Kathryn Chadason, Christopher Root MD, Jess Boyle, Jonathan St. George MD, James Ducanto MD
{"title":"采用改良尸体技术模拟污染气道场景,对医疗服务提供者进行吸痰辅助喉镜检查和气道净化培训","authors":"Kathryn Chadason, Christopher Root MD, Jess Boyle, Jonathan St. George MD, James Ducanto MD","doi":"10.1002/aet2.10942","DOIUrl":null,"url":null,"abstract":"<p>Simulation training plays a vital role in modern medical education, fostering safe skill development. Task-trainer manikin and cadaveric airway management training (CAMT) offer realistic airway management practice. Simulation allows learners the opportunity to manage high-risk, low-frequency scenarios, including difficult airways and massive airway contamination, common in emergent airway management. The suction-assisted laryngoscopy and airway decontamination (SALAD) technique was developed to address massive airway contamination. This paper describes two methods to simulate massive airway contamination utilizing cadavers. We detail our techniques for both esophageal and nasopharyngeal delivery of simulated airway contaminant. Nasopharyngeal delivery was less invasive and required less time to set up. Utilizing cadavers to simulate massive airway contamination in CAMT provides learners with tools to manage airway complications effectively, enhancing readiness for complex airway challenges while promoting patient safety in clinical practice.</p>","PeriodicalId":37032,"journal":{"name":"AEM Education and Training","volume":"8 1","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modified cadaver technique to simulate contaminated airway scenarios to train medical providers in suction-assisted laryngoscopy and airway decontamination\",\"authors\":\"Kathryn Chadason, Christopher Root MD, Jess Boyle, Jonathan St. George MD, James Ducanto MD\",\"doi\":\"10.1002/aet2.10942\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Simulation training plays a vital role in modern medical education, fostering safe skill development. Task-trainer manikin and cadaveric airway management training (CAMT) offer realistic airway management practice. Simulation allows learners the opportunity to manage high-risk, low-frequency scenarios, including difficult airways and massive airway contamination, common in emergent airway management. The suction-assisted laryngoscopy and airway decontamination (SALAD) technique was developed to address massive airway contamination. This paper describes two methods to simulate massive airway contamination utilizing cadavers. We detail our techniques for both esophageal and nasopharyngeal delivery of simulated airway contaminant. Nasopharyngeal delivery was less invasive and required less time to set up. Utilizing cadavers to simulate massive airway contamination in CAMT provides learners with tools to manage airway complications effectively, enhancing readiness for complex airway challenges while promoting patient safety in clinical practice.</p>\",\"PeriodicalId\":37032,\"journal\":{\"name\":\"AEM Education and Training\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AEM Education and Training\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/aet2.10942\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"EDUCATION, SCIENTIFIC DISCIPLINES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AEM Education and Training","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/aet2.10942","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"EDUCATION, SCIENTIFIC DISCIPLINES","Score":null,"Total":0}
Modified cadaver technique to simulate contaminated airway scenarios to train medical providers in suction-assisted laryngoscopy and airway decontamination
Simulation training plays a vital role in modern medical education, fostering safe skill development. Task-trainer manikin and cadaveric airway management training (CAMT) offer realistic airway management practice. Simulation allows learners the opportunity to manage high-risk, low-frequency scenarios, including difficult airways and massive airway contamination, common in emergent airway management. The suction-assisted laryngoscopy and airway decontamination (SALAD) technique was developed to address massive airway contamination. This paper describes two methods to simulate massive airway contamination utilizing cadavers. We detail our techniques for both esophageal and nasopharyngeal delivery of simulated airway contaminant. Nasopharyngeal delivery was less invasive and required less time to set up. Utilizing cadavers to simulate massive airway contamination in CAMT provides learners with tools to manage airway complications effectively, enhancing readiness for complex airway challenges while promoting patient safety in clinical practice.