更安全地阻断内收肌管的血管内收肌膜新见解。

IF 3.4 3区 医学 Q2 CLINICAL NEUROLOGY Korean Journal of Pain Pub Date : 2024-04-01 Epub Date: 2024-03-04 DOI:10.3344/kjp.23292
Yanguk Heo, Miyoung Yang, Sung Min Nam, Hyun Seung Lee, Yeon-Dong Kim, Hyung-Sun Won
{"title":"更安全地阻断内收肌管的血管内收肌膜新见解。","authors":"Yanguk Heo, Miyoung Yang, Sung Min Nam, Hyun Seung Lee, Yeon-Dong Kim, Hyung-Sun Won","doi":"10.3344/kjp.23292","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB).</p><p><strong>Methods: </strong>: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume.</p><p><strong>Results: </strong>: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery.</p><p><strong>Conclusions: </strong>: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.</p>","PeriodicalId":56252,"journal":{"name":"Korean Journal of Pain","volume":" ","pages":"132-140"},"PeriodicalIF":3.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10985484/pdf/","citationCount":"0","resultStr":"{\"title\":\"New insight into the vasto-adductor membrane for safer adductor canal blockade.\",\"authors\":\"Yanguk Heo, Miyoung Yang, Sung Min Nam, Hyun Seung Lee, Yeon-Dong Kim, Hyung-Sun Won\",\"doi\":\"10.3344/kjp.23292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB).</p><p><strong>Methods: </strong>: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume.</p><p><strong>Results: </strong>: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery.</p><p><strong>Conclusions: </strong>: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.</p>\",\"PeriodicalId\":56252,\"journal\":{\"name\":\"Korean Journal of Pain\",\"volume\":\" \",\"pages\":\"132-140\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10985484/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Pain\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3344/kjp.23292\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Pain","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3344/kjp.23292","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景: :本研究旨在确定准确的解剖标志和理想的注射量,以实现安全的内收肌管道阻滞(ACB):方法:研究人员使用了 25 具经防腐处理的韩国成年尸体的 50 条大腿。测量基线为髂前上棘与髌底中点的连线。所有目标点的测量都与基线垂直。使用超声波(US)观察尸体的相关结构,并在活人身上进行确认。在 US 引导下注射染料以确定理想体积:股骨三角区的顶点距基线上的 ASIS 远端为 25.3 ± 2.2 厘米,垂直于该点为 5.3 ± 1.0 厘米。在基线上,股外侧膜(VAM)上缘的中点距离ASIS远端为(27.4 ± 2.0)厘米,与该点的垂直距离为(5.0 ± 1.1)厘米。内收肌膜呈梯形,在内侧大肌内侧边缘和外侧大肌外侧边缘之间作为一条肌腱相连。在 70% 的标本中,通往内阔肌的神经在 VAM 上缘近端穿透肌肉。在 US 上,VAM 表现为连接内阔肌和大圆肌的高回声区,位于腓肠肌和股动脉之间:结论:在进行 ACB 时,确认 VAM 这一关键地标是有益的。建议在 VAM 上缘下方斜向插入针头,注射 5 mL 即可。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
New insight into the vasto-adductor membrane for safer adductor canal blockade.

Background: : This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB).

Methods: : Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume.

Results: : The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery.

Conclusions: : Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Pain
Korean Journal of Pain Medicine-Anesthesiology and Pain Medicine
CiteScore
5.40
自引率
7.10%
发文量
57
审稿时长
16 weeks
期刊介绍: Korean Journal of Pain (Korean J Pain, KJP) is the official journal of the Korean Pain Society, founded in 1986. It has been published since 1988. It publishes peer reviewed original articles related to all aspects of pain, including clinical and basic research, patient care, education, and health policy. It has been published quarterly in English since 2009 (on the first day of January, April, July, and October). In addition, it has also become the official journal of the International Spinal Pain Society since 2016. The mission of the Journal is to improve the care of patients in pain by providing a forum for clinical researchers, basic scientists, clinicians, and other health professionals. The circulation number per issue is 50.
期刊最新文献
Ultrasound-guided pain management: pros, cons, and benefits for the Philippines. Retraction: Comparison of the efficacy of genicular nerve phenol neurolysis and radiofrequency ablation for pain management in patients with knee osteoarthritis. A critical factor in resistant piriformis syndrome cases: awareness of sacrotuberous ligament pain. Effect of ultrasound-guided ilioinguinal-iliohypogastric nerve block on chronic pain in patients undergoing open inguinal hernia surgery under spinal anesthesia: a randomized double-blind study. Ultrasound-guided transoral pterygopalatine fossa block: cadaveric elaboration of a novel technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1