{"title":"从医生角度评估电子处方系统的可用性:伊朗南部案例研究","authors":"Mohammad Hosein Hayavi-Haghighi , Somayeh Davoodi , Saeed Hossini Teshnizi , Razieh Jookar","doi":"10.1016/j.imu.2024.101460","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The evaluation of e-prescribing systems' usability is crucial as they are integral to the quality of healthcare services. This study evaluates the usability of three e-prescribing systems and examines the impact of individual factors on system usability.</p></div><div><h3>Method</h3><p>The objective of this descriptive study was to assess the usability of e-prescribing systems (EP, Dinad, and Shafa) as perceived by 105 physicians from three clinics at Hormozgan University of Medical Sciences in Bandar Abbas, Iran. The data was collected using the 2020 edition of the Isometric Questionnaire 9241/110, which comprises of seven axes and 66 questions. The participants were asked to rate their opinions on a 5-point Likert scale, with options ranging from completely disagree [1] to completely agree [5].</p></div><div><h3>Results</h3><p>EP, Dinad, and Shafa received average scores of 3.45, 3.32, and 3.24, respectively. Self-descriptiveness and User Error Tolerance axes were rated the highest ratings, with average scores of 3.60 and 3.48. Conversely, conformity and suitability axes received the lowest ratings, with average scores of 3.19 and 3.22, respectively. Upon evaluating the usability axes, the EP significantly improved controllability and user engagement compared to other systems. The usability of Dinad and Shafa in the Gynecology clinic was significantly higher than the two other clinics. Also, older physicians with more work experience rated the Shafa significantly higher than two other systems.</p></div><div><h3>Conclusion</h3><p>The evaluated systems had average usability. although there was no statistically significant difference in the usability of these systems, the evaluation of dimensions revealed unique strengths in each system.</p></div>","PeriodicalId":13953,"journal":{"name":"Informatics in Medicine Unlocked","volume":"45 ","pages":"Article 101460"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352914824000169/pdfft?md5=dcfd36af8f38f00e28885b20de141cda&pid=1-s2.0-S2352914824000169-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Usability evaluation of electronic prescribing systems from physician' perspective: A case study from southern Iran\",\"authors\":\"Mohammad Hosein Hayavi-Haghighi , Somayeh Davoodi , Saeed Hossini Teshnizi , Razieh Jookar\",\"doi\":\"10.1016/j.imu.2024.101460\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>The evaluation of e-prescribing systems' usability is crucial as they are integral to the quality of healthcare services. This study evaluates the usability of three e-prescribing systems and examines the impact of individual factors on system usability.</p></div><div><h3>Method</h3><p>The objective of this descriptive study was to assess the usability of e-prescribing systems (EP, Dinad, and Shafa) as perceived by 105 physicians from three clinics at Hormozgan University of Medical Sciences in Bandar Abbas, Iran. The data was collected using the 2020 edition of the Isometric Questionnaire 9241/110, which comprises of seven axes and 66 questions. The participants were asked to rate their opinions on a 5-point Likert scale, with options ranging from completely disagree [1] to completely agree [5].</p></div><div><h3>Results</h3><p>EP, Dinad, and Shafa received average scores of 3.45, 3.32, and 3.24, respectively. Self-descriptiveness and User Error Tolerance axes were rated the highest ratings, with average scores of 3.60 and 3.48. Conversely, conformity and suitability axes received the lowest ratings, with average scores of 3.19 and 3.22, respectively. Upon evaluating the usability axes, the EP significantly improved controllability and user engagement compared to other systems. The usability of Dinad and Shafa in the Gynecology clinic was significantly higher than the two other clinics. Also, older physicians with more work experience rated the Shafa significantly higher than two other systems.</p></div><div><h3>Conclusion</h3><p>The evaluated systems had average usability. although there was no statistically significant difference in the usability of these systems, the evaluation of dimensions revealed unique strengths in each system.</p></div>\",\"PeriodicalId\":13953,\"journal\":{\"name\":\"Informatics in Medicine Unlocked\",\"volume\":\"45 \",\"pages\":\"Article 101460\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2352914824000169/pdfft?md5=dcfd36af8f38f00e28885b20de141cda&pid=1-s2.0-S2352914824000169-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Informatics in Medicine Unlocked\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2352914824000169\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informatics in Medicine Unlocked","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352914824000169","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
Usability evaluation of electronic prescribing systems from physician' perspective: A case study from southern Iran
Introduction
The evaluation of e-prescribing systems' usability is crucial as they are integral to the quality of healthcare services. This study evaluates the usability of three e-prescribing systems and examines the impact of individual factors on system usability.
Method
The objective of this descriptive study was to assess the usability of e-prescribing systems (EP, Dinad, and Shafa) as perceived by 105 physicians from three clinics at Hormozgan University of Medical Sciences in Bandar Abbas, Iran. The data was collected using the 2020 edition of the Isometric Questionnaire 9241/110, which comprises of seven axes and 66 questions. The participants were asked to rate their opinions on a 5-point Likert scale, with options ranging from completely disagree [1] to completely agree [5].
Results
EP, Dinad, and Shafa received average scores of 3.45, 3.32, and 3.24, respectively. Self-descriptiveness and User Error Tolerance axes were rated the highest ratings, with average scores of 3.60 and 3.48. Conversely, conformity and suitability axes received the lowest ratings, with average scores of 3.19 and 3.22, respectively. Upon evaluating the usability axes, the EP significantly improved controllability and user engagement compared to other systems. The usability of Dinad and Shafa in the Gynecology clinic was significantly higher than the two other clinics. Also, older physicians with more work experience rated the Shafa significantly higher than two other systems.
Conclusion
The evaluated systems had average usability. although there was no statistically significant difference in the usability of these systems, the evaluation of dimensions revealed unique strengths in each system.
期刊介绍:
Informatics in Medicine Unlocked (IMU) is an international gold open access journal covering a broad spectrum of topics within medical informatics, including (but not limited to) papers focusing on imaging, pathology, teledermatology, public health, ophthalmological, nursing and translational medicine informatics. The full papers that are published in the journal are accessible to all who visit the website.