Clara Monferrer-Adsuara, Lidia Remolí-Sargues, Catalina Navarro-Palop, Enrique Cervera-Taulet, Javier Montero-Hernández, Pascual Medina-Bessó, Verónica Castro-Navarro
{"title":"扫源光学相干断层血管造影自动黄斑血管密度的可重复性。","authors":"Clara Monferrer-Adsuara, Lidia Remolí-Sargues, Catalina Navarro-Palop, Enrique Cervera-Taulet, Javier Montero-Hernández, Pascual Medina-Bessó, Verónica Castro-Navarro","doi":"10.1177/11206721241233620","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Optical Coherence Tomography Angiography Ratio Analysis (OCTARA) is capable of visualizing inner and outer retinal vascular plexuses, choriocapillaris, and larger choroidal vasculature in vivo without contrast injection. The aim of this study was to assess the intrasession repeatability of automated vessel density measurements using Triton Swept-Source Optical Coherence Tomography Angiography (OCTA) innovative algorithm OCTARA in retinal and choroidal vasculature.</p><p><strong>Methods: </strong>To study population between 65-90 years old with no eye diseases. For each subject measurements were performed four times. The intraclass correlation coefficient and the coefficient of variation were calculated to analyze repeatability of the OCTARA automatically generated vessel density measurements.</p><p><strong>Results: </strong>A total of 35 eyes were included in the study. The intraclass correlation coefficient of the global vessel density in the superficial capillary plexus and the deep capillary plexus were 0.963 and 0.975, respectively, and the coefficient of variation were 5.4% and 4.4%, respectively. The intraclass correlation coefficient of the rest of the global measurements was indicative of good reliability with the exception of the deep choroid layer with an intraclass correlation coefficient of 0.6 indicative of moderate reliability.</p><p><strong>Conclusions: </strong>Our results proved excellent repeatability of automated vessel density measurements in the superficial and deep capillary plexus layers in our cohort using a OCTARA algorithm indicating that it may be a reliable diagnostic tool. It also showed good reliability in choriocapillary and mid choroid layer. These findings may be of value in assessing the significance of differences in capillary density measurements over time and across different settings.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Repeatability of swept-source optical coherence tomography angiography automated macular vessel density.\",\"authors\":\"Clara Monferrer-Adsuara, Lidia Remolí-Sargues, Catalina Navarro-Palop, Enrique Cervera-Taulet, Javier Montero-Hernández, Pascual Medina-Bessó, Verónica Castro-Navarro\",\"doi\":\"10.1177/11206721241233620\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Optical Coherence Tomography Angiography Ratio Analysis (OCTARA) is capable of visualizing inner and outer retinal vascular plexuses, choriocapillaris, and larger choroidal vasculature in vivo without contrast injection. The aim of this study was to assess the intrasession repeatability of automated vessel density measurements using Triton Swept-Source Optical Coherence Tomography Angiography (OCTA) innovative algorithm OCTARA in retinal and choroidal vasculature.</p><p><strong>Methods: </strong>To study population between 65-90 years old with no eye diseases. For each subject measurements were performed four times. The intraclass correlation coefficient and the coefficient of variation were calculated to analyze repeatability of the OCTARA automatically generated vessel density measurements.</p><p><strong>Results: </strong>A total of 35 eyes were included in the study. The intraclass correlation coefficient of the global vessel density in the superficial capillary plexus and the deep capillary plexus were 0.963 and 0.975, respectively, and the coefficient of variation were 5.4% and 4.4%, respectively. The intraclass correlation coefficient of the rest of the global measurements was indicative of good reliability with the exception of the deep choroid layer with an intraclass correlation coefficient of 0.6 indicative of moderate reliability.</p><p><strong>Conclusions: </strong>Our results proved excellent repeatability of automated vessel density measurements in the superficial and deep capillary plexus layers in our cohort using a OCTARA algorithm indicating that it may be a reliable diagnostic tool. It also showed good reliability in choriocapillary and mid choroid layer. These findings may be of value in assessing the significance of differences in capillary density measurements over time and across different settings.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241233620\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241233620","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Introduction: Optical Coherence Tomography Angiography Ratio Analysis (OCTARA) is capable of visualizing inner and outer retinal vascular plexuses, choriocapillaris, and larger choroidal vasculature in vivo without contrast injection. The aim of this study was to assess the intrasession repeatability of automated vessel density measurements using Triton Swept-Source Optical Coherence Tomography Angiography (OCTA) innovative algorithm OCTARA in retinal and choroidal vasculature.
Methods: To study population between 65-90 years old with no eye diseases. For each subject measurements were performed four times. The intraclass correlation coefficient and the coefficient of variation were calculated to analyze repeatability of the OCTARA automatically generated vessel density measurements.
Results: A total of 35 eyes were included in the study. The intraclass correlation coefficient of the global vessel density in the superficial capillary plexus and the deep capillary plexus were 0.963 and 0.975, respectively, and the coefficient of variation were 5.4% and 4.4%, respectively. The intraclass correlation coefficient of the rest of the global measurements was indicative of good reliability with the exception of the deep choroid layer with an intraclass correlation coefficient of 0.6 indicative of moderate reliability.
Conclusions: Our results proved excellent repeatability of automated vessel density measurements in the superficial and deep capillary plexus layers in our cohort using a OCTARA algorithm indicating that it may be a reliable diagnostic tool. It also showed good reliability in choriocapillary and mid choroid layer. These findings may be of value in assessing the significance of differences in capillary density measurements over time and across different settings.
期刊介绍:
The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.