Eric Anderson, Sierra W. Malis, Anna J. Osterholtz, Molly K. Zuckerman
{"title":"调查便携式骨测量仪的可靠性和有效性","authors":"Eric Anderson, Sierra W. Malis, Anna J. Osterholtz, Molly K. Zuckerman","doi":"10.1017/aap.2023.33","DOIUrl":null,"url":null,"abstract":"\n Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"7 8","pages":""},"PeriodicalIF":16.4000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigating the Reliability and Validity of the Portable Osteometric Device\",\"authors\":\"Eric Anderson, Sierra W. Malis, Anna J. Osterholtz, Molly K. Zuckerman\",\"doi\":\"10.1017/aap.2023.33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":\"7 8\",\"pages\":\"\"},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/aap.2023.33\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/aap.2023.33","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Investigating the Reliability and Validity of the Portable Osteometric Device
Metric analysis of skeletal material is integral to the analysis and identification of human remains, though one commonly used measuring device, the osteometric board, has lagged in recent advancement. Traditional boards are bulky and require manual measurement recording, potentially generating intra- and interobserver error. To address these limitations, we tested the reliability, validity, and error rates of a novel device, the Portable Osteometric Device Version 1 (PODv1), which measures distance using laser sensors with time-of-flight technology. Forty-five volunteers measured four skeletal elements with the PODv1 and a PaleoTech osteometric board in three rounds. Comparison of tibia, humerus, and femur measurements with both devices showed no significant differences, although the maximum length of the ulna did differ, potentially because of observer confusion regarding the PODv1's user instructions for this element. Our results suggest that the PODv1 is a reliable, valid measurement device compared to traditional osteometric boards. Although both device types can produce calibration, transcription, and observer errors, the time-of-flight technology and the absence of manual recording built into the PODv1 may limit those errors. These advancements and their potential positive impacts on the accuracy of osteometric data collection may have far-reaching benefits for osteological, bioarchaeological, paleopathological, and forensic anthropological data collection.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.