Leon Pomberger, Lisa Tasch, Mats Lundström, Klemens Waser, Haidar Khalil, Martin Kronschläger, Nino Hirnschall, Matthias Bolz
{"title":"角膜病结果研究问卷德文版的评估。","authors":"Leon Pomberger, Lisa Tasch, Mats Lundström, Klemens Waser, Haidar Khalil, Martin Kronschläger, Nino Hirnschall, Matthias Bolz","doi":"10.1097/ICO.0000000000003506","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To translate, validate, and evaluate the psychometric properties of the German version of Keratoconus Outcomes Research Questionnaire (KORQ).</p><p><strong>Methods: </strong>This prospective study included 3 phases. In phase 1, the KORQ was translated in a standardized way; in phase 2, Rasch validation was performed; in phase 3, the validated questionnaire was evaluated in a separate patient cohort. All patients answered the German KORQ. Scheimpflug imaging (Pentacam) and optical coherence tomography scans (MS-39) were conducted. Corneal imaging measurements were correlated with patient-reported outcome measures.</p><p><strong>Results: </strong>After standardized translation, 100 patients self-administered the German KORQ. Rasch analysis was conducted for psychometric testing of the KORQ. Based on the results of the Rasch analysis, the original German version of the KORQ was modified and any items showing a misfit were excluded. This resulted in a new shortened version of the KORQ, which was evaluated in 30 patients. The revised German KORQ met the criteria of Rasch analysis and showed excellent internal consistency reliability and convergent validity. The correlation between the KORQ score and various clinical measurements was examined using Spearman correlation. A significant moderate correlation was observed between the D (r = 0.237; P = 0.006) and K max (r = 0.162; P = 0.065) values of Pentacam. Inverse correlations were observed for thinnest pachymetry measured with MS-39 (r = -0.167; P = 0.058) and best corrected visual acuity (r = -0.210; P = 0.016).</p><p><strong>Conclusions: </strong>The shortened German KORQ met the assumptions of the Rasch model and displayed satisfactory psychometric properties. The German KORQ could be adopted as a powerful patient-reported outcome measures tool for German-speaking patients with keratoconus in the future.</p>","PeriodicalId":10710,"journal":{"name":"Cornea","volume":" ","pages":"1493-1498"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the German Version of the Keratoconus Outcomes Research Questionnaire.\",\"authors\":\"Leon Pomberger, Lisa Tasch, Mats Lundström, Klemens Waser, Haidar Khalil, Martin Kronschläger, Nino Hirnschall, Matthias Bolz\",\"doi\":\"10.1097/ICO.0000000000003506\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To translate, validate, and evaluate the psychometric properties of the German version of Keratoconus Outcomes Research Questionnaire (KORQ).</p><p><strong>Methods: </strong>This prospective study included 3 phases. In phase 1, the KORQ was translated in a standardized way; in phase 2, Rasch validation was performed; in phase 3, the validated questionnaire was evaluated in a separate patient cohort. All patients answered the German KORQ. Scheimpflug imaging (Pentacam) and optical coherence tomography scans (MS-39) were conducted. Corneal imaging measurements were correlated with patient-reported outcome measures.</p><p><strong>Results: </strong>After standardized translation, 100 patients self-administered the German KORQ. Rasch analysis was conducted for psychometric testing of the KORQ. Based on the results of the Rasch analysis, the original German version of the KORQ was modified and any items showing a misfit were excluded. This resulted in a new shortened version of the KORQ, which was evaluated in 30 patients. The revised German KORQ met the criteria of Rasch analysis and showed excellent internal consistency reliability and convergent validity. The correlation between the KORQ score and various clinical measurements was examined using Spearman correlation. A significant moderate correlation was observed between the D (r = 0.237; P = 0.006) and K max (r = 0.162; P = 0.065) values of Pentacam. Inverse correlations were observed for thinnest pachymetry measured with MS-39 (r = -0.167; P = 0.058) and best corrected visual acuity (r = -0.210; P = 0.016).</p><p><strong>Conclusions: </strong>The shortened German KORQ met the assumptions of the Rasch model and displayed satisfactory psychometric properties. The German KORQ could be adopted as a powerful patient-reported outcome measures tool for German-speaking patients with keratoconus in the future.</p>\",\"PeriodicalId\":10710,\"journal\":{\"name\":\"Cornea\",\"volume\":\" \",\"pages\":\"1493-1498\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cornea\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICO.0000000000003506\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cornea","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICO.0000000000003506","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Evaluation of the German Version of the Keratoconus Outcomes Research Questionnaire.
Purpose: To translate, validate, and evaluate the psychometric properties of the German version of Keratoconus Outcomes Research Questionnaire (KORQ).
Methods: This prospective study included 3 phases. In phase 1, the KORQ was translated in a standardized way; in phase 2, Rasch validation was performed; in phase 3, the validated questionnaire was evaluated in a separate patient cohort. All patients answered the German KORQ. Scheimpflug imaging (Pentacam) and optical coherence tomography scans (MS-39) were conducted. Corneal imaging measurements were correlated with patient-reported outcome measures.
Results: After standardized translation, 100 patients self-administered the German KORQ. Rasch analysis was conducted for psychometric testing of the KORQ. Based on the results of the Rasch analysis, the original German version of the KORQ was modified and any items showing a misfit were excluded. This resulted in a new shortened version of the KORQ, which was evaluated in 30 patients. The revised German KORQ met the criteria of Rasch analysis and showed excellent internal consistency reliability and convergent validity. The correlation between the KORQ score and various clinical measurements was examined using Spearman correlation. A significant moderate correlation was observed between the D (r = 0.237; P = 0.006) and K max (r = 0.162; P = 0.065) values of Pentacam. Inverse correlations were observed for thinnest pachymetry measured with MS-39 (r = -0.167; P = 0.058) and best corrected visual acuity (r = -0.210; P = 0.016).
Conclusions: The shortened German KORQ met the assumptions of the Rasch model and displayed satisfactory psychometric properties. The German KORQ could be adopted as a powerful patient-reported outcome measures tool for German-speaking patients with keratoconus in the future.
期刊介绍:
For corneal specialists and for all general ophthalmologists with an interest in this exciting subspecialty, Cornea brings together the latest clinical and basic research on the cornea and the anterior segment of the eye. Each volume is peer-reviewed by Cornea''s board of world-renowned experts and fully indexed in archival format. Your subscription brings you the latest developments in your field and a growing library of valuable professional references.
Sponsored by The Cornea Society which was founded as the Castroviejo Cornea Society in 1975.