John C Grotberg, Jon Greenberg, Mary Sullivan, Amit A Pawale, Kunal D Kotkar, Muhammad F Masood
{"title":"静脉-肺体外膜氧合治疗 COVID-19 ARDS 的生理优势:单中心经验。","authors":"John C Grotberg, Jon Greenberg, Mary Sullivan, Amit A Pawale, Kunal D Kotkar, Muhammad F Masood","doi":"10.1177/03913988241234543","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>A subset of patients with COVID-19 acute respiratory distress syndrome (ARDS) require extracorporeal membrane oxygenation (ECMO). Veno-pulmonary (VP) ECMO provides support to the right ventricle and decreased risk of recirculation.</p><p><strong>Methods: </strong>A retrospective analysis of patients with COVID-19 ARDS and VP ECMO was performed. Patients were separated into groups by indication (1) \"right ventricular (RV) failure,\" (2) \"refractory hypoxemia,\" and (3) \"recurrent suck-down events (SDEs).\" Pre- and post-configuration vasoactive inotropic scores (VIS), fraction of inspired oxygen (FIO<sub>2</sub>), and resolution of SDEs were reported. A 90-day mortality was computed for all groups. Patients were also compared to those who underwent conventional venovenous (VV) ECMO.</p><p><strong>Results: </strong>Forty-seven patients underwent VP ECMO configuration, 18 in group 1, 16 in group 2, and 8 in group 3. Ninety-day mortality was 66% for the entire cohort and was 77.8%, 81.3% and 37.5% for groups 1, 2, and 3, respectively. Mean VIS decreased in group 1 (8.3 vs 2.9, <i>p</i> = 0.005), while mean FIO<sub>2</sub> decreased in the group 2 and was sustained at 72 h (82.5% vs 52.5% and 47.5%, <i>p</i> < 0.001). Six of the eight (75%) of patients with recurrent SDEs had resolution of these events after configuration to VP ECMO. Patients with VP ECMO spent more days on ECMO (33 days compared to 18 days, <i>p</i> = 0.004) with no difference in mortality (66% compared to 55.1%, <i>p</i> = 0.28).</p><p><strong>Conclusion: </strong>VP ECMO in COVID-19 ARDS improves hemodynamics in patients with RV failure, improves oxygenation in patients with refractory hypoxemia and improves the frequency of SDEs.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"181-189"},"PeriodicalIF":1.4000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Physiologic benefits of veno-pulmonary extracorporeal membrane oxygenation for COVID-19 ARDS: A single center experience.\",\"authors\":\"John C Grotberg, Jon Greenberg, Mary Sullivan, Amit A Pawale, Kunal D Kotkar, Muhammad F Masood\",\"doi\":\"10.1177/03913988241234543\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>A subset of patients with COVID-19 acute respiratory distress syndrome (ARDS) require extracorporeal membrane oxygenation (ECMO). Veno-pulmonary (VP) ECMO provides support to the right ventricle and decreased risk of recirculation.</p><p><strong>Methods: </strong>A retrospective analysis of patients with COVID-19 ARDS and VP ECMO was performed. Patients were separated into groups by indication (1) \\\"right ventricular (RV) failure,\\\" (2) \\\"refractory hypoxemia,\\\" and (3) \\\"recurrent suck-down events (SDEs).\\\" Pre- and post-configuration vasoactive inotropic scores (VIS), fraction of inspired oxygen (FIO<sub>2</sub>), and resolution of SDEs were reported. A 90-day mortality was computed for all groups. Patients were also compared to those who underwent conventional venovenous (VV) ECMO.</p><p><strong>Results: </strong>Forty-seven patients underwent VP ECMO configuration, 18 in group 1, 16 in group 2, and 8 in group 3. Ninety-day mortality was 66% for the entire cohort and was 77.8%, 81.3% and 37.5% for groups 1, 2, and 3, respectively. Mean VIS decreased in group 1 (8.3 vs 2.9, <i>p</i> = 0.005), while mean FIO<sub>2</sub> decreased in the group 2 and was sustained at 72 h (82.5% vs 52.5% and 47.5%, <i>p</i> < 0.001). Six of the eight (75%) of patients with recurrent SDEs had resolution of these events after configuration to VP ECMO. Patients with VP ECMO spent more days on ECMO (33 days compared to 18 days, <i>p</i> = 0.004) with no difference in mortality (66% compared to 55.1%, <i>p</i> = 0.28).</p><p><strong>Conclusion: </strong>VP ECMO in COVID-19 ARDS improves hemodynamics in patients with RV failure, improves oxygenation in patients with refractory hypoxemia and improves the frequency of SDEs.</p>\",\"PeriodicalId\":13932,\"journal\":{\"name\":\"International Journal of Artificial Organs\",\"volume\":\" \",\"pages\":\"181-189\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/03913988241234543\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/28 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241234543","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Physiologic benefits of veno-pulmonary extracorporeal membrane oxygenation for COVID-19 ARDS: A single center experience.
Background: A subset of patients with COVID-19 acute respiratory distress syndrome (ARDS) require extracorporeal membrane oxygenation (ECMO). Veno-pulmonary (VP) ECMO provides support to the right ventricle and decreased risk of recirculation.
Methods: A retrospective analysis of patients with COVID-19 ARDS and VP ECMO was performed. Patients were separated into groups by indication (1) "right ventricular (RV) failure," (2) "refractory hypoxemia," and (3) "recurrent suck-down events (SDEs)." Pre- and post-configuration vasoactive inotropic scores (VIS), fraction of inspired oxygen (FIO2), and resolution of SDEs were reported. A 90-day mortality was computed for all groups. Patients were also compared to those who underwent conventional venovenous (VV) ECMO.
Results: Forty-seven patients underwent VP ECMO configuration, 18 in group 1, 16 in group 2, and 8 in group 3. Ninety-day mortality was 66% for the entire cohort and was 77.8%, 81.3% and 37.5% for groups 1, 2, and 3, respectively. Mean VIS decreased in group 1 (8.3 vs 2.9, p = 0.005), while mean FIO2 decreased in the group 2 and was sustained at 72 h (82.5% vs 52.5% and 47.5%, p < 0.001). Six of the eight (75%) of patients with recurrent SDEs had resolution of these events after configuration to VP ECMO. Patients with VP ECMO spent more days on ECMO (33 days compared to 18 days, p = 0.004) with no difference in mortality (66% compared to 55.1%, p = 0.28).
Conclusion: VP ECMO in COVID-19 ARDS improves hemodynamics in patients with RV failure, improves oxygenation in patients with refractory hypoxemia and improves the frequency of SDEs.
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.