PAO 后髋臼矫正的维持:一项比较不锈钢螺钉和钛螺钉的多中心研究

IF 1.4 4区 医学 Q3 ORTHOPEDICS Journal of Hip Preservation Surgery Pub Date : 2024-02-29 DOI:10.1093/jhps/hnae008
Lei Zhao, Molly Uchtman, Alexander Aretakis, Courtney Selberg, James J McCarthy, Patrick W Whitlock
{"title":"PAO 后髋臼矫正的维持:一项比较不锈钢螺钉和钛螺钉的多中心研究","authors":"Lei Zhao, Molly Uchtman, Alexander Aretakis, Courtney Selberg, James J McCarthy, Patrick W Whitlock","doi":"10.1093/jhps/hnae008","DOIUrl":null,"url":null,"abstract":"Stainless-steel screws are commonly used for fragment fixation during periacetabular osteotomy (PAO) at our institutions. Titanium is reserved for patients with documented nickel allergies. Titanium screws possess a significantly lower Young’s modulus than stainless steel and, therefore, potentially less resistance to physiologic loading. Thus, we hypothesized that the use of titanium screws might be associated with changes in acetabular correction prior to healing. The aim of this study was to compare the maintenance of acetabular correction following PAO using stainless-steel or titanium screws. A documented nickel allergy was confirmed with an allergy specialist. Patients’ age at surgery, gender and BMI were collected. The lateral center–edge angle of Wiberg (LCEA), medial center–edge angle (MCEA), anterior wall index (AWI), posterior wall index (PWI) and Tönnis angle were measured. The delta value for radiographic parameters was calculated as the difference between values immediately post-operation and at 6 months post-operation. Only age at surgery (P < 0.001) and the pre-operative LCEA (P = 0.013) were significantly different between groups (Tables I and II). The remaining pre- and post-operative radiological measurements were similar (Table II). Comparison of delta values at 6 months follow-up indicated no significant differences between screw types (Table III). No patients in the titanium group had a trans-iliac retrograde screw included in their construct (P = 0.003). All patients healed from their osteotomies. The use of titanium screws in patients with an allergy to nickel was not associated with differences in acetabular correction or the rate of osseous union rates despite its lower inherent mechanical properties.","PeriodicalId":48583,"journal":{"name":"Journal of Hip Preservation Surgery","volume":"26 1","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Maintenance of acetabular correction following PAO: a multicenter study comparing stainless-steel and titanium screws\",\"authors\":\"Lei Zhao, Molly Uchtman, Alexander Aretakis, Courtney Selberg, James J McCarthy, Patrick W Whitlock\",\"doi\":\"10.1093/jhps/hnae008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Stainless-steel screws are commonly used for fragment fixation during periacetabular osteotomy (PAO) at our institutions. Titanium is reserved for patients with documented nickel allergies. Titanium screws possess a significantly lower Young’s modulus than stainless steel and, therefore, potentially less resistance to physiologic loading. Thus, we hypothesized that the use of titanium screws might be associated with changes in acetabular correction prior to healing. The aim of this study was to compare the maintenance of acetabular correction following PAO using stainless-steel or titanium screws. A documented nickel allergy was confirmed with an allergy specialist. Patients’ age at surgery, gender and BMI were collected. The lateral center–edge angle of Wiberg (LCEA), medial center–edge angle (MCEA), anterior wall index (AWI), posterior wall index (PWI) and Tönnis angle were measured. The delta value for radiographic parameters was calculated as the difference between values immediately post-operation and at 6 months post-operation. Only age at surgery (P < 0.001) and the pre-operative LCEA (P = 0.013) were significantly different between groups (Tables I and II). The remaining pre- and post-operative radiological measurements were similar (Table II). Comparison of delta values at 6 months follow-up indicated no significant differences between screw types (Table III). No patients in the titanium group had a trans-iliac retrograde screw included in their construct (P = 0.003). All patients healed from their osteotomies. The use of titanium screws in patients with an allergy to nickel was not associated with differences in acetabular correction or the rate of osseous union rates despite its lower inherent mechanical properties.\",\"PeriodicalId\":48583,\"journal\":{\"name\":\"Journal of Hip Preservation Surgery\",\"volume\":\"26 1\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-02-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hip Preservation Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/jhps/hnae008\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hip Preservation Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jhps/hnae008","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

在我们的机构中,不锈钢螺钉通常用于髋臼周围截骨术(PAO)中的碎片固定。有镍过敏记录的患者才使用钛。钛螺钉的杨氏模量明显低于不锈钢,因此可能对生理负荷的抵抗力较弱。因此,我们假设钛螺钉的使用可能与愈合前髋臼矫正的变化有关。本研究的目的是比较使用不锈钢或钛螺钉进行 PAO 后髋臼矫正的维持情况。经过敏专科医生确认,患者对镍过敏。收集了患者的手术年龄、性别和体重指数。测量了 Wiberg 外侧中心边缘角(LCEA)、内侧中心边缘角(MCEA)、前壁指数(AWI)、后壁指数(PWI)和 Tönnis 角。放射学参数的 delta 值按术后即刻值与术后 6 个月值之差计算。只有手术年龄(P < 0.001)和术前 LCEA(P = 0.013)在组间存在显著差异(表一和表二)。其余术前和术后放射学测量结果相似(表二)。随访 6 个月时的 delta 值比较显示,不同螺钉类型之间无明显差异(表 III)。钛组中没有患者的构造中包含经髂骨逆行螺钉(P = 0.003)。所有患者的截骨手术均已痊愈。对镍过敏的患者使用钛螺钉与髋臼矫正或骨结合率的差异无关,尽管钛螺钉的固有机械性能较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Maintenance of acetabular correction following PAO: a multicenter study comparing stainless-steel and titanium screws
Stainless-steel screws are commonly used for fragment fixation during periacetabular osteotomy (PAO) at our institutions. Titanium is reserved for patients with documented nickel allergies. Titanium screws possess a significantly lower Young’s modulus than stainless steel and, therefore, potentially less resistance to physiologic loading. Thus, we hypothesized that the use of titanium screws might be associated with changes in acetabular correction prior to healing. The aim of this study was to compare the maintenance of acetabular correction following PAO using stainless-steel or titanium screws. A documented nickel allergy was confirmed with an allergy specialist. Patients’ age at surgery, gender and BMI were collected. The lateral center–edge angle of Wiberg (LCEA), medial center–edge angle (MCEA), anterior wall index (AWI), posterior wall index (PWI) and Tönnis angle were measured. The delta value for radiographic parameters was calculated as the difference between values immediately post-operation and at 6 months post-operation. Only age at surgery (P < 0.001) and the pre-operative LCEA (P = 0.013) were significantly different between groups (Tables I and II). The remaining pre- and post-operative radiological measurements were similar (Table II). Comparison of delta values at 6 months follow-up indicated no significant differences between screw types (Table III). No patients in the titanium group had a trans-iliac retrograde screw included in their construct (P = 0.003). All patients healed from their osteotomies. The use of titanium screws in patients with an allergy to nickel was not associated with differences in acetabular correction or the rate of osseous union rates despite its lower inherent mechanical properties.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
20.00%
发文量
45
审稿时长
12 weeks
期刊最新文献
Is core decompression and bone marrow concentrate with demineralized bone matrix and platelet-rich fibrin suitable for treating femoral head osteonecrosis? Victorian Institute of Sport Assessment questionnaire specifically tailored for greater trochanteric pain syndrome for the Dutch population Self-reported preoperative anxiety and depression associated with worse patient-reported outcomes for periacetabular osteotomy and hip arthroscopy surgery Comparing outcomes of hip arthroscopy and periacetabular osteotomy for the treatment of borderline hip dysplasia: a systematic review Hip dysplasia-the Bernese contribution continues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1