基于机构临床适应症的多相腹盆腔计算机断层扫描检查典型剂量值。

IF 1.4 4区 医学 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Diagnostic and interventional radiology Pub Date : 2024-02-20 DOI:10.4274/dir.2024.232551
Süleyman Filiz, Safiye Gürel, Kamil Gürel
{"title":"基于机构临床适应症的多相腹盆腔计算机断层扫描检查典型剂量值。","authors":"Süleyman Filiz, Safiye Gürel, Kamil Gürel","doi":"10.4274/dir.2024.232551","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Our study aimed to obtain clinical indication-based typical dose values and size-specific dose estimates (SSDEs) for multiphasic abdominopelvic computed tomography (CT) examinations and to review our data with published diagnostic reference levels (DRLs).</p><p><strong>Methods: </strong>In this retrospective study, multiphasic liver, kidney, pancreas, and mesenteric ischemia protocol CT scans performed at our center between January 2018 and December 2021 were analyzed. The clinical indications were hepatocellular carcinoma, renal cell carcinoma, pancreas adenocarcinoma, and mesenteric ischemia. The computed tomography dose index volume (CTDI<sub>vol</sub>) and dose-length product (DLP) values were recorded, and the SSDE and effective dose (ED) values were calculated. The water-equivalent diameter (Dw) value required for the SSDE calculation was measured using the automated calculation of the Dw program.</p><p><strong>Results: </strong>The total number of patients was 514, with 86 patients excluded from this study. The dose values were calculated for 426 patients (183 female and 243 male; 111 liver, 120 kidney, 85 pancreas, and 110 mesenteric). The median values for the CTDI<sub>vol</sub>, DLP, SSDE, and ED were 6.86 mGy, 683.02 mGy. cm, 8.75 mGy, and 10.45 mSv for the liver CT; 8.37 mGy, 908.37 mGy.cm, 10.37 mGy, and 13.89 mSv for the kidney CT; 7.82 mGy, 517.98 mGy.cm, 10.01 mGy, and 7.92 mSv for the pancreas CT; and 9.48 mGy, 983.68 mGy.cm, 12.78 mGy, and 13.86 mSv for the mesenteric CT, respectively. All dose values were lower than the published DRLs.</p><p><strong>Conclusion: </strong>The literature reveals large differences in the multiphasic abdominopelvic CT protocols, especially in the number of phases and scan length. This situation makes comparing dose values difficult. Dose studies revealing the protocol parameters in detail are needed so that institutions can compare and optimize their own protocols. Additionally, users should periodically check the dose values in their own institutions.</p>","PeriodicalId":11341,"journal":{"name":"Diagnostic and interventional radiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Institutional clinical indication-based typical dose values of multiphasic abdominopelvic computed tomography examinations.\",\"authors\":\"Süleyman Filiz, Safiye Gürel, Kamil Gürel\",\"doi\":\"10.4274/dir.2024.232551\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Our study aimed to obtain clinical indication-based typical dose values and size-specific dose estimates (SSDEs) for multiphasic abdominopelvic computed tomography (CT) examinations and to review our data with published diagnostic reference levels (DRLs).</p><p><strong>Methods: </strong>In this retrospective study, multiphasic liver, kidney, pancreas, and mesenteric ischemia protocol CT scans performed at our center between January 2018 and December 2021 were analyzed. The clinical indications were hepatocellular carcinoma, renal cell carcinoma, pancreas adenocarcinoma, and mesenteric ischemia. The computed tomography dose index volume (CTDI<sub>vol</sub>) and dose-length product (DLP) values were recorded, and the SSDE and effective dose (ED) values were calculated. The water-equivalent diameter (Dw) value required for the SSDE calculation was measured using the automated calculation of the Dw program.</p><p><strong>Results: </strong>The total number of patients was 514, with 86 patients excluded from this study. The dose values were calculated for 426 patients (183 female and 243 male; 111 liver, 120 kidney, 85 pancreas, and 110 mesenteric). The median values for the CTDI<sub>vol</sub>, DLP, SSDE, and ED were 6.86 mGy, 683.02 mGy. cm, 8.75 mGy, and 10.45 mSv for the liver CT; 8.37 mGy, 908.37 mGy.cm, 10.37 mGy, and 13.89 mSv for the kidney CT; 7.82 mGy, 517.98 mGy.cm, 10.01 mGy, and 7.92 mSv for the pancreas CT; and 9.48 mGy, 983.68 mGy.cm, 12.78 mGy, and 13.86 mSv for the mesenteric CT, respectively. All dose values were lower than the published DRLs.</p><p><strong>Conclusion: </strong>The literature reveals large differences in the multiphasic abdominopelvic CT protocols, especially in the number of phases and scan length. This situation makes comparing dose values difficult. Dose studies revealing the protocol parameters in detail are needed so that institutions can compare and optimize their own protocols. Additionally, users should periodically check the dose values in their own institutions.</p>\",\"PeriodicalId\":11341,\"journal\":{\"name\":\"Diagnostic and interventional radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and interventional radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4274/dir.2024.232551\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and interventional radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4274/dir.2024.232551","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

目的:我们的研究旨在获得基于临床适应症的多相腹盆腔计算机断层扫描(CT)检查的典型剂量值和特定尺寸剂量估计值(SSDE),并将我们的数据与已公布的诊断参考水平(DRL)进行对比:在这项回顾性研究中,我们分析了2018年1月至2021年12月期间在本中心进行的多相肝脏、肾脏、胰腺和肠系膜缺血方案CT扫描。临床适应症为肝细胞癌、肾细胞癌、胰腺腺癌和肠系膜缺血。记录了计算机断层扫描剂量指数体积(CTDIvol)和剂量-长度乘积(DLP)值,并计算了SSDE和有效剂量(ED)值。计算 SSDE 所需的水当量直径(Dw)值是通过 Dw 程序自动计算得出的:患者总数为 514 人,其中 86 人未纳入本研究。计算了 426 名患者(183 名女性和 243 名男性;111 名肝脏患者、120 名肾脏患者、85 名胰腺患者和 110 名肠系膜患者)的剂量值。肝脏 CT 的 CTDIvol、DLP、SSDE 和 ED 中值分别为 6.86 mGy、683.02 mGy.cm、8.75 mGy 和 10.45 mSv;肾脏 CT 的 CTDIvol、DLP、SSDE 和 ED 中值分别为 8.37 mGy、908.37 mGy.cm、10.37 mGy 和 13.89 mSv。肾脏 CT 分别为 8.37 mGy、908.37 mGy.cm、10.37 mGy 和 13.89 mSv;胰腺 CT 分别为 7.82 mGy、517.98 mGy.cm、10.01 mGy 和 7.92 mSv;肠系膜 CT 分别为 9.48 mGy、983.68 mGy.cm、12.78 mGy 和 13.86 mSv。所有剂量值均低于已公布的 DRL:文献显示,多相腹盆腔 CT 方案存在很大差异,尤其是在阶段数和扫描长度方面。这种情况使得比较剂量值变得困难。需要进行详细揭示方案参数的剂量研究,以便各机构比较和优化自己的方案。此外,用户应定期检查自己机构的剂量值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Institutional clinical indication-based typical dose values of multiphasic abdominopelvic computed tomography examinations.

Purpose: Our study aimed to obtain clinical indication-based typical dose values and size-specific dose estimates (SSDEs) for multiphasic abdominopelvic computed tomography (CT) examinations and to review our data with published diagnostic reference levels (DRLs).

Methods: In this retrospective study, multiphasic liver, kidney, pancreas, and mesenteric ischemia protocol CT scans performed at our center between January 2018 and December 2021 were analyzed. The clinical indications were hepatocellular carcinoma, renal cell carcinoma, pancreas adenocarcinoma, and mesenteric ischemia. The computed tomography dose index volume (CTDIvol) and dose-length product (DLP) values were recorded, and the SSDE and effective dose (ED) values were calculated. The water-equivalent diameter (Dw) value required for the SSDE calculation was measured using the automated calculation of the Dw program.

Results: The total number of patients was 514, with 86 patients excluded from this study. The dose values were calculated for 426 patients (183 female and 243 male; 111 liver, 120 kidney, 85 pancreas, and 110 mesenteric). The median values for the CTDIvol, DLP, SSDE, and ED were 6.86 mGy, 683.02 mGy. cm, 8.75 mGy, and 10.45 mSv for the liver CT; 8.37 mGy, 908.37 mGy.cm, 10.37 mGy, and 13.89 mSv for the kidney CT; 7.82 mGy, 517.98 mGy.cm, 10.01 mGy, and 7.92 mSv for the pancreas CT; and 9.48 mGy, 983.68 mGy.cm, 12.78 mGy, and 13.86 mSv for the mesenteric CT, respectively. All dose values were lower than the published DRLs.

Conclusion: The literature reveals large differences in the multiphasic abdominopelvic CT protocols, especially in the number of phases and scan length. This situation makes comparing dose values difficult. Dose studies revealing the protocol parameters in detail are needed so that institutions can compare and optimize their own protocols. Additionally, users should periodically check the dose values in their own institutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Diagnostic and interventional radiology
Diagnostic and interventional radiology Medicine-Radiology, Nuclear Medicine and Imaging
自引率
4.80%
发文量
0
期刊介绍: Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English. The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.
期刊最新文献
Diagnostic value of the flare sign in predicting extracapsular extension in metastatic axillary lymph nodes and nodal status on breast magnetic resonance imaging. Challenges associated with percutaneous nephrostomy in infants Correlation between computed tomography-based body composition parameters and hepatic venous pressure gradient in patients with cirrhosis: a systematic review and meta-analysis Experimental study of a canine model for a newly designed adjustable prefenestration aortic stent graft Pre-procedure 18F-FDG PET/CT imaging improves the performance of CT-guided transthoracic biopsy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1