利用离子注入金属标准品对二次离子质谱测量进行定量

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-02-29 DOI:10.1002/sia.7298
Guiomar Delgado Soria, María González, Miguel Luis Crespillo, Jesús Sánchez Prieto, Gastón García
{"title":"利用离子注入金属标准品对二次离子质谱测量进行定量","authors":"Guiomar Delgado Soria, María González, Miguel Luis Crespillo, Jesús Sánchez Prieto, Gastón García","doi":"10.1002/sia.7298","DOIUrl":null,"url":null,"abstract":"This research addresses an analytical methodology to quantify elements of interest in fusion‐relevant materials using secondary ion mass spectrometry (SIMS). For this purpose, internal standards have been fabricated by ion implantation to avoid the well‐known matrix effect of this technique. In particular, chromium has been implanted at an energy of 12 MeV using two fluences in high‐purity iron and tungsten matrices together with Si control substrates. The latter were applied to determine the Cr concentration implanted through experimental and semiempirical methods. Specifically, the IBA technique Rutherford backscattering spectrometry (RBS) provided the quantitative results being 3.1 × 10<jats:sup>19</jats:sup> at/cm<jats:sup>3</jats:sup> and 1.6 × 10<jats:sup>19</jats:sup> at/cm<jats:sup>3</jats:sup> for the high and low dose, respectively. The SIMS depth profiles of Cr for the Fe and W matrices established an ion implantation depth close to 2 μm on both substrates in agreement with the calculations previously performed by Stopping and Range of Ions in Matter (SRIM) simulations. Correlation between the integration of SIMS profiles and known concentrations of the implanted ion resulted in the calibration curve for each matrix, obtaining the SIMS quantification approach by means of this relative sensitivity factor (RSF). Additionally, a cross‐check of the method by comparing commercial Fe‐Cr alloys with the Cr‐implanted Fe matrices of the present study pointed out the need to produce standards with higher chromium concentrations.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantification of secondary ion mass spectrometry measurements by using ion‐implanted metallic standards\",\"authors\":\"Guiomar Delgado Soria, María González, Miguel Luis Crespillo, Jesús Sánchez Prieto, Gastón García\",\"doi\":\"10.1002/sia.7298\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This research addresses an analytical methodology to quantify elements of interest in fusion‐relevant materials using secondary ion mass spectrometry (SIMS). For this purpose, internal standards have been fabricated by ion implantation to avoid the well‐known matrix effect of this technique. In particular, chromium has been implanted at an energy of 12 MeV using two fluences in high‐purity iron and tungsten matrices together with Si control substrates. The latter were applied to determine the Cr concentration implanted through experimental and semiempirical methods. Specifically, the IBA technique Rutherford backscattering spectrometry (RBS) provided the quantitative results being 3.1 × 10<jats:sup>19</jats:sup> at/cm<jats:sup>3</jats:sup> and 1.6 × 10<jats:sup>19</jats:sup> at/cm<jats:sup>3</jats:sup> for the high and low dose, respectively. The SIMS depth profiles of Cr for the Fe and W matrices established an ion implantation depth close to 2 μm on both substrates in agreement with the calculations previously performed by Stopping and Range of Ions in Matter (SRIM) simulations. Correlation between the integration of SIMS profiles and known concentrations of the implanted ion resulted in the calibration curve for each matrix, obtaining the SIMS quantification approach by means of this relative sensitivity factor (RSF). Additionally, a cross‐check of the method by comparing commercial Fe‐Cr alloys with the Cr‐implanted Fe matrices of the present study pointed out the need to produce standards with higher chromium concentrations.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1002/sia.7298\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1002/sia.7298","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究采用二次离子质谱(SIMS)分析方法对核聚变相关材料中的相关元素进行定量分析。为此,通过离子注入法制作了内部标准,以避免该技术众所周知的基质效应。其中,铬是以 12 MeV 的能量植入高纯度的铁和钨基质以及硅控制基质中的。后者应用实验和半经验方法确定植入的铬浓度。具体来说,IBA 技术卢瑟福背散射光谱法(RBS)提供了定量结果,高剂量和低剂量分别为 3.1 × 1019 at/cm3 和 1.6 × 1019 at/cm3。铁基质和瓦基质中铬的 SIMS 深度剖面图显示,两种基质上的离子注入深度均接近 2 μm,这与之前通过物质中的离子停止和范围(SRIM)模拟进行的计算结果一致。SIMS 曲线的整合与植入离子的已知浓度之间的相关性导致了每种基质的校准曲线,通过这种相对灵敏度系数(RSF)获得了 SIMS 定量方法。此外,通过将商用铁铬合金与本研究中的铬植入铁基质进行比较,对该方法进行了交叉检验,结果表明需要生产铬浓度更高的标准物质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quantification of secondary ion mass spectrometry measurements by using ion‐implanted metallic standards
This research addresses an analytical methodology to quantify elements of interest in fusion‐relevant materials using secondary ion mass spectrometry (SIMS). For this purpose, internal standards have been fabricated by ion implantation to avoid the well‐known matrix effect of this technique. In particular, chromium has been implanted at an energy of 12 MeV using two fluences in high‐purity iron and tungsten matrices together with Si control substrates. The latter were applied to determine the Cr concentration implanted through experimental and semiempirical methods. Specifically, the IBA technique Rutherford backscattering spectrometry (RBS) provided the quantitative results being 3.1 × 1019 at/cm3 and 1.6 × 1019 at/cm3 for the high and low dose, respectively. The SIMS depth profiles of Cr for the Fe and W matrices established an ion implantation depth close to 2 μm on both substrates in agreement with the calculations previously performed by Stopping and Range of Ions in Matter (SRIM) simulations. Correlation between the integration of SIMS profiles and known concentrations of the implanted ion resulted in the calibration curve for each matrix, obtaining the SIMS quantification approach by means of this relative sensitivity factor (RSF). Additionally, a cross‐check of the method by comparing commercial Fe‐Cr alloys with the Cr‐implanted Fe matrices of the present study pointed out the need to produce standards with higher chromium concentrations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Management of Cholesteatoma: Hearing Rehabilitation. Congenital Cholesteatoma. Evaluation of Cholesteatoma. Management of Cholesteatoma: Extension Beyond Middle Ear/Mastoid. Recidivism and Recurrence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1