811 to 33355 kJ∙h-1; p < 0.05). All the aforementioned parameters showed a moderate to good reliability (Intraclass correlation coefficient: 0.67-0.92). The GXT overestimated fat (~46%) and carbohydrate (~26%) utilization as well as energy expenditure (36%) during steady-state exercise at FATmax. Conversely the GXT underestimated BLa (~28%). Conclusion: a single GXT cannot be used for an accurate prediction of energy metabolism during prolonged exercise in men with obesity. Thus, an additional steady-state FATmax trial (40-60 min) should be performed for a tailored and precise exercise prescription.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Influence of Mental Fatigue on Physical Performance and Its Relationship with Rating Perceived Effort and Enjoyment in Older Adults. Greater Excess Post-Exercise Oxygen Consumption and Fat Use Following Calisthenics vs. Oxygen Consumption Matched Steady-State Exercise. Muscle Hypertrophy and Strength Adaptations to Systematically Varying Resistance Exercises. The Effect of Attention Focus Instructions on Strength and Balance in Subjects With Generalized Joint Hypermobility. Neural and Muscular Determinants of Performance Fatigability Are Independent of Work and Recovery Durations During High-Intensity Interval Exercise in Males.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1