{"title":"[移除卡住的导管后钙化的纤维蛋白鞘:病例报告和文献综述]。","authors":"Marco Taurisano, Andrea Mancini, Filomena D'elia, Giuseppe Gernone, Cosma Cortese","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The prevalence of central venous catheters (CVC) in hemodialysis patients is around 20-30%. In this scenario, complications related to the use of the CVC are commonly observed, requiring active management by nephrologists. These include infectious complications as well as those related to CVC malfunction. Among the latter, the formation of a fibrin sheath around the catheter linked to foreign body reaction could cause CVC malfunction in various ways. Even after the removal of the catheter, the fibrin sheath can remain inside the vascular lumen (ghost fibrin sheath) and rarely undergo calcification. We describe the clinical case of a hemodialysis patient who, following the removal of a malfunctioning, stuck CVC, presented a calcified tubular structure in the lumen of the superior vena cava, diagnosed as calcified fibrin sheath (CFS). This rare occurrence, described in the literature in 8 other cases, although rare, is certainly underdiagnosed and can lead to complications such as sepsis resulting from CFS, pulmonary embolisms, and vascular thrombosis. Therapeutic approaches should be considered only in symptomatic cases and involve an invasive surgical approach.</p>","PeriodicalId":12553,"journal":{"name":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Calcified Fibrin Sheath After Stuck Catheter Removal: Case Report and Literature Review].\",\"authors\":\"Marco Taurisano, Andrea Mancini, Filomena D'elia, Giuseppe Gernone, Cosma Cortese\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The prevalence of central venous catheters (CVC) in hemodialysis patients is around 20-30%. In this scenario, complications related to the use of the CVC are commonly observed, requiring active management by nephrologists. These include infectious complications as well as those related to CVC malfunction. Among the latter, the formation of a fibrin sheath around the catheter linked to foreign body reaction could cause CVC malfunction in various ways. Even after the removal of the catheter, the fibrin sheath can remain inside the vascular lumen (ghost fibrin sheath) and rarely undergo calcification. We describe the clinical case of a hemodialysis patient who, following the removal of a malfunctioning, stuck CVC, presented a calcified tubular structure in the lumen of the superior vena cava, diagnosed as calcified fibrin sheath (CFS). This rare occurrence, described in the literature in 8 other cases, although rare, is certainly underdiagnosed and can lead to complications such as sepsis resulting from CFS, pulmonary embolisms, and vascular thrombosis. Therapeutic approaches should be considered only in symptomatic cases and involve an invasive surgical approach.</p>\",\"PeriodicalId\":12553,\"journal\":{\"name\":\"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

血液透析患者使用中心静脉导管(CVC)的比例约为 20-30%。在这种情况下,与使用 CVC 相关的并发症很常见,需要肾科医生积极处理。这些并发症包括感染性并发症以及与 CVC 故障有关的并发症。其中,与异物反应有关的导管周围纤维蛋白鞘的形成会以各种方式导致 CVC 故障。即使在移除导管后,纤维蛋白鞘仍可能留在血管腔内(幽灵纤维蛋白鞘),而且很少发生钙化。我们描述了一例血液透析患者的临床病例,该患者在拔除发生故障的卡住的 CVC 后,上腔静脉管腔内出现了钙化的管状结构,被诊断为钙化纤维蛋白鞘(CFS)。这种罕见的情况在文献中还描述过 8 例,虽然罕见,但肯定诊断不足,可能导致并发症,如 CFS 引起的败血症、肺栓塞和血管血栓。只有在有症状的病例中才应考虑治疗方法,并采用侵入性手术方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Calcified Fibrin Sheath After Stuck Catheter Removal: Case Report and Literature Review].

The prevalence of central venous catheters (CVC) in hemodialysis patients is around 20-30%. In this scenario, complications related to the use of the CVC are commonly observed, requiring active management by nephrologists. These include infectious complications as well as those related to CVC malfunction. Among the latter, the formation of a fibrin sheath around the catheter linked to foreign body reaction could cause CVC malfunction in various ways. Even after the removal of the catheter, the fibrin sheath can remain inside the vascular lumen (ghost fibrin sheath) and rarely undergo calcification. We describe the clinical case of a hemodialysis patient who, following the removal of a malfunctioning, stuck CVC, presented a calcified tubular structure in the lumen of the superior vena cava, diagnosed as calcified fibrin sheath (CFS). This rare occurrence, described in the literature in 8 other cases, although rare, is certainly underdiagnosed and can lead to complications such as sepsis resulting from CFS, pulmonary embolisms, and vascular thrombosis. Therapeutic approaches should be considered only in symptomatic cases and involve an invasive surgical approach.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
62
期刊介绍: Il Giornale Italiano di Nefrologia (GIN) è la rivista di educazione continua della Società Italiana di Nefrologia SIN ed è pubblicato bimestralmente. E" il più autorevole organo di informazione nefrologia disponibile a livello nazionale. Il giornale Italiano di Nefrologia offre la più aggiornata informazione medico-scientifica rivolta al nefrologo sotto forma di rassegne, casi clinici e articoli finalizzati all’Educazione Continua in Medicina, oltre ai notiziari ed agli atti dei congressi di questa prestigiosa Società Scientifica
期刊最新文献
[ANCA-Associated Glomerulonephritis Following SARS-CoV2 Infection: A Case Report]. [Governo clinico in nefrologia: organizzazione e sviluppo della dialisi peritoneale]. [Hypotension and Generalized Edema Due to Plasma Leakage: A Case Report]. [Reactive Perforating Collagenosis in Hemodialysis Patients]. [Survey and Intervention Tools for Burnout in Dialysis Healthcare Staff].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1