基于 ITK 三维标注的鼻骨骨折患者计算机断层扫描参数改进研究

IF 1.1 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Current Medical Imaging Reviews Pub Date : 2024-02-09 DOI:10.2174/0115734056250334231214054003
Lei Yang, Cun Yang, Guo-Dong Gao, Ying Li, Liang Li, Xue-Fang Han, Jin-Hui Dong
{"title":"基于 ITK 三维标注的鼻骨骨折患者计算机断层扫描参数改进研究","authors":"Lei Yang, Cun Yang, Guo-Dong Gao, Ying Li, Liang Li, Xue-Fang Han, Jin-Hui Dong","doi":"10.2174/0115734056250334231214054003","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the influence of improved exposure parameters on the image quality of multi-slice spiral computed tomography in nasal bone fracture imaging.</p><p><strong>Methods: </strong>Fifty patients with optimised parameters combined with coronal scanning were allocated to the modified group and 50 patients with routine scanning parameters to the routine group. The image quality and nasal bone display of the two groups were assessed and statistically analysed, and the quality of scanned images before and after parameter optimisation was compared.</p><p><strong>Results: </strong>The optimised image quality was better than that of conventional scanning parameters. The parameters used were 120 kv, 180 mA, a layer thickness of 0.625 mm, a layer spacing of 0.312 mm, a pitch of 0.516:1, a frame speed of 1 s, a scanning field of 12 cm and a reconstructed layer thickness for scanning of 0.625 mm; the scanned image was clear, and the parameter optimisation was achieved. This ensures that the annotation data in ITK labelling is more accurate.</p><p><strong>Conclusion: </strong>The optimised parameters and scanned coronal plane show the nasal bone and its surrounding structures more comprehensively, which is of high diagnostic value for nasal bone fractures. The three-dimensional annotation data based on ITK is more standardised, laying a foundation for the subsequent research of artificial intelligence modelling.</p>","PeriodicalId":54215,"journal":{"name":"Current Medical Imaging Reviews","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on Improved Computed Tomography Scanning Parameters for Patients with Nasal Bone Fracture Based on ITK Three-dimensional Labelling.\",\"authors\":\"Lei Yang, Cun Yang, Guo-Dong Gao, Ying Li, Liang Li, Xue-Fang Han, Jin-Hui Dong\",\"doi\":\"10.2174/0115734056250334231214054003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the influence of improved exposure parameters on the image quality of multi-slice spiral computed tomography in nasal bone fracture imaging.</p><p><strong>Methods: </strong>Fifty patients with optimised parameters combined with coronal scanning were allocated to the modified group and 50 patients with routine scanning parameters to the routine group. The image quality and nasal bone display of the two groups were assessed and statistically analysed, and the quality of scanned images before and after parameter optimisation was compared.</p><p><strong>Results: </strong>The optimised image quality was better than that of conventional scanning parameters. The parameters used were 120 kv, 180 mA, a layer thickness of 0.625 mm, a layer spacing of 0.312 mm, a pitch of 0.516:1, a frame speed of 1 s, a scanning field of 12 cm and a reconstructed layer thickness for scanning of 0.625 mm; the scanned image was clear, and the parameter optimisation was achieved. This ensures that the annotation data in ITK labelling is more accurate.</p><p><strong>Conclusion: </strong>The optimised parameters and scanned coronal plane show the nasal bone and its surrounding structures more comprehensively, which is of high diagnostic value for nasal bone fractures. The three-dimensional annotation data based on ITK is more standardised, laying a foundation for the subsequent research of artificial intelligence modelling.</p>\",\"PeriodicalId\":54215,\"journal\":{\"name\":\"Current Medical Imaging Reviews\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-02-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Medical Imaging Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2174/0115734056250334231214054003\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Medical Imaging Reviews","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/0115734056250334231214054003","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究改进的曝光参数对鼻骨骨折成像中多层螺旋计算机断层扫描图像质量的影响:研究改进曝光参数对鼻骨骨折成像中多层螺旋计算机断层扫描图像质量的影响:将 50 名使用优化参数结合冠状扫描的患者分配到改进组,将 50 名使用常规扫描参数的患者分配到常规组。对两组患者的图像质量和鼻骨显示进行评估和统计分析,并对参数优化前后的扫描图像质量进行比较:结果:优化后的图像质量优于常规扫描参数。使用的参数为 120 kv、180 mA、层厚 0.625 mm、层间距 0.312 mm、间距 0.516:1、帧速 1 s、扫描区域 12 cm、扫描重建层厚 0.625 mm;扫描图像清晰,实现了参数优化。这确保了 ITK 标记中的注释数据更加准确:结论:优化后的参数和扫描冠状面能更全面地显示鼻骨及其周围结构,对鼻骨骨折有很高的诊断价值。基于 ITK 的三维标注数据更加标准化,为后续的人工智能建模研究奠定了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on Improved Computed Tomography Scanning Parameters for Patients with Nasal Bone Fracture Based on ITK Three-dimensional Labelling.

Objective: To investigate the influence of improved exposure parameters on the image quality of multi-slice spiral computed tomography in nasal bone fracture imaging.

Methods: Fifty patients with optimised parameters combined with coronal scanning were allocated to the modified group and 50 patients with routine scanning parameters to the routine group. The image quality and nasal bone display of the two groups were assessed and statistically analysed, and the quality of scanned images before and after parameter optimisation was compared.

Results: The optimised image quality was better than that of conventional scanning parameters. The parameters used were 120 kv, 180 mA, a layer thickness of 0.625 mm, a layer spacing of 0.312 mm, a pitch of 0.516:1, a frame speed of 1 s, a scanning field of 12 cm and a reconstructed layer thickness for scanning of 0.625 mm; the scanned image was clear, and the parameter optimisation was achieved. This ensures that the annotation data in ITK labelling is more accurate.

Conclusion: The optimised parameters and scanned coronal plane show the nasal bone and its surrounding structures more comprehensively, which is of high diagnostic value for nasal bone fractures. The three-dimensional annotation data based on ITK is more standardised, laying a foundation for the subsequent research of artificial intelligence modelling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
246
审稿时长
1 months
期刊介绍: Current Medical Imaging Reviews publishes frontier review articles, original research articles, drug clinical trial studies and guest edited thematic issues on all the latest advances on medical imaging dedicated to clinical research. All relevant areas are covered by the journal, including advances in the diagnosis, instrumentation and therapeutic applications related to all modern medical imaging techniques. The journal is essential reading for all clinicians and researchers involved in medical imaging and diagnosis.
期刊最新文献
Advanced Lung Disease Detection: CBAM-Augmented, Lightweight EfficientNetB2 with Visual Insights. Multiple Pulmonary Sclerosing Haemangiomas with a Cavity: A Case Report and Review of the Literature. An Integrated Approach using YOLOv8 and ResNet, SeResNet & Vision Transformer (ViT) Algorithms based on ROI Fracture Prediction in X-ray Images of the Elbow. Combination of Different Sectional Elastography Techniques with Age to Optimize the Downgrading of Breast BI-RAIDS Class 4a Nodules. Prenatal Three-Dimensional Ultrasound Diagnosis of Dural Sinus Arteriovenous Malformation: An Unusual Case Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1