基于有限元分析的各种下颌骨重建方法的比较。

IF 1.7 4区 医学 Q3 ENGINEERING, BIOMEDICAL Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Pub Date : 2024-04-01 Epub Date: 2024-02-28 DOI:10.1177/09544119241232282
Mehdi Parvan, Mohammad Saleh Khaghaninejad, Mohammad Taghi Karimi
{"title":"基于有限元分析的各种下颌骨重建方法的比较。","authors":"Mehdi Parvan, Mohammad Saleh Khaghaninejad, Mohammad Taghi Karimi","doi":"10.1177/09544119241232282","DOIUrl":null,"url":null,"abstract":"<p><p>The Mandible can be damaged by pathological factors, tumors, trauma, infection, and needs a surgical operation for reconstruction and restoring function. There are different methods for the reconstruction of mandible. Based on the surgical approach, primary reconstruction of mandible by reconstruction plate after resection is necessary for maintaining mandibular symmetric and esthetic of the lower third of the face. A finite element model of mandible and masticatory muscles was produced from a normal person (male with 35-year-old). The normal model was resected from the left sixth tooth to the second tooth. The pathological model was reconstructed in different conditions by macro plate. Different conditions were analyzed and compared based on bite force on right fifth tooth, stress developed on screws and macro plate. The finite element analysis results showed that maximum bite force and lower stress on screws were seen in the pathological model (condition 5) when one macro plate and six screws were inserted in the mid-body. The findings showed that the use of two macro plates causes lower stress on it than when we use one. Use of one macro plate and six screws is the best choice in mandibular immobilization which decrease the stress applied on bone and increase the bite force. Because of less stress developed on macro plates and screws, use of two macro plates or one macro plate in mid-body area are also preferred.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"423-429"},"PeriodicalIF":1.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The comparison between various methods of mandibular reconstruction based on finite element analysis.\",\"authors\":\"Mehdi Parvan, Mohammad Saleh Khaghaninejad, Mohammad Taghi Karimi\",\"doi\":\"10.1177/09544119241232282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The Mandible can be damaged by pathological factors, tumors, trauma, infection, and needs a surgical operation for reconstruction and restoring function. There are different methods for the reconstruction of mandible. Based on the surgical approach, primary reconstruction of mandible by reconstruction plate after resection is necessary for maintaining mandibular symmetric and esthetic of the lower third of the face. A finite element model of mandible and masticatory muscles was produced from a normal person (male with 35-year-old). The normal model was resected from the left sixth tooth to the second tooth. The pathological model was reconstructed in different conditions by macro plate. Different conditions were analyzed and compared based on bite force on right fifth tooth, stress developed on screws and macro plate. The finite element analysis results showed that maximum bite force and lower stress on screws were seen in the pathological model (condition 5) when one macro plate and six screws were inserted in the mid-body. The findings showed that the use of two macro plates causes lower stress on it than when we use one. Use of one macro plate and six screws is the best choice in mandibular immobilization which decrease the stress applied on bone and increase the bite force. Because of less stress developed on macro plates and screws, use of two macro plates or one macro plate in mid-body area are also preferred.</p>\",\"PeriodicalId\":20666,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"volume\":\" \",\"pages\":\"423-429\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09544119241232282\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119241232282","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

下颌骨可能因病理因素、肿瘤、外伤、感染而受损,需要通过外科手术来重建和恢复功能。下颌骨的重建有不同的方法。根据手术方法,为了保持下颌骨的对称性和面部下三分之一的美观,有必要在下颌骨切除后用重建板进行初级重建。我们从一个正常人(男性,35 岁)身上制作了下颌骨和咀嚼肌的有限元模型。正常模型从左侧第六颗牙齿到第二颗牙齿被切除。病理模型在不同条件下通过宏板重建。根据右侧第五颗牙齿的咬合力、螺钉和宏钢板上产生的应力,对不同情况进行了分析和比较。有限元分析结果显示,在病理模型(条件 5)中,当在牙体中部插入一块宏齿板和六颗螺钉时,咬合力最大,螺钉上的应力较小。研究结果表明,与使用一块宏钢板相比,使用两块宏钢板对其造成的应力更小。使用一块大钢板和六颗螺钉是下颌骨固定的最佳选择,这样可以减少骨头上的应力,增加咬合力。由于大钢板和螺钉所受的应力较小,在身体中部区域使用两块大钢板或一块大钢板也是首选。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The comparison between various methods of mandibular reconstruction based on finite element analysis.

The Mandible can be damaged by pathological factors, tumors, trauma, infection, and needs a surgical operation for reconstruction and restoring function. There are different methods for the reconstruction of mandible. Based on the surgical approach, primary reconstruction of mandible by reconstruction plate after resection is necessary for maintaining mandibular symmetric and esthetic of the lower third of the face. A finite element model of mandible and masticatory muscles was produced from a normal person (male with 35-year-old). The normal model was resected from the left sixth tooth to the second tooth. The pathological model was reconstructed in different conditions by macro plate. Different conditions were analyzed and compared based on bite force on right fifth tooth, stress developed on screws and macro plate. The finite element analysis results showed that maximum bite force and lower stress on screws were seen in the pathological model (condition 5) when one macro plate and six screws were inserted in the mid-body. The findings showed that the use of two macro plates causes lower stress on it than when we use one. Use of one macro plate and six screws is the best choice in mandibular immobilization which decrease the stress applied on bone and increase the bite force. Because of less stress developed on macro plates and screws, use of two macro plates or one macro plate in mid-body area are also preferred.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.60
自引率
5.60%
发文量
122
审稿时长
6 months
期刊介绍: The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.
期刊最新文献
Improving arterial stiffness prediction with machine learning utilizing hemodynamics and biomechanical features derived from phase contrast magnetic resonance imaging. Synthesis methods of Mg-based scaffolds and their applications in tissue engineering: A review. User experience of lower extremity exoskeletons and its improvement methodologies: A narrative review. A wavelet and local binary pattern-based feature descriptor for the detection of chronic infection through thoracic X-ray images. Optimization and control of robotic vertebral plate grinding: Predictive modeling, parameter optimization, and fuzzy control strategies for minimizing bone damage in laminectomy procedures.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1