Raúl E Ríos-Méndez, María E Araúz-Martínez, Jorge A Oliveros-Rivero, Yeiber J Crespo-Gutiérrez, Yesenia W Pérez-Vite
{"title":"[用 OcclutechTM 装置闭合动脉导管未闭,一个安第斯国家的经验]。","authors":"Raúl E Ríos-Méndez, María E Araúz-Martínez, Jorge A Oliveros-Rivero, Yeiber J Crespo-Gutiérrez, Yesenia W Pérez-Vite","doi":"10.24875/ACM.23000126","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>To communicate the experience in an Andean country with the OcclutechTM Duct Occluder device for the closure of patent ductus arteriosus.</p><p><strong>Method: </strong>observational, retrospective, cross-sectional study with basic statistical analysis. Period: December/2014 to December/2022. Data: medical chart, reports of catheterization.</p><p><strong>Results: </strong>Forty-six patients, female 71.3%, male 28.7%; age: 0.6-38 years-old (median [Me]: 5.2); weight: 6.3-60 kg (Me: 16.5). Origin: Andean 91.3%, coast 8.7%. Types of patent ductus arteriosus: E 54.4%, A 32.6%, D 13%. Minimum ductal diameter: 1.8-11.8 mm (Me: 3.5). Mean pulmonary artery pressure prior to occlusion: 14-67 mmHg (Me: 27). Pulmonary vascular resistance index prior to occlusion: 0.28-4.9 WU/m2 (Me: 1.3). Six of them were classified as hypertensive patent ductus arteriosus. Occlusion rate: 47.8% immediate, 81% at 24 hours, 100% after six months. Fluoroscopy time: 2-13.8 minutes (Me: 4). Complications: a migrated device. Follow-up: 1-6.5 years.</p><p><strong>Conclusions: </strong>Occlutech<sup>TM</sup> Duct Occluder device was effective and safe for the closure of patent ductus arteriosus type E, A and D in low-altitude and high-altitude dwellers, whether they were children or adults, even when these ductus arteriosus were hypertensive.</p>","PeriodicalId":93885,"journal":{"name":"Archivos de cardiologia de Mexico","volume":" ","pages":"169-173"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11160539/pdf/","citationCount":"0","resultStr":"{\"title\":\"[Closure of patent ductus arteriosus with Occlutech<sup>TM</sup> device, experience in an andean country].\",\"authors\":\"Raúl E Ríos-Méndez, María E Araúz-Martínez, Jorge A Oliveros-Rivero, Yeiber J Crespo-Gutiérrez, Yesenia W Pérez-Vite\",\"doi\":\"10.24875/ACM.23000126\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objective: </strong>To communicate the experience in an Andean country with the OcclutechTM Duct Occluder device for the closure of patent ductus arteriosus.</p><p><strong>Method: </strong>observational, retrospective, cross-sectional study with basic statistical analysis. Period: December/2014 to December/2022. Data: medical chart, reports of catheterization.</p><p><strong>Results: </strong>Forty-six patients, female 71.3%, male 28.7%; age: 0.6-38 years-old (median [Me]: 5.2); weight: 6.3-60 kg (Me: 16.5). Origin: Andean 91.3%, coast 8.7%. Types of patent ductus arteriosus: E 54.4%, A 32.6%, D 13%. Minimum ductal diameter: 1.8-11.8 mm (Me: 3.5). Mean pulmonary artery pressure prior to occlusion: 14-67 mmHg (Me: 27). Pulmonary vascular resistance index prior to occlusion: 0.28-4.9 WU/m2 (Me: 1.3). Six of them were classified as hypertensive patent ductus arteriosus. Occlusion rate: 47.8% immediate, 81% at 24 hours, 100% after six months. Fluoroscopy time: 2-13.8 minutes (Me: 4). Complications: a migrated device. Follow-up: 1-6.5 years.</p><p><strong>Conclusions: </strong>Occlutech<sup>TM</sup> Duct Occluder device was effective and safe for the closure of patent ductus arteriosus type E, A and D in low-altitude and high-altitude dwellers, whether they were children or adults, even when these ductus arteriosus were hypertensive.</p>\",\"PeriodicalId\":93885,\"journal\":{\"name\":\"Archivos de cardiologia de Mexico\",\"volume\":\" \",\"pages\":\"169-173\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11160539/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos de cardiologia de Mexico\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24875/ACM.23000126\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos de cardiologia de Mexico","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24875/ACM.23000126","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Closure of patent ductus arteriosus with OcclutechTM device, experience in an andean country].
Background and objective: To communicate the experience in an Andean country with the OcclutechTM Duct Occluder device for the closure of patent ductus arteriosus.
Method: observational, retrospective, cross-sectional study with basic statistical analysis. Period: December/2014 to December/2022. Data: medical chart, reports of catheterization.
Results: Forty-six patients, female 71.3%, male 28.7%; age: 0.6-38 years-old (median [Me]: 5.2); weight: 6.3-60 kg (Me: 16.5). Origin: Andean 91.3%, coast 8.7%. Types of patent ductus arteriosus: E 54.4%, A 32.6%, D 13%. Minimum ductal diameter: 1.8-11.8 mm (Me: 3.5). Mean pulmonary artery pressure prior to occlusion: 14-67 mmHg (Me: 27). Pulmonary vascular resistance index prior to occlusion: 0.28-4.9 WU/m2 (Me: 1.3). Six of them were classified as hypertensive patent ductus arteriosus. Occlusion rate: 47.8% immediate, 81% at 24 hours, 100% after six months. Fluoroscopy time: 2-13.8 minutes (Me: 4). Complications: a migrated device. Follow-up: 1-6.5 years.
Conclusions: OcclutechTM Duct Occluder device was effective and safe for the closure of patent ductus arteriosus type E, A and D in low-altitude and high-altitude dwellers, whether they were children or adults, even when these ductus arteriosus were hypertensive.