Tuong Trong Mai, Vinh Quang Nguyen, Phi Duong Nguyễn
{"title":"使用改良的 Merle d'Aubigné 肌腱转移法治疗无法恢复的桡神经麻痹。","authors":"Tuong Trong Mai, Vinh Quang Nguyen, Phi Duong Nguyễn","doi":"10.52965/001c.94033","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Irrecoverable radial nerve palsy (RNP) leads to the inability to extend the wrist and fingers and significant reduction in grip strength. The aim was to assess the outcomes of treating non-recovering motor RNP using the modified Merle d'Aubigné tendon transfer method.</p><p><strong>Materials and methods: </strong>A descriptive prospective study involved 33 patients between January 2017 and March 2019.</p><p><strong>Results: </strong>Males constituted the majority (32/33 cases, 97%). The ratio of radial nerve and posterior interosseous nerve injuries was nearly equivalent (16/17). The mean extension range of the wrist was 48.6° ± 14.9° during finger extension and 30.9° ± 14.4° during finger flexion. The mean flexion range of the wrist was 34.8° ± 15.8° during finger extension and 42.6° ± 14.8° during finger flexion. 93.9% of patients achieved full finger extension when the wrist joint was extended beyond 10°. The mean angulation range of the index finger was 55.3° ± 7.4°. The Kapanji score achieved was 8.4 ± 1.2. The achieved grip strength was 65.4% compared to the unaffected side. The surgery did not induce radial deviation deformities of the wrist joint. 32/33 patients were satisfied with the surgical outcomes. 31/33 patients returned to their previous professions. 93.9% of patients achieved very good and good results, while 6.1% achieved fair results.</p><p><strong>Conclusion: </strong>Treating irrecoverable radial nerve palsy using the modified Merle d'Aubigné tendon transfer method yields very good results. The utilization of the pronator teres for wrist extensor transfer and the flexor carpi radialis for finger extensor transfer is appropriate and contributes to limiting wrist joint radial deviation deformities. This modified technique has been researched and recommended by various authors worldwide.</p>","PeriodicalId":19669,"journal":{"name":"Orthopedic Reviews","volume":"16 ","pages":"94033"},"PeriodicalIF":1.4000,"publicationDate":"2024-02-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10891145/pdf/","citationCount":"0","resultStr":"{\"title\":\"TREATMENT OF IRRECOVERABLE RADIAL NERVE PALSY USING THE MODIFIED MERLE D'AUBIGNÉ TENDON TRANSFER METHOD.\",\"authors\":\"Tuong Trong Mai, Vinh Quang Nguyen, Phi Duong Nguyễn\",\"doi\":\"10.52965/001c.94033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Irrecoverable radial nerve palsy (RNP) leads to the inability to extend the wrist and fingers and significant reduction in grip strength. The aim was to assess the outcomes of treating non-recovering motor RNP using the modified Merle d'Aubigné tendon transfer method.</p><p><strong>Materials and methods: </strong>A descriptive prospective study involved 33 patients between January 2017 and March 2019.</p><p><strong>Results: </strong>Males constituted the majority (32/33 cases, 97%). The ratio of radial nerve and posterior interosseous nerve injuries was nearly equivalent (16/17). The mean extension range of the wrist was 48.6° ± 14.9° during finger extension and 30.9° ± 14.4° during finger flexion. The mean flexion range of the wrist was 34.8° ± 15.8° during finger extension and 42.6° ± 14.8° during finger flexion. 93.9% of patients achieved full finger extension when the wrist joint was extended beyond 10°. The mean angulation range of the index finger was 55.3° ± 7.4°. The Kapanji score achieved was 8.4 ± 1.2. The achieved grip strength was 65.4% compared to the unaffected side. The surgery did not induce radial deviation deformities of the wrist joint. 32/33 patients were satisfied with the surgical outcomes. 31/33 patients returned to their previous professions. 93.9% of patients achieved very good and good results, while 6.1% achieved fair results.</p><p><strong>Conclusion: </strong>Treating irrecoverable radial nerve palsy using the modified Merle d'Aubigné tendon transfer method yields very good results. The utilization of the pronator teres for wrist extensor transfer and the flexor carpi radialis for finger extensor transfer is appropriate and contributes to limiting wrist joint radial deviation deformities. This modified technique has been researched and recommended by various authors worldwide.</p>\",\"PeriodicalId\":19669,\"journal\":{\"name\":\"Orthopedic Reviews\",\"volume\":\"16 \",\"pages\":\"94033\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-02-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10891145/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthopedic Reviews\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52965/001c.94033\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52965/001c.94033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
TREATMENT OF IRRECOVERABLE RADIAL NERVE PALSY USING THE MODIFIED MERLE D'AUBIGNÉ TENDON TRANSFER METHOD.
Background: Irrecoverable radial nerve palsy (RNP) leads to the inability to extend the wrist and fingers and significant reduction in grip strength. The aim was to assess the outcomes of treating non-recovering motor RNP using the modified Merle d'Aubigné tendon transfer method.
Materials and methods: A descriptive prospective study involved 33 patients between January 2017 and March 2019.
Results: Males constituted the majority (32/33 cases, 97%). The ratio of radial nerve and posterior interosseous nerve injuries was nearly equivalent (16/17). The mean extension range of the wrist was 48.6° ± 14.9° during finger extension and 30.9° ± 14.4° during finger flexion. The mean flexion range of the wrist was 34.8° ± 15.8° during finger extension and 42.6° ± 14.8° during finger flexion. 93.9% of patients achieved full finger extension when the wrist joint was extended beyond 10°. The mean angulation range of the index finger was 55.3° ± 7.4°. The Kapanji score achieved was 8.4 ± 1.2. The achieved grip strength was 65.4% compared to the unaffected side. The surgery did not induce radial deviation deformities of the wrist joint. 32/33 patients were satisfied with the surgical outcomes. 31/33 patients returned to their previous professions. 93.9% of patients achieved very good and good results, while 6.1% achieved fair results.
Conclusion: Treating irrecoverable radial nerve palsy using the modified Merle d'Aubigné tendon transfer method yields very good results. The utilization of the pronator teres for wrist extensor transfer and the flexor carpi radialis for finger extensor transfer is appropriate and contributes to limiting wrist joint radial deviation deformities. This modified technique has been researched and recommended by various authors worldwide.
期刊介绍:
Orthopedic Reviews is an Open Access, online-only, peer-reviewed journal that considers articles concerned with any aspect of orthopedics, as well as diagnosis and treatment, trauma, surgical procedures, arthroscopy, sports medicine, rehabilitation, pediatric and geriatric orthopedics. All bone-related molecular and cell biology, genetics, pathophysiology and epidemiology papers are also welcome. The journal publishes original articles, brief reports, reviews and case reports of general interest.