厚度对单色树脂复合材料透光度参数和白度指数的影响

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Operative dentistry Pub Date : 2024-03-01 DOI:10.2341/23-053-L
Ö Yağcı, M Fidan
{"title":"厚度对单色树脂复合材料透光度参数和白度指数的影响","authors":"Ö Yağcı, M Fidan","doi":"10.2341/23-053-L","DOIUrl":null,"url":null,"abstract":"<p><p>The study aimed to evaluate the effect of thickness on the translucency parameter (TP) and whiteness index for dentistry (WID) of single-shade resin composites compared with a multi-shade resin composite after thermocycling. A total of 100 resin composite samples of five brands (Filtek Z250, Omnichroma, Vittra APS Unique, Zenchroma, and Charisma Diamond One) with thicknesses of 2 mm and 4 mm were prepared (n=10). CIE L*a*b* coordinates were obtained using a spectrophotometer. The resin composite samples were subjected to 10,000 thermocycles. Before and after thermocycling, TP values were calculated with the CIEDE2000 formula, and whiteness values were calculated using the WID. The influence of thickness, resin composite, and aging on these variables was analyzed using the generalized linear model (p<0.05). Omnichroma and Filtek Z250 exhibited, respectively, the highest and the lowest TP00 values compared with the other resin materials (p<0.001). The TP00 values of Zenchroma and Diamond One were similar (p>0.05). Vittra APS Unique had a lower TP than Zenchroma and Diamond One (p<0.001). Before thermocycling, the highest WID showed the combination of Vittra APS Unique with thicknesses of 2 mm (48.33±1.18). After thermocycling, the highest WID was shown in the combination of Vittra APS Unique with thicknesses of 2 mm (45.33±0.55) and 4 mm (46.23±0.94) (p<0.001). After thermocycling, the lowest WID was for the combination of Filtek Z250 with thicknesses 2 mm (21.16±0.93) and 4 mm (20.70±0.91) (p<0.001). The TP and WID values of the resin composites varied across different composites and thicknesses. Single-shade resin composites of different thicknesses demonstrated higher translucency and whiteness values than multi-shade resin composite, both before and after thermocycling.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Thickness on the Translucency Parameter and Whiteness Index of Single-Shade Resin Composites.\",\"authors\":\"Ö Yağcı, M Fidan\",\"doi\":\"10.2341/23-053-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The study aimed to evaluate the effect of thickness on the translucency parameter (TP) and whiteness index for dentistry (WID) of single-shade resin composites compared with a multi-shade resin composite after thermocycling. A total of 100 resin composite samples of five brands (Filtek Z250, Omnichroma, Vittra APS Unique, Zenchroma, and Charisma Diamond One) with thicknesses of 2 mm and 4 mm were prepared (n=10). CIE L*a*b* coordinates were obtained using a spectrophotometer. The resin composite samples were subjected to 10,000 thermocycles. Before and after thermocycling, TP values were calculated with the CIEDE2000 formula, and whiteness values were calculated using the WID. The influence of thickness, resin composite, and aging on these variables was analyzed using the generalized linear model (p<0.05). Omnichroma and Filtek Z250 exhibited, respectively, the highest and the lowest TP00 values compared with the other resin materials (p<0.001). The TP00 values of Zenchroma and Diamond One were similar (p>0.05). Vittra APS Unique had a lower TP than Zenchroma and Diamond One (p<0.001). Before thermocycling, the highest WID showed the combination of Vittra APS Unique with thicknesses of 2 mm (48.33±1.18). After thermocycling, the highest WID was shown in the combination of Vittra APS Unique with thicknesses of 2 mm (45.33±0.55) and 4 mm (46.23±0.94) (p<0.001). After thermocycling, the lowest WID was for the combination of Filtek Z250 with thicknesses 2 mm (21.16±0.93) and 4 mm (20.70±0.91) (p<0.001). The TP and WID values of the resin composites varied across different composites and thicknesses. Single-shade resin composites of different thicknesses demonstrated higher translucency and whiteness values than multi-shade resin composite, both before and after thermocycling.</p>\",\"PeriodicalId\":19502,\"journal\":{\"name\":\"Operative dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Operative dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2341/23-053-L\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-053-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

该研究旨在评估单色调树脂复合材料与多色调树脂复合材料在热循环后厚度对半透明参数(TP)和牙科白度指数(WID)的影响。共制备了 100 份厚度为 2 毫米和 4 毫米的五种品牌(Filtek Z250、Omnichroma、Vittra APS Unique、Zenchroma 和 Charisma Diamond One)树脂复合材料样品(n=10)。使用分光光度计获得 CIE L*a*b* 坐标。对树脂复合材料样品进行 10,000 次热循环。热循环前后的 TP 值用 CIEDE2000 公式计算,白度值用 WID 计算。使用广义线性模型分析了厚度、树脂复合材料和老化对这些变量的影响(p0.05)。Vittra APS Unique 的 TP 值低于 Zenchroma 和 Diamond One(P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Thickness on the Translucency Parameter and Whiteness Index of Single-Shade Resin Composites.

The study aimed to evaluate the effect of thickness on the translucency parameter (TP) and whiteness index for dentistry (WID) of single-shade resin composites compared with a multi-shade resin composite after thermocycling. A total of 100 resin composite samples of five brands (Filtek Z250, Omnichroma, Vittra APS Unique, Zenchroma, and Charisma Diamond One) with thicknesses of 2 mm and 4 mm were prepared (n=10). CIE L*a*b* coordinates were obtained using a spectrophotometer. The resin composite samples were subjected to 10,000 thermocycles. Before and after thermocycling, TP values were calculated with the CIEDE2000 formula, and whiteness values were calculated using the WID. The influence of thickness, resin composite, and aging on these variables was analyzed using the generalized linear model (p<0.05). Omnichroma and Filtek Z250 exhibited, respectively, the highest and the lowest TP00 values compared with the other resin materials (p<0.001). The TP00 values of Zenchroma and Diamond One were similar (p>0.05). Vittra APS Unique had a lower TP than Zenchroma and Diamond One (p<0.001). Before thermocycling, the highest WID showed the combination of Vittra APS Unique with thicknesses of 2 mm (48.33±1.18). After thermocycling, the highest WID was shown in the combination of Vittra APS Unique with thicknesses of 2 mm (45.33±0.55) and 4 mm (46.23±0.94) (p<0.001). After thermocycling, the lowest WID was for the combination of Filtek Z250 with thicknesses 2 mm (21.16±0.93) and 4 mm (20.70±0.91) (p<0.001). The TP and WID values of the resin composites varied across different composites and thicknesses. Single-shade resin composites of different thicknesses demonstrated higher translucency and whiteness values than multi-shade resin composite, both before and after thermocycling.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
期刊最新文献
Influence of Battery Levels in Cordless LED Light-curing Units on Properties of Resin Cement and Glass Fiber Post Retention. Effect of Bleaching Treatments on the Mechanical Properties of the Dentin Matrix and on Collagen Biodegradation by Endogenous Protease. Effect of Radiotherapy on the Adhesive Interface of Caries-affected Dentin and Bioactive Restorations: A Micro-CT Analysis. Effect of Surface Treatment with Zirconium Dioxide Slurry on the Bond Strength of Resin Cement to Ultratranslucent Zirconia. Flexural Properties, Wear Resistance, and Microstructural Analysis of Highly Filled Flowable Resin Composites.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1