用于比较评估电压源逆变器的实验测试性能:双电压源逆变器

M. Mangaraj, Jogeswara Sabat, Ajit Kumar Barisal
{"title":"用于比较评估电压源逆变器的实验测试性能:双电压源逆变器","authors":"M. Mangaraj, Jogeswara Sabat, Ajit Kumar Barisal","doi":"10.2478/jee-2024-0008","DOIUrl":null,"url":null,"abstract":"\n This article proposes an adaptive Kernel-Hebbian least mean square (KHLMS) controller for a dual voltage source inverter (VSI). The recommended topology consists of a distributed energy resource (DER) supported VSI called main VSI (MVSI) and split capacitor supported VSI termed as auxiliary VSI (AVSI). Both the MVSI and AVSI are used to serve the shunt compensation when DER is not integrated with MVSI. The DER scenario is considered to suppress the active power flow shortage in the utility grid. Here, optimal active power flow control (OAPFC) is managed by MVSI and shunt compensation is achieved by AVSI during DER operated mode. Hence, a dual VSI based distribution static compensator (DSTATCOM) facilitates the configuration merits such as reduction in system downtime cost, filter rating switching stress etc. Supremacy of both the neural network (NN) based controller and topology is presented by comparing VSI (called AVSI) in the context of harmonic reduction in source side, voltage balancing, power factor (PF) enhancement, better voltage regulation and OAPFC. The experimental results are obtained through field programmable gate array (FPGA) based hardware units which exhibit radical improvement in the power quality (PQ) conferring as per the international standard grid code (IEEE-519-2017).","PeriodicalId":508697,"journal":{"name":"Journal of Electrical Engineering","volume":"36 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental test performance for a comparative evaluation of a voltage source inverter: Dual voltage source inverter\",\"authors\":\"M. Mangaraj, Jogeswara Sabat, Ajit Kumar Barisal\",\"doi\":\"10.2478/jee-2024-0008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n This article proposes an adaptive Kernel-Hebbian least mean square (KHLMS) controller for a dual voltage source inverter (VSI). The recommended topology consists of a distributed energy resource (DER) supported VSI called main VSI (MVSI) and split capacitor supported VSI termed as auxiliary VSI (AVSI). Both the MVSI and AVSI are used to serve the shunt compensation when DER is not integrated with MVSI. The DER scenario is considered to suppress the active power flow shortage in the utility grid. Here, optimal active power flow control (OAPFC) is managed by MVSI and shunt compensation is achieved by AVSI during DER operated mode. Hence, a dual VSI based distribution static compensator (DSTATCOM) facilitates the configuration merits such as reduction in system downtime cost, filter rating switching stress etc. Supremacy of both the neural network (NN) based controller and topology is presented by comparing VSI (called AVSI) in the context of harmonic reduction in source side, voltage balancing, power factor (PF) enhancement, better voltage regulation and OAPFC. The experimental results are obtained through field programmable gate array (FPGA) based hardware units which exhibit radical improvement in the power quality (PQ) conferring as per the international standard grid code (IEEE-519-2017).\",\"PeriodicalId\":508697,\"journal\":{\"name\":\"Journal of Electrical Engineering\",\"volume\":\"36 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electrical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/jee-2024-0008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jee-2024-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文为双电压源逆变器(VSI)提出了一种自适应核-赫比最小均方(KHLMS)控制器。推荐的拓扑结构包括一个由分布式能源资源(DER)支持的 VSI,称为主 VSI(MVSI),以及由分路电容器支持的 VSI,称为辅助 VSI(AVSI)。当 DER 未与 MVSI 集成时,MVSI 和 AVSI 均用于并联补偿。DER 方案用于抑制公用电网的有功功率流短缺。在此,有功功率流控制(OAPFC)由 MVSI 管理,而并联补偿则由 AVSI 在 DER 运行模式下实现。因此,基于双 VSI 的配电静态补偿器(DSTATCOM)具有配置便利的优点,如降低系统停机成本、滤波器额定开关压力等。通过比较 VSI(称为 AVSI)在减少源侧谐波、电压平衡、提高功率因数 (PF)、改善电压调节和 OAPFC 方面的优势,介绍了基于神经网络 (NN) 的控制器和拓扑结构的优越性。实验结果是通过基于现场可编程门阵列(FPGA)的硬件单元获得的,这些单元按照国际标准电网规范(IEEE-519-2017)对电能质量(PQ)进行了彻底改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Experimental test performance for a comparative evaluation of a voltage source inverter: Dual voltage source inverter
This article proposes an adaptive Kernel-Hebbian least mean square (KHLMS) controller for a dual voltage source inverter (VSI). The recommended topology consists of a distributed energy resource (DER) supported VSI called main VSI (MVSI) and split capacitor supported VSI termed as auxiliary VSI (AVSI). Both the MVSI and AVSI are used to serve the shunt compensation when DER is not integrated with MVSI. The DER scenario is considered to suppress the active power flow shortage in the utility grid. Here, optimal active power flow control (OAPFC) is managed by MVSI and shunt compensation is achieved by AVSI during DER operated mode. Hence, a dual VSI based distribution static compensator (DSTATCOM) facilitates the configuration merits such as reduction in system downtime cost, filter rating switching stress etc. Supremacy of both the neural network (NN) based controller and topology is presented by comparing VSI (called AVSI) in the context of harmonic reduction in source side, voltage balancing, power factor (PF) enhancement, better voltage regulation and OAPFC. The experimental results are obtained through field programmable gate array (FPGA) based hardware units which exhibit radical improvement in the power quality (PQ) conferring as per the international standard grid code (IEEE-519-2017).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Area and energy optimized Hamming encoder and decoder for nano-communication High-performance MTM inspired two-port MIMO antenna structure for 5G/IoT applications Contribution to the determination of the effect of magnetic storms on the electric power transmission system Exploring and mitigating hybrid rank attack in RPL-based IoT networks Mutually coupled dual-stage RC feedback LNA for RF applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1