用于复杂髋关节翻修的模块化翻修系统:病例系列。

IF 0.8 Q4 SURGERY Surgical technology international Pub Date : 2024-07-15 Epub Date: 2024-03-01 DOI:10.52198/24.STI.44.OS1757
Daniel Hameed, Brittany Oster, Bryan D Springer, Arthur L Malkani, Michael A Mont
{"title":"用于复杂髋关节翻修的模块化翻修系统:病例系列。","authors":"Daniel Hameed, Brittany Oster, Bryan D Springer, Arthur L Malkani, Michael A Mont","doi":"10.52198/24.STI.44.OS1757","DOIUrl":null,"url":null,"abstract":"<p><p>Revision total hip arthroplasty (THA) is a procedure with many challenges, especially when patients exhibit femoral bone defects. The causes of these defects vary, ranging from removal of prior implants to aseptic loosening. As surgeons navigate these challenges, a reliable surgical system is important. One modular fluted tapered system provides surgeons with tools to address complex hip revision cases. Introduced in 2003, this system has been utilized in over 180,000 procedures, demonstrating its reliability and effectiveness. Previously, the body stem came in sizes 155mm to 235mm. In the discussed case series, we present six distinct patient cases that highlight the advantages and efficacy of a newly introduced modification of the system; that is the use of smaller stemmed components (now 115mm). With each patient presenting unique challenges, we have demonstrated the use of this new short-stem version for multiple applications for various revision scenarios.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modular Revision System for Complex Hip Revisions: A Case Series.\",\"authors\":\"Daniel Hameed, Brittany Oster, Bryan D Springer, Arthur L Malkani, Michael A Mont\",\"doi\":\"10.52198/24.STI.44.OS1757\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Revision total hip arthroplasty (THA) is a procedure with many challenges, especially when patients exhibit femoral bone defects. The causes of these defects vary, ranging from removal of prior implants to aseptic loosening. As surgeons navigate these challenges, a reliable surgical system is important. One modular fluted tapered system provides surgeons with tools to address complex hip revision cases. Introduced in 2003, this system has been utilized in over 180,000 procedures, demonstrating its reliability and effectiveness. Previously, the body stem came in sizes 155mm to 235mm. In the discussed case series, we present six distinct patient cases that highlight the advantages and efficacy of a newly introduced modification of the system; that is the use of smaller stemmed components (now 115mm). With each patient presenting unique challenges, we have demonstrated the use of this new short-stem version for multiple applications for various revision scenarios.</p>\",\"PeriodicalId\":22194,\"journal\":{\"name\":\"Surgical technology international\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical technology international\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52198/24.STI.44.OS1757\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/24.STI.44.OS1757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/1 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

翻修全髋关节置换术(THA)是一项充满挑战的手术,尤其是当患者出现股骨头缺损时。造成这些缺陷的原因多种多样,从先前植入物的移除到无菌性松动,不一而足。外科医生在应对这些挑战时,可靠的手术系统非常重要。一种模块化凹槽锥形系统为外科医生提供了处理复杂髋关节翻修病例的工具。该系统于2003年推出,已用于超过18万例手术,证明了其可靠性和有效性。以前,髋臼体柄的尺寸从155毫米到235毫米不等。在讨论的病例系列中,我们介绍了六个不同的患者病例,突出强调了新引进的系统改良的优势和有效性,即使用较小的柄部件(现在为 115 毫米)。由于每位患者都面临着独特的挑战,我们展示了这种新型短茎式组件在各种翻修情况下的多种应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Modular Revision System for Complex Hip Revisions: A Case Series.

Revision total hip arthroplasty (THA) is a procedure with many challenges, especially when patients exhibit femoral bone defects. The causes of these defects vary, ranging from removal of prior implants to aseptic loosening. As surgeons navigate these challenges, a reliable surgical system is important. One modular fluted tapered system provides surgeons with tools to address complex hip revision cases. Introduced in 2003, this system has been utilized in over 180,000 procedures, demonstrating its reliability and effectiveness. Previously, the body stem came in sizes 155mm to 235mm. In the discussed case series, we present six distinct patient cases that highlight the advantages and efficacy of a newly introduced modification of the system; that is the use of smaller stemmed components (now 115mm). With each patient presenting unique challenges, we have demonstrated the use of this new short-stem version for multiple applications for various revision scenarios.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
141
期刊最新文献
Robotic Assisted Lapendoscopic Single-Site Surgery for Ileal Deep Endometriosis. A Case Report and Review of Literature. Robotic versus Laparoscopic Partial Nephrectomy: A Systematic Review and Meta-Analysis of Randomised Trials. Cardiophrenic Lymph Node Resection Through Abdominal Subxiphoid Approach: Surgical Technique. What Happens to Endometriosis During the Menstrual Cycle? Robotic Total Knee Arthroplasty is Associated with Thinner and Less Constrained Polyethylene Inserts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1